title: "Solartech Energy ASC-6P-60-255 Specs (255.0W, 38.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-60-255/
description: "CEC datasheet for Solartech Energy ASC-6P-60-255: 255.0W STC, 38.2V Voc, 32-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Solartech Energy ASC-6P-60-255 — CEC Solar Module Specifications

Manufacturer: [**Solartech Energy**](https://epri-peac.com/solar-equipment/brands/solartech-energy/) Registry: **CEC Verified Engineering Specification**

Solartech Energy ASC-6P-60-255 is a 255.0 W STC (229.8 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.55% efficiency, 38.2 V Voc at 25 C, and 42.73 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 255.0 W

- **PTC Wattage** : 229.8 W

- **Voc @ 25C** : 38.2 V

- **Efficiency** : 15.55%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solartech Energy ASC-6P-60-255 Compare Against Peer CEC Listings?

Solar engineering breakdown for Solartech Energy ASC-6P-60-255: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Across 1,407 Multi-c-Si listings from Solartech Energy and peers, Solartech Energy ASC-6P-60-255 stands 23.8 W below the 278.8 W Multi-c-Si median and typical 90.1% PTC-to-STC thermal output (229.8 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (40 panels) yields $1,532-$2,553/yr in baseline US bill offset. Lower 38.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Solartech Energy ASC-6P-60-255 Fall Across Listed CEC Models?

Distribution marker showing Solartech Energy ASC-6P-60-255 (255.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define Solartech Energy ASC-6P-60-255?

Dataset percentiles tracking Solartech Energy ASC-6P-60-255 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for Solartech Energy ASC-6P-60-255?

Benchmark highlights for Solartech Energy ASC-6P-60-255 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #19,421 / 21,677

### 255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,853

### 15.55% Aperture Efficiency

Power density 155.5 W/m2 (4.36 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.73 V at -10 C (598.2 V string) and 44.03 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,160 W STC

Occupies 52.5 m2 (565 sq ft) producing 7,354 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.2 * (1 + (-0.339/100) * (-10 - 25)) = 42.73 V | OCPD = 1.56 * 8.66 = 13.51 A

Inputs from CEC Modules.csv for Solartech Energy ASC-6P-60-255: Voc=38.2 V, beta_Voc=-0.339%/C, Isc=8.66 A, STC=255.0 W, Area=1.64 m2.

**Result:** 14 panels max on 600 V (598.2 V); 32 panels for 8 kW (565 sq ft).

## What Are the Published CEC Specifications for Solartech Energy ASC-6P-60-255?

Official CEC datasheet figures for Solartech Energy ASC-6P-60-255 (Multi-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Solartech Energy ASC-6P-60-255.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 229.8 W (90.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.25 V / 8.16 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.339 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.55% (1.64 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Solartech Energy ASC-6P-60-255 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solartech Energy ASC-6P-60-255 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.12 kW | 424 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 32 | 8.16 kW | 565 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 40 | 10.2 kW | 706 sq ft | $2,553 | $4,317 |

## Which Sibling Wattage & Trim Variants Belong to This Solartech Energy Series?

Consolidated Solartech Energy wattage variants sharing the Solartech Energy ASC-6P-60-255 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Solartech Energy ASC-6P-60-255 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Solartech Energy ASC-6P-60-250** | 250.0 W | 225.3 W | 37.65 V | 30.83 V | 15.25% |
| **Solartech Energy ASC-6P-60-255** | 255.0 W | 229.8 W | 38.2 V | 31.25 V | 15.55% |

## How Many Solartech Energy ASC-6P-60-255 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Energy ASC-6P-60-255 (42.73 V at 14 F).

Computed from Voc=38.2V and beta_Voc=-0.339%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.03 V | 13 panels | 572.4 V | 22 panels |
| **-10 C (14 F)** | 42.73 V | 14 panels | 598.2 V | 23 panels |
| **0 C (32 F)** | 41.44 V | 14 panels | 580.2 V | 24 panels |
| **25 C (77 F STC)** | 38.2 V | 15 panels | 573.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6P-60-255?

Competing CEC solar panels closest to Solartech Energy ASC-6P-60-255 in nameplate wattage and Voc, starting with Changzhou Nesl Solartech DJ-255D/C-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Changzhou Nesl Solartech DJ-255D/C-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-255d-c-st15/) Changzhou Nesl Solartech | 255.0 W | Tie (0 W) | 38.19 V | 15.61% | 90.4% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60255**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60255/) GCL System Integration Technology Co Ltd | 255.0 W | Tie (0 W) | 37.7 V | 15.67% | 90.4% |
| [**Advance Power API-M255**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m255/) Advance Power | 255.0 W | Tie (0 W) | 37.68 V | 15.57% | 89.5% |
| [**Eoplly New Energy Technology EP156P/60-255S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156p-60-255s-ac/) Eoplly New Energy Technology | 255.0 W | Tie (0 W) | 37.68 V | 15.6% | 89.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6P-60-255?

Evaluate Solartech Energy ASC-6P-60-255 (255.0 W STC, 38.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6P-60-255 reaches 44.03 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 565 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (565 sq ft).
- 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6P-60-255 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Solartech Energy ASC-6P-60-255 8 kW Residential Fit

Needs 32 modules (565 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-255D/C-ST15.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Energy ASC-6P-60-255 by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Solartech Energy ASC-6P-60-255?

Multiplying Solartech Energy ASC-6P-60-255's 8.66 A short-circuit current by 1.56 equals 13.51 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Solartech Energy ASC-6P-60-255 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.73 V cold Voc at 14 F and handles 8.66 A Isc; string inverters cap Solartech Energy ASC-6P-60-255 at 14 panels on 600 V.

### Is Solartech Energy ASC-6P-60-255 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solartech Energy ASC-6P-60-255 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

## Related Pages

Compare Solartech Energy equipment, Changzhou Nesl Solartech DJ-255D/C-ST15 specs, utility payback rates, and NEC string calculators alongside Solartech Energy ASC-6P-60-255.

[All Solartech Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solartech-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solartech Energy

- [All Solartech Energy Specs](https://epri-peac.com/solar-equipment/brands/solartech-energy/)
- [Solartech Energy ASC-6M-72-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6m-72-330-3bb/)
- [Solartech Energy ASC-6M-72B-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6m-72b-330-3bb/)
- [Solartech Energy ASC-6M-72C-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6m-72c-330-3bb/)
- [Solartech Energy ASC-6P-72-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-72-330-3bb/)
- [Solartech Energy ASC-6P-72B-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-72b-330-3bb/)