# Solaria Corporation Solaria PowerXT-360R-PD-L — CEC Solar Module Specifications

Manufacturer: [**Solaria Corporation**](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) Registry: **CEC Verified Engineering Specification**

Solaria Corporation Solaria PowerXT-360R-PD-L is a 360.0 W STC (327.6 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.89% efficiency, 47.7 V Voc at 25 C, and 52.86 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 360.0 W

- **PTC Wattage** : 327.6 W

- **Voc @ 25C** : 47.7 V

- **Efficiency** : 19.89%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solaria Corporation Solaria PowerXT-360R-PD-L Compare Against Peer CEC Listings?

Engineering position of Solaria Corporation Solaria PowerXT-360R-PD-L (360.0 W STC) vs. Advance Power API-M360 across 5,889 CEC Mono-c-Si solar modules.

Ranking #12,385 across 21,677 CEC solar panels (below all-CEC median; higher than 41.3% of peers), Solaria Corporation Solaria PowerXT-360R-PD-L operates as a compact residential or specialty off-grid module sitting 50.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With typical 91.0% PTC-to-STC thermal output (327.6 W real-world rating), 23 panels occupy 448 sq ft and offset roughly $2,072/yr at average US rates (or $3,504/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Solaria Corporation Solaria PowerXT-360R-PD-L Fall Across Listed CEC Models?

Plots Solaria Corporation Solaria PowerXT-360R-PD-L at 360.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-360R-PD-L?

Benchmarks Solaria Corporation Solaria PowerXT-360R-PD-L on STC wattage, thermal PTC/STC retention, and 19.89 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-360R-PD-L?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Solaria Corporation Solaria PowerXT-360R-PD-L by Solaria Corporation.

Rank #12,385 / 21,677

### 360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,917

### 19.89% Aperture Efficiency

Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.86 V at -10 C (581.5 V string) and 54.33 V at -20 C (11 max).

 8 kW Reference Array

### 23 Panels = 8,280 W STC

Occupies 41.6 m2 (448 sq ft) producing 7,535 W PTC; NEC 690.8 OCPD floor is 14.91 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.7 * (1 + (-0.309/100) * (-10 - 25)) = 52.86 V | OCPD = 1.56 * 9.56 = 14.91 A

Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-360R-PD-L: Voc=47.7 V, beta_Voc=-0.309%/C, Isc=9.56 A, STC=360.0 W, Area=1.81 m2.

**Result:** 11 panels max on 600 V (581.5 V); 23 panels for 8 kW (448 sq ft).

## What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-360R-PD-L?

Laboratory test ratings recorded for Solaria Corporation Solaria PowerXT-360R-PD-L (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation Solaria PowerXT-360R-PD-L.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 327.6 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 39.5 V / 9.13 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.309 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.89% (1.81 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Solaria Corporation Solaria PowerXT-360R-PD-L Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (448 sq ft at 8 kW), and estimated Year-1 electric bill offset for Solaria Corporation Solaria PowerXT-360R-PD-L.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.12 kW | 331 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 23 | 8.28 kW | 448 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 28 | 10.08 kW | 546 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?

Sibling wattage bins and frame colors grouped with Solaria Corporation Solaria PowerXT-360R-PD-L under Solaria Corporation to prevent duplicate spec pages.

Sibling CEC listings grouped into the Solaria Corporation Solaria PowerXT-360R-PD-L wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Solaria Corporation Solaria PowerXT-355R-PD-L** | 355.0 W | 322.9 W | 47.4 V | 39.1 V | 19.61% |
| **Solaria Corporation Solaria PowerXT-360R-PD-L** | 360.0 W | 327.6 W | 47.7 V | 39.5 V | 19.89% |
| **Solaria Corporation Solaria PowerXT-365R-PD-L** | 365.0 W | 332.4 W | 48.0 V | 39.9 V | 20.17% |

## How Many Solaria Corporation Solaria PowerXT-360R-PD-L Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Solaria Corporation Solaria PowerXT-360R-PD-L (beta_Voc -0.309%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.7V and beta_Voc=-0.309%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.33 V | 11 panels | 597.6 V | 18 panels |
| **-10 C (14 F)** | 52.86 V | 11 panels | 581.5 V | 18 panels |
| **0 C (32 F)** | 51.38 V | 11 panels | 565.2 V | 19 panels |
| **25 C (77 F STC)** | 47.7 V | 12 panels | 572.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-360R-PD-L?

Closest cross-brand CEC competitors to Solaria Corporation Solaria PowerXT-360R-PD-L matched near 360.0 W STC and 47.7 V Voc, led by Advance Power API-M360.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-M360**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m360/) Advance Power | 360.0 W | Tie (0 W) | 47.56 V | 18.56% | 91.7% |
| [**Auxin Solar AXN6M612T360**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t360/) Auxin Solar | 360.0 W | Tie (0 W) | 47.56 V | 18.55% | 91.7% |
| [**Boviet Solar Technology Co Ltd BVM6612M-360**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-360/) Boviet Solar Technology Co Ltd | 360.0 W | Tie (0 W) | 47.5 V | 18.56% | 92.3% |
| [**Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development-co-ltd/anhui-rinengzhongtian-semiconductor-development-co-ltd-qjm360-72/) Anhui Rinengzhongtian Semiconductor Development Co Ltd | 360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-360R-PD-L?

Evaluate Solaria Corporation Solaria PowerXT-360R-PD-L (360.0 W STC, 47.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-360R-PD-L reaches 54.33 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft).
- 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-360R-PD-L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Solaria Corporation Solaria PowerXT-360R-PD-L 8 kW Residential Fit

Needs 23 modules (448 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M360.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 327.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solaria Corporation Solaria PowerXT-360R-PD-L by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Solaria Corporation Solaria PowerXT-360R-PD-L panels fit on a 600 V winter solar string?

At -10 C (14 F), Solaria Corporation Solaria PowerXT-360R-PD-L cold Voc rises from 47.7 V to 52.86 V (beta_Voc -0.309%/C), capping a 600 V string at 11 panels (581.5 V).

### How much roof area does an 8 kW array of Solaria Corporation Solaria PowerXT-360R-PD-L need?

An 8 kW DC system uses 23 Solaria Corporation Solaria PowerXT-360R-PD-L modules (8,280 W STC / 7,535 W PTC), covering roughly 448 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

### How does Solaria Corporation Solaria PowerXT-360R-PD-L compare against Advance Power API-M360?

Solaria Corporation Solaria PowerXT-360R-PD-L outputs 360.0 W STC (47.7 V Voc, rank #12,385 of 21,677), while Advance Power API-M360 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Solaria Corporation equipment, Advance Power API-M360 specs, utility payback rates, and NEC string calculators alongside Solaria Corporation Solaria PowerXT-360R-PD-L.

[All Solaria Corporation Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solaria Corporation

- [All Solaria Corporation Specs](https://epri-peac.com/solar-equipment/brands/solaria-corporation/)
- [Solaria Corporation PowerXT-430R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-430r-pl/)
- [Solaria Corporation PowerXT-420R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-420r-pl/)
- [Solaria Corporation Solaria PowerXT-420R-PM](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-420r-pm/)
- [Solaria Corporation Solaria PowerXT-410R-PM-AC](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-410r-pm-ac/)
- [Solaria Corporation PowerX-405R](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerx-405r/)