title: "Solartech Energy ASC-6P-54-230 Specs (230.0W, 34.02V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-54-230/
description: "CEC datasheet for Solartech Energy ASC-6P-54-230: 230.0W STC, 34.02V Voc, 35-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Solartech Energy ASC-6P-54-230 — CEC Solar Module Specifications

Manufacturer: [**Solartech Energy**](https://epri-peac.com/solar-equipment/brands/solartech-energy/) Registry: **CEC Verified Engineering Specification**

Solartech Energy ASC-6P-54-230 is a 230.0 W STC (204.0 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 15.51% efficiency, 34.02 V Voc at 25 C, and 38.31 V cold Voc at -10 C (15 panels max per 600 V string).

- **STC Wattage** : 230.0 W

- **PTC Wattage** : 204.0 W

- **Voc @ 25C** : 34.02 V

- **Efficiency** : 15.51%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solartech Energy ASC-6P-54-230 Compare Against Peer CEC Listings?

Solar engineering breakdown for Solartech Energy ASC-6P-54-230: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Measured at 230.0 W STC and 204.0 W PTC, Solartech Energy ASC-6P-54-230 sits -155.0 W vs all-CEC median (below all-CEC median; higher than 4.7% of peers) among 21,677 listed modules. Power density reaches 155.1 W/m2 (4.40 percentage points below 19.91% CEC median). Lower 34.02 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 26 panels in series. Alternative peer Centrosolar America DP54 230 rates 230.0 W.

## Where Does Solartech Energy ASC-6P-54-230 Fall Across Listed CEC Models?

Distribution marker showing Solartech Energy ASC-6P-54-230 (230.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Dataset Percentiles Define Solartech Energy ASC-6P-54-230?

Dataset percentiles tracking Solartech Energy ASC-6P-54-230 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Do the Dataset Ranks Show for Solartech Energy ASC-6P-54-230?

Benchmark highlights for Solartech Energy ASC-6P-54-230 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #20,522 / 21,677

### 230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,904

### 15.51% Aperture Efficiency

Power density 155.1 W/m2 (4.40 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

### 15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.31 V at -10 C (574.7 V string) and 39.53 V at -20 C (15 max).

 8 kW Reference Array

### 35 Panels = 8,050 W STC

Occupies 51.9 m2 (559 sq ft) producing 7,140 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 34.02 * (1 + (-0.36/100) * (-10 - 25)) = 38.31 V | OCPD = 1.56 * 8.66 = 13.51 A

Inputs from CEC Modules.csv for Solartech Energy ASC-6P-54-230: Voc=34.02 V, beta_Voc=-0.36%/C, Isc=8.66 A, STC=230.0 W, Area=1.483 m2.

**Result:** 15 panels max on 600 V (574.7 V); 35 panels for 8 kW (559 sq ft).

## What Are the Published CEC Specifications for Solartech Energy ASC-6P-54-230?

Official CEC datasheet figures for Solartech Energy ASC-6P-54-230 (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Solartech Energy ASC-6P-54-230.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 230.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 204.0 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 34.02 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 28.19 V / 8.16 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.36 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.51% (1.483 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Solartech Energy ASC-6P-54-230 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solartech Energy ASC-6P-54-230 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 27 | 6.21 kW | 431 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 35 | 8.05 kW | 559 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 44 | 10.12 kW | 702 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Solartech Energy Series?

Consolidated Solartech Energy wattage variants sharing the Solartech Energy ASC-6P-54-230 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Solartech Energy ASC-6P-54-230 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Solartech Energy ASC-6P-54-225** | 225.0 W | 199.4 W | 33.8 V | 27.78 V | 15.17% |
| **Solartech Energy ASC-6P-54-230** | 230.0 W | 204.0 W | 34.02 V | 28.19 V | 15.51% |

## How Many Solartech Energy ASC-6P-54-230 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Energy ASC-6P-54-230 (38.31 V at 14 F).

Computed from Voc=34.02V and beta_Voc=-0.36%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 39.53 V | 15 panels | 593.0 V | 25 panels |
| **-10 C (14 F)** | 38.31 V | 15 panels | 574.7 V | 26 panels |
| **0 C (32 F)** | 37.08 V | 16 panels | 593.3 V | 26 panels |
| **25 C (77 F STC)** | 34.02 V | 17 panels | 578.3 V | 29 panels |

## Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6P-54-230?

Competing CEC solar panels closest to Solartech Energy ASC-6P-54-230 in nameplate wattage and Voc, starting with Centrosolar America DP54 230.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DP54 230**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp54-230/) Centrosolar America | 230.0 W | Tie (0 W) | 34.02 V | 15.51% | 88.7% |
| [**Gintung Energy ASEC-235G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-235g6m69/) Gintung Energy | 235.0 W | +5.0 W | 34.06 V | 16.04% | 88.1% |
| [**Gintung Energy GTEC-235G6M69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-235g6m69/) Gintung Energy | 235.0 W | +5.0 W | 34.06 V | 16.04% | 88.1% |
| [**Gintung Energy ASEC-235G6S69**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-235g6s69/) Gintung Energy | 235.0 W | +5.0 W | 34.13 V | 16.04% | 87.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6P-54-230?

Evaluate Solartech Energy ASC-6P-54-230 (230.0 W STC, 34.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6P-54-230 reaches 39.53 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 559 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (559 sq ft).
- 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6P-54-230 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Solartech Energy ASC-6P-54-230 8 kW Residential Fit

Needs 35 modules (559 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Centrosolar America DP54 230.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 204.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Energy ASC-6P-54-230 by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Solartech Energy ASC-6P-54-230 panels fit on a 600 V winter solar string?

At -10 C (14 F), Solartech Energy ASC-6P-54-230 cold Voc rises from 34.02 V to 38.31 V (beta_Voc -0.36%/C), capping a 600 V string at 15 panels (574.7 V).

### How much roof area does an 8 kW array of Solartech Energy ASC-6P-54-230 need?

An 8 kW DC system uses 35 Solartech Energy ASC-6P-54-230 modules (8,050 W STC / 7,140 W PTC), covering roughly 559 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

### How does Solartech Energy ASC-6P-54-230 compare against Centrosolar America DP54 230?

Solartech Energy ASC-6P-54-230 outputs 230.0 W STC (34.02 V Voc, rank #20,522 of 21,677), while Centrosolar America DP54 230 delivers 230.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Solartech Energy equipment, Centrosolar America DP54 230 specs, utility payback rates, and NEC string calculators alongside Solartech Energy ASC-6P-54-230.

[All Solartech Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solartech-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solartech Energy

- [All Solartech Energy Specs](https://epri-peac.com/solar-equipment/brands/solartech-energy/)
- [Solartech Energy ASC-6M-72-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6m-72-330-3bb/)
- [Solartech Energy ASC-6M-72B-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6m-72b-330-3bb/)
- [Solartech Energy ASC-6M-72C-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6m-72c-330-3bb/)
- [Solartech Energy ASC-6P-72-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-72-330-3bb/)
- [Solartech Energy ASC-6P-72B-330-3BB](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-72b-330-3bb/)