title: "SOLAREVER TECNOLOG A DE AMERICA Specs (545.0W, 49.78V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-545m-144/
description: "CEC datasheet for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144: 545.0W STC, 49.78V Voc, 15-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 — CEC Solar Module Specifications

Manufacturer: [**SOLAREVER TECNOLOG A DE AMERICA SA DE CV**](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) Registry: **CEC Verified Engineering Specification**

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 is a 545.0 W STC (506.4 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.29% efficiency, 49.78 V Voc at 25 C, and 54.75 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 545.0 W

- **PTC Wattage** : 506.4 W

- **Voc @ 25C** : 49.78 V

- **Efficiency** : 21.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Compare Against Peer CEC Listings?

How SOLAREVER TECNOLOG A DE AMERICA SA DE CV SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 handles rooftop heat (506.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 exhibits 13.59 A short-circuit current, requiring a 21.2 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,998 of 21,677 (135.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.4 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.78 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Fall Across Listed CEC Models?

Where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Percentile placement of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 across power density (212.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 specifications.

Rank #2,998 / 21,677

### Top 15.1% STC Output

545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,168

### 21.29% Aperture Efficiency

Power density 212.9 W/m2 (1.38 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.75 V at -10 C (547.5 V string) and 56.16 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,175 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,596 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.78 * (1 + (-0.285/100) * (-10 - 25)) = 54.75 V | OCPD = 1.56 * 13.59 = 21.2 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144: Voc=49.78 V, beta_Voc=-0.285%/C, Isc=13.59 A, STC=545.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (547.5 V); 15 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 545.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 506.4 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.78 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.7 V / 13.07 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.285 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.29% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.54 kW | 331 sq ft | $1,637 | $2,768 |
| **8 kW Class** | 15 | 8.18 kW | 413 sq ft | $2,047 | $3,462 |
| **10 kW Class** | 19 | 10.36 kW | 524 sq ft | $2,593 | $4,385 |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.78V and beta_Voc=-0.285%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.16 V | 10 panels | 561.6 V | 17 panels |
| **-10 C (14 F)** | 54.75 V | 10 panels | 547.5 V | 18 panels |
| **0 C (32 F)** | 53.33 V | 11 panels | 586.6 V | 18 panels |
| **25 C (77 F STC)** | 49.78 V | 12 panels | 597.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Alternative CEC solar modules from competing brands near SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W), including Exiom Solution S A EX550-144MH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Exiom Solution S A EX550-144MH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144mh/) Exiom Solution S A | 545.0 W | Tie (0 W) | 49.8 V | 21.46% | 92.5% |
| [**Alexus Solar ALEX-545-B-72-S**](https://epri-peac.com/solar-equipment/modules/alexus-solar/alexus-solar-alex-545-b-72-s/) Alexus Solar | 545.0 W | Tie (0 W) | 49.68 V | 21.12% | 92.6% |
| [**Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545**](https://epri-peac.com/solar-equipment/modules/jiangsu-runergy-new-energy-technology-co-ltd/jiangsu-runergy-new-energy-technology-co-ltd-hy-dh144n8-545/) Jiangsu Runergy New Energy Technology Co Ltd | 545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
| [**Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545**](https://epri-peac.com/solar-equipment/modules/jiangsu-runergy-new-energy-technology-co-ltd/jiangsu-runergy-new-energy-technology-co-ltd-hy-dh144n8b-545-2/) Jiangsu Runergy New Energy Technology Co Ltd | 545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 (545.0 W STC, 49.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 reaches 56.16 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Exiom Solution S A EX550-144MH.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 506.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 PTC wattage (506.4 W) lower than STC (545.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 506.4 W PTC (92.9% retention) across SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144's 2.56 m2 aperture.

### Who should skip SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 panels (413 sq ft) leave unusable roof gaps vs. Exiom Solution S A EX550-144MH.

### What is the 1,000 V commercial string limit for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144?

On 1,000 V commercial inverters at -10 C (54.75 V cold Voc), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144 fits up to 18 panels per series string.

## Related Pages

Compare SOLAREVER TECNOLOG A DE AMERICA SA DE CV equipment, Exiom Solution S A EX550-144MH specs, utility payback rates, and NEC string calculators alongside SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144.

[All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLAREVER TECNOLOG A DE AMERICA SA DE CV

- [All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Specs](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-555m-144/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-460m-120-bh/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-455M-144N](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-166-83-455m-144n/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-450m-96-bd/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-445m-96-bd/)