# SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 — CEC Solar Module Specifications

Manufacturer: [**SOLAREVER TECNOLOG A DE AMERICA SA DE CV**](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) Registry: **CEC Verified Engineering Specification**

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 is a 555.0 W STC (516.0 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.68% efficiency, 50.18 V Voc at 25 C, and 55.19 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 555.0 W

- **PTC Wattage** : 516.0 W

- **Voc @ 25C** : 50.18 V

- **Efficiency** : 21.68%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 (Mono-c-Si) residential solar systems.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 delivers 216.8 W/m2 (1.77 percentage points above 19.91% CEC median) and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 56.62 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Bluesun Solar CoLtd BSM555M10-72HPH (555.0 W).

## Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 Fall Across Listed CEC Models?

Comparison of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 (555.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144?

Relative ranking of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144?

Summary of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,550 / 21,677

### Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,913

### 21.68% Aperture Efficiency

Power density 216.8 W/m2 (1.77 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.19 V at -10 C (551.9 V string) and 56.62 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,325 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,740 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.18 * (1 + (-0.285/100) * (-10 - 25)) = 55.19 V | OCPD = 1.56 * 13.73 = 21.42 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144: Voc=50.18 V, beta_Voc=-0.285%/C, Isc=13.73 A, STC=555.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (551.9 V); 15 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144?

Complete CEC test sheet for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 including Isc (13.73 A), Voc (50.18 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 516.0 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.01 V / 13.21 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.285 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.68% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.11 kW | 303 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 15 | 8.32 kW | 413 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 19 | 10.54 kW | 524 sq ft | $2,638 | $4,461 |

## Which Sibling Wattage & Trim Variants Belong to This SOLAREVER TECNOLOG A DE AMERICA SA DE CV Series?

Related SOLAREVER TECNOLOG A DE AMERICA SA DE CV power steps and black/silver trims consolidated into this SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 series guide.

Sibling CEC listings grouped into the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-550M-144** | 550.0 W | 511.2 W | 49.98 V | 41.86 V | 21.48% |
| **SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144** | 555.0 W | 516.0 W | 50.18 V | 42.01 V | 21.68% |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 (50.18 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.18V and beta_Voc=-0.285%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.62 V | 10 panels | 566.2 V | 17 panels |
| **-10 C (14 F)** | 55.19 V | 10 panels | 551.9 V | 18 panels |
| **0 C (32 F)** | 53.76 V | 11 panels | 591.4 V | 18 panels |
| **25 C (77 F STC)** | 50.18 V | 11 panels | 552.0 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144?

Four comparable CEC modules such as Bluesun Solar CoLtd BSM555M10-72HPH (555.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Bluesun Solar CoLtd BSM555M10-72HPH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm555m10-72hph/) Bluesun Solar CoLtd | 555.0 W | Tie (0 W) | 50.08 V | 21.42% | 93.3% |
| [**G-Star Pte Ltd GSD7G72M-555BT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd7g72m-555bt/) G-Star Pte Ltd | 555.0 W | Tie (0 W) | 50.08 V | 21.68% | 94.3% |
| [**G-Star Pte Ltd GSD7G72M-555WT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd7g72m-555wt/) G-Star Pte Ltd | 555.0 W | Tie (0 W) | 50.08 V | 21.68% | 94.3% |
| [**AXITEC AC-555MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mh-144v/) AXITEC | 555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 (555.0 W STC, 50.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 reaches 56.62 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM555M10-72HPH.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 516.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

### How many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 panels fit on a 600 V winter solar string?

At -10 C (14 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 cold Voc rises from 50.18 V to 55.19 V (beta_Voc -0.285%/C), capping a 600 V string at 10 panels (551.9 V).

### How much roof area does an 8 kW array of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 need?

An 8 kW DC system uses 15 SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 modules (8,325 W STC / 7,740 W PTC), covering roughly 413 sq ft and saving ~$2,082/yr at 18.54 c/kWh.

### How does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 compare against Bluesun Solar CoLtd BSM555M10-72HPH?

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144 outputs 555.0 W STC (50.18 V Voc, rank #2,550 of 21,677), while Bluesun Solar CoLtd BSM555M10-72HPH delivers 555.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare SOLAREVER TECNOLOG A DE AMERICA SA DE CV equipment, Bluesun Solar CoLtd BSM555M10-72HPH specs, utility payback rates, and NEC string calculators alongside SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144.

[All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLAREVER TECNOLOG A DE AMERICA SA DE CV

- [All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Specs](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-545m-144/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-460m-120-bh/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-455M-144N](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-166-83-455m-144n/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-450m-96-bd/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-445m-96-bd/)