# Solaria Corporation PowerX-405R — CEC Solar Module Specifications

Manufacturer: [**Solaria Corporation**](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) Registry: **CEC Verified Engineering Specification**

Solaria Corporation PowerX-405R is a 405.0 W STC (369.6 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.77% efficiency, 37.36 V Voc at 25 C, and 40.92 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 369.6 W

- **Voc @ 25C** : 37.36 V

- **Efficiency** : 20.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solaria Corporation PowerX-405R Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Solaria Corporation PowerX-405R (Mono-c-Si) residential solar systems.

Homeowners evaluating Solaria Corporation PowerX-405R need 15 panels for 6 kW or 20 panels (420 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.272%/C) pushes open-circuit voltage to 40.92 V at 14 F and 41.93 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Solaria Corporation PowerX-405R Fall Across Listed CEC Models?

Comparison of Solaria Corporation PowerX-405R (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define Solaria Corporation PowerX-405R?

Relative ranking of Solaria Corporation PowerX-405R across nameplate watts, 91.3% PTC thermal ratio, and module aperture efficiency. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Do the Dataset Ranks Show for Solaria Corporation PowerX-405R?

Summary of Solaria Corporation PowerX-405R output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,352

### 20.77% Aperture Efficiency

Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.92 V at -10 C (572.9 V string) and 41.93 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 21.5 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.36 * (1 + (-0.272/100) * (-10 - 25)) = 40.92 V | OCPD = 1.56 * 13.78 = 21.5 A

Inputs from CEC Modules.csv for Solaria Corporation PowerX-405R: Voc=37.36 V, beta_Voc=-0.272%/C, Isc=13.78 A, STC=405.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (572.9 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for Solaria Corporation PowerX-405R?

Complete CEC test sheet for Solaria Corporation PowerX-405R including Isc (13.78 A), Voc (37.36 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation PowerX-405R.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 369.6 W (91.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.36 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.36 V / 12.92 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.272 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.77% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 12 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Solaria Corporation PowerX-405R Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Solaria Corporation PowerX-405R.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 315 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 420 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 525 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?

Related Solaria Corporation power steps and black/silver trims consolidated into this Solaria Corporation PowerX-405R series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Solaria Corporation PowerX-405R wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Solaria Corporation PowerX-400R** | 400.0 W | 364.9 W | 37.2 V | 31.17 V | 20.51% |
| **Solaria Corporation PowerX-405R** | 405.0 W | 369.6 W | 37.36 V | 31.36 V | 20.77% |

## How Many Solaria Corporation PowerX-405R Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Solaria Corporation PowerX-405R (37.36 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.36V and beta_Voc=-0.272%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.93 V | 14 panels | 587.0 V | 23 panels |
| **-10 C (14 F)** | 40.92 V | 14 panels | 572.9 V | 24 panels |
| **0 C (32 F)** | 39.9 V | 15 panels | 598.5 V | 25 panels |
| **25 C (77 F STC)** | 37.36 V | 16 panels | 597.8 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation PowerX-405R?

Four comparable CEC modules such as Convalt Manufacturing LLC CVLT405-108M-BB (405.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Convalt Manufacturing LLC CVLT405-108M-BB**](https://epri-peac.com/solar-equipment/modules/convalt-manufacturing-llc/convalt-manufacturing-llc-cvlt405-108m-bb/) Convalt Manufacturing LLC | 405.0 W | Tie (0 W) | 37.36 V | 20.88% | 92.0% |
| [**Alexus Solar ALEX-405-B-54-S**](https://epri-peac.com/solar-equipment/modules/alexus-solar/alexus-solar-alex-405-b-54-s/) Alexus Solar | 405.0 W | Tie (0 W) | 37.38 V | 20.77% | 92.5% |
| [**AMPS Solar AMPS-405P-54BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-405p-54bb/) AMPS Solar | 405.0 W | Tie (0 W) | 37.25 V | 20.88% | 94.2% |
| [**CertainTeed CTM10405HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10405hc11-06/) CertainTeed | 405.0 W | Tie (0 W) | 37.23 V | 20.77% | 93.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Solaria Corporation PowerX-405R?

Evaluate Solaria Corporation PowerX-405R (405.0 W STC, 37.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation PowerX-405R reaches 41.93 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Solaria Corporation PowerX-405R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Solaria Corporation PowerX-405R 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Convalt Manufacturing LLC CVLT405-108M-BB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solaria Corporation PowerX-405R by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Solaria Corporation PowerX-405R PTC wattage (369.6 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 369.6 W PTC (91.3% retention) across Solaria Corporation PowerX-405R's 1.95 m2 aperture.

### Who should skip Solaria Corporation PowerX-405R on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Solaria Corporation PowerX-405R panels (420 sq ft) leave unusable roof gaps vs. Convalt Manufacturing LLC CVLT405-108M-BB.

### What is the 1,000 V commercial string limit for Solaria Corporation PowerX-405R?

On 1,000 V commercial inverters at -10 C (40.92 V cold Voc), Solaria Corporation PowerX-405R fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation PowerX-405R.

## Related Pages

Compare Solaria Corporation equipment, Convalt Manufacturing LLC CVLT405-108M-BB specs, utility payback rates, and NEC string calculators alongside Solaria Corporation PowerX-405R.

[All Solaria Corporation Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solaria-corporation/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solaria Corporation

- [All Solaria Corporation Specs](https://epri-peac.com/solar-equipment/brands/solaria-corporation/)
- [Solaria Corporation PowerXT-430R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-430r-pl/)
- [Solaria Corporation PowerXT-420R-PL](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerxt-420r-pl/)
- [Solaria Corporation Solaria PowerXT-420R-PM](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-420r-pm/)
- [Solaria Corporation Solaria PowerXT-410R-PM-AC](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-solaria-powerxt-410r-pm-ac/)
- [Solaria Corporation PowerX-405R-4T](https://epri-peac.com/solar-equipment/modules/solaria-corporation/solaria-corporation-powerx-405r-4t/)