title: "Solaria Corporation Solaria Specs (420.0W, 52.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-420r-pm/
description: "CEC datasheet for Solaria Corporation Solaria PowerXT-420R-PM: 420.0W STC, 52.4V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Solaria Corporation Solaria PowerXT-420R-PM — CEC Solar Module Specifications

Manufacturer: [**Solaria Corporation**](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) Registry: **CEC Verified Engineering Specification**

Solaria Corporation Solaria PowerXT-420R-PM is a 420.0 W STC (383.0 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.21% efficiency, 52.4 V Voc at 25 C, and 58.4 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 383.0 W

- **Voc @ 25C** : 52.4 V

- **Efficiency** : 21.21%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solaria Corporation Solaria PowerXT-420R-PM Compare Against Peer CEC Listings?

How Solaria Corporation Solaria Corporation Solaria PowerXT-420R-PM handles rooftop heat (383.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Solaria Corporation Solaria PowerXT-420R-PM exhibits 9.94 A short-circuit current, requiring a 15.51 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #7,910 of 21,677 (10.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.6 m2 for an 8 kW system (24 panels for 10 kW). Higher 52.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does Solaria Corporation Solaria PowerXT-420R-PM Fall Across Listed CEC Models?

Where Solaria Corporation Solaria PowerXT-420R-PM (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-420R-PM?

Percentile placement of Solaria Corporation Solaria PowerXT-420R-PM across power density (212.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-420R-PM?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation Solaria PowerXT-420R-PM specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,556

### 21.21% Aperture Efficiency

Power density 212.1 W/m2 (1.30 percentage points above 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.4 V at -10 C (584.0 V string) and 60.11 V at -20 C (9 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,660 W PTC; NEC 690.8 OCPD floor is 15.51 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.4 * (1 + (-0.327/100) * (-10 - 25)) = 58.4 V | OCPD = 1.56 * 9.94 = 15.51 A

Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-420R-PM: Voc=52.4 V, beta_Voc=-0.327%/C, Isc=9.94 A, STC=420.0 W, Area=1.98 m2.

**Result:** 10 panels max on 600 V (584.0 V); 20 panels for 8 kW (426 sq ft).

## What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-420R-PM?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation Solaria PowerXT-420R-PM.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation Solaria PowerXT-420R-PM.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 383.0 W (91.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 43.8 V / 9.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.327 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.21% (1.98 m2) | Array roof footprint density |
| **Cell Count & Technology** | 380 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Solaria Corporation Solaria PowerXT-420R-PM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation Solaria PowerXT-420R-PM (420.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 320 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 426 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 512 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?

All closely matched Solaria Corporation wattages and cosmetic trims sharing the Solaria Corporation Solaria PowerXT-420R-PM architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Solaria Corporation Solaria PowerXT-420R-PM wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Solaria Corporation Solaria PowerXT-410R-PM** | 410.0 W | 373.6 W | 51.7 V | 43.2 V | 20.71% |
| **Solaria Corporation Solaria PowerXT-420R-PM** | 420.0 W | 383.0 W | 52.4 V | 43.8 V | 21.21% |

## How Many Solaria Corporation Solaria PowerXT-420R-PM Modules Fit in a Cold-Weather String?

Maximum series module counts for Solaria Corporation Solaria PowerXT-420R-PM from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.4V and beta_Voc=-0.327%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 60.11 V | 9 panels | 541.0 V | 16 panels |
| **-10 C (14 F)** | 58.4 V | 10 panels | 584.0 V | 17 panels |
| **0 C (32 F)** | 56.68 V | 10 panels | 566.8 V | 17 panels |
| **25 C (77 F STC)** | 52.4 V | 11 panels | 576.4 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-420R-PM?

Alternative CEC solar modules from competing brands near Solaria Corporation Solaria PowerXT-420R-PM (420.0 W), including CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS1Y-410MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-410ms/) CSI Solar Co Ltd | 410.0 W | -10.0 W | 52.7 V | 21.03% | 94.1% |
| [**DualSun SAS DualSun 420M-144-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-420m-144-01/) DualSun SAS | 420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| [**Auxin Solar AXNG1M410B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410b/) Auxin Solar | 410.0 W | -10.0 W | 49.47 V | 20.92% | 93.4% |
| [**Auxin Solar AXNG1M410W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410w/) Auxin Solar | 410.0 W | -10.0 W | 49.47 V | 20.92% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-420R-PM?

Evaluate Solaria Corporation Solaria PowerXT-420R-PM (420.0 W STC, 52.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-420R-PM reaches 60.11 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-420R-PM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Solaria Corporation Solaria PowerXT-420R-PM 8 kW Residential Fit

Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solaria Corporation Solaria PowerXT-420R-PM by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Solaria Corporation Solaria PowerXT-420R-PM PTC wattage (383.0 W) lower than STC (420.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 383.0 W PTC (91.2% retention) across Solaria Corporation Solaria PowerXT-420R-PM's 1.98 m2 aperture.

### Who should skip Solaria Corporation Solaria PowerXT-420R-PM on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Solaria Corporation Solaria PowerXT-420R-PM panels (426 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-410MS.

### What is the 1,000 V commercial string limit for Solaria Corporation Solaria PowerXT-420R-PM?

On 1,000 V commercial inverters at -10 C (58.4 V cold Voc), Solaria Corporation Solaria PowerXT-420R-PM fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation Solaria PowerXT-420R-PM.

## Related Pages

Compare Solaria Corporation equipment, CSI Solar Co Ltd CS1Y-410MS specs, utility payback rates, and NEC string calculators alongside Solaria Corporation Solaria PowerXT-420R-PM.

[All Solaria Corporation Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solaria Corporation

- [All Solaria Corporation Specs](https://epri-peac.com/solar-equipment/brands/solaria-corporation/)
- [Solaria Corporation PowerXT-430R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-430r-pl/)
- [Solaria Corporation PowerXT-420R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-420r-pl/)
- [Solaria Corporation Solaria PowerXT-410R-PM-AC](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-410r-pm-ac/)
- [Solaria Corporation PowerX-405R](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerx-405r/)
- [Solaria Corporation PowerX-405R-4T](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerx-405r-4t/)