title: "Solaria Corporation Solaria Specs (405.0W, 51.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-405r-pm/
description: "CEC datasheet for Solaria Corporation Solaria PowerXT-405R-PM: 405.0W STC, 51.4V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Solaria Corporation Solaria PowerXT-405R-PM — CEC Solar Module Specifications

Manufacturer: [**Solaria Corporation**](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) Registry: **CEC Verified Engineering Specification**

Solaria Corporation Solaria PowerXT-405R-PM is a 405.0 W STC (368.8 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.45% efficiency, 51.4 V Voc at 25 C, and 57.28 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 368.8 W

- **Voc @ 25C** : 51.4 V

- **Efficiency** : 20.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solaria Corporation Solaria PowerXT-405R-PM Compare Against Peer CEC Listings?

Engineering position of Solaria Corporation Solaria PowerXT-405R-PM (405.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-405L-H across 5,889 CEC Mono-c-Si solar modules.

Ranking #8,961 across 21,677 CEC solar panels (top 43.4%; higher than 56.6% of peers), Solaria Corporation Solaria PowerXT-405R-PM operates as a modern high-density residential and light-commercial module sitting 5.0 W below the 410.0 W Mono-c-Si median. Higher 51.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With typical 91.1% PTC-to-STC thermal output (368.8 W real-world rating), 20 panels occupy 426 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Solaria Corporation Solaria PowerXT-405R-PM Fall Across Listed CEC Models?

Plots Solaria Corporation Solaria PowerXT-405R-PM at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-405R-PM?

Benchmarks Solaria Corporation Solaria PowerXT-405R-PM on STC wattage, thermal PTC/STC retention, and 20.45 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-405R-PM?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Solaria Corporation Solaria PowerXT-405R-PM by Solaria Corporation.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,829

### 20.45% Aperture Efficiency

Power density 204.5 W/m2 (0.54 percentage points above 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.28 V at -10 C (572.8 V string) and 58.96 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,376 W PTC; NEC 690.8 OCPD floor is 15.37 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.4 * (1 + (-0.327/100) * (-10 - 25)) = 57.28 V | OCPD = 1.56 * 9.85 = 15.37 A

Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-405R-PM: Voc=51.4 V, beta_Voc=-0.327%/C, Isc=9.85 A, STC=405.0 W, Area=1.98 m2.

**Result:** 10 panels max on 600 V (572.8 V); 20 panels for 8 kW (426 sq ft).

## What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-405R-PM?

Laboratory test ratings recorded for Solaria Corporation Solaria PowerXT-405R-PM (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation Solaria PowerXT-405R-PM.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 368.8 W (91.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 51.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.8 V / 9.46 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.327 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.45% (1.98 m2) | Array roof footprint density |
| **Cell Count & Technology** | 38 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Solaria Corporation Solaria PowerXT-405R-PM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (426 sq ft at 8 kW), and estimated Year-1 electric bill offset for Solaria Corporation Solaria PowerXT-405R-PM.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 320 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 426 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 533 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?

Sibling wattage bins and frame colors grouped with Solaria Corporation Solaria PowerXT-405R-PM under Solaria Corporation to prevent duplicate spec pages.

Sibling CEC listings grouped into the Solaria Corporation Solaria PowerXT-405R-PM wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Solaria Corporation Solaria PowerXT-400R-PM** | 400.0 W | 364.1 W | 51.1 V | 42.4 V | 20.2% |
| **Solaria Corporation Solaria PowerXT-405R-PM** | 405.0 W | 368.8 W | 51.4 V | 42.8 V | 20.45% |
| **Solaria Corporation Solaria PowerXT-415R-PM** | 415.0 W | 378.3 W | 52.1 V | 43.5 V | 20.96% |

## How Many Solaria Corporation Solaria PowerXT-405R-PM Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Solaria Corporation Solaria PowerXT-405R-PM (beta_Voc -0.327%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=51.4V and beta_Voc=-0.327%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.96 V | 10 panels | 589.6 V | 16 panels |
| **-10 C (14 F)** | 57.28 V | 10 panels | 572.8 V | 17 panels |
| **0 C (32 F)** | 55.6 V | 10 panels | 556.0 V | 17 panels |
| **25 C (77 F STC)** | 51.4 V | 11 panels | 565.4 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-405R-PM?

Closest cross-brand CEC competitors to Solaria Corporation Solaria PowerXT-405R-PM matched near 405.0 W STC and 51.4 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-405L-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.35% | 93.3% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 19.95% | 93.6% |
| [**CSI Solar Co Ltd CS3U-405MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-405ms/) CSI Solar Co Ltd | 405.0 W | Tie (0 W) | 49.3 V | 21.09% | 93.0% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-hc-405w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 405.0 W | Tie (0 W) | 49.2 V | 21.2% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-405R-PM?

Evaluate Solaria Corporation Solaria PowerXT-405R-PM (405.0 W STC, 51.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-405R-PM reaches 58.96 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-405R-PM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Solaria Corporation Solaria PowerXT-405R-PM 8 kW Residential Fit

Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solaria Corporation Solaria PowerXT-405R-PM by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Solaria Corporation Solaria PowerXT-405R-PM panels fit on a 600 V winter solar string?

At -10 C (14 F), Solaria Corporation Solaria PowerXT-405R-PM cold Voc rises from 51.4 V to 57.28 V (beta_Voc -0.327%/C), capping a 600 V string at 10 panels (572.8 V).

### How much roof area does an 8 kW array of Solaria Corporation Solaria PowerXT-405R-PM need?

An 8 kW DC system uses 20 Solaria Corporation Solaria PowerXT-405R-PM modules (8,100 W STC / 7,376 W PTC), covering roughly 426 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does Solaria Corporation Solaria PowerXT-405R-PM compare against Boviet Solar Technology Co Ltd BVM6612M-405L-H?

Solaria Corporation Solaria PowerXT-405R-PM outputs 405.0 W STC (51.4 V Voc, rank #8,961 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-405L-H delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Solaria Corporation equipment, Boviet Solar Technology Co Ltd BVM6612M-405L-H specs, utility payback rates, and NEC string calculators alongside Solaria Corporation Solaria PowerXT-405R-PM.

[All Solaria Corporation Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solaria Corporation

- [All Solaria Corporation Specs](https://epri-peac.com/solar-equipment/brands/solaria-corporation/)
- [Solaria Corporation PowerXT-430R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-430r-pl/)
- [Solaria Corporation PowerXT-420R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-420r-pl/)
- [Solaria Corporation Solaria PowerXT-420R-PM](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-420r-pm/)
- [Solaria Corporation Solaria PowerXT-410R-PM-AC](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-410r-pm-ac/)
- [Solaria Corporation PowerX-405R](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerx-405r/)