title: "SOLAREVER TECNOLOG A DE AMERICA Specs (460.0W, 41.88V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-460m-120-bh/
description: "CEC datasheet for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH: 460.0W STC, 41.88V Voc, 18-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH — CEC Solar Module Specifications

Manufacturer: [**SOLAREVER TECNOLOG A DE AMERICA SA DE CV**](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) Registry: **CEC Verified Engineering Specification**

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH is a 460.0 W STC (428.2 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.5% efficiency, 41.88 V Voc at 25 C, and 45.78 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 460.0 W

- **PTC Wattage** : 428.2 W

- **Voc @ 25C** : 41.88 V

- **Efficiency** : 21.5%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH (Mono-c-Si) residential solar systems.

Homeowners evaluating SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH need 14 panels for 6 kW or 18 panels (415 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 45.78 V at 14 F and 46.89 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH Fall Across Listed CEC Models?

Comparison of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH?

Relative ranking of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH across nameplate watts, 93.1% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH?

Summary of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,199 / 21,677

### Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,451

### 21.5% Aperture Efficiency

Power density 215.0 W/m2 (1.59 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.78 V at -10 C (595.1 V string) and 46.89 V at -20 C (12 max).

 8 kW Reference Array

### 18 Panels = 8,280 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,708 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.88 * (1 + (-0.266/100) * (-10 - 25)) = 45.78 V | OCPD = 1.56 * 13.73 = 21.42 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH: Voc=41.88 V, beta_Voc=-0.266%/C, Isc=13.73 A, STC=460.0 W, Area=2.14 m2.

**Result:** 13 panels max on 600 V (595.1 V); 18 panels for 8 kW (415 sq ft).

## What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH?

Complete CEC test sheet for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH including Isc (13.73 A), Voc (41.88 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 428.2 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.88 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.82 V / 13.21 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.266 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.5% (2.14 m2) | Array roof footprint density |
| **Cell Count & Technology** | 40 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.44 kW | 322 sq ft | $1,612 | $2,726 |
| **8 kW Class** | 18 | 8.28 kW | 415 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 22 | 10.12 kW | 507 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This SOLAREVER TECNOLOG A DE AMERICA SA DE CV Series?

Related SOLAREVER TECNOLOG A DE AMERICA SA DE CV power steps and black/silver trims consolidated into this SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH series guide.

Sibling CEC listings grouped into the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-450M-120-BH** | 450.0 W | 418.6 W | 41.48 V | 34.43 V | 21.03% |
| **SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-455M-120-BH** | 455.0 W | 423.4 W | 41.68 V | 34.63 V | 21.26% |
| **SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH** | 460.0 W | 428.2 W | 41.88 V | 34.82 V | 21.5% |
| **SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-465M-120-BH** | 465.0 W | 433.0 W | 42.08 V | 35.02 V | 21.73% |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH (41.88 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.88V and beta_Voc=-0.266%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.89 V | 12 panels | 562.7 V | 21 panels |
| **-10 C (14 F)** | 45.78 V | 13 panels | 595.1 V | 21 panels |
| **0 C (32 F)** | 44.67 V | 13 panels | 580.7 V | 22 panels |
| **25 C (77 F STC)** | 41.88 V | 14 panels | 586.3 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-120-MF10-460W (460.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-MF10-460W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-460w/) Aptos Solar Technology LLC | 460.0 W | Tie (0 W) | 41.7 V | 21.3% | 93.8% |
| [**Elin Energy (Sirius PV) ELNSM60M-HC-460**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-460/) Elin Energy (Sirius PV) | 460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.3% |
| [**Elin Energy (Sirius PV) ELNSM60M-HC-LV-460**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-lv-460/) Elin Energy (Sirius PV) | 460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.3% |
| [**Aptos Solar Technology LLC DNA-120-BF10-460W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bf10-460w/) Aptos Solar Technology LLC | 460.0 W | Tie (0 W) | 41.5 V | 21.3% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH (460.0 W STC, 41.88 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH reaches 46.89 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF10-460W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 428.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH PTC wattage (428.2 W) lower than STC (460.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 428.2 W PTC (93.1% retention) across SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH's 2.14 m2 aperture.

### Who should skip SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH panels (415 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-120-MF10-460W.

### What is the 1,000 V commercial string limit for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH?

On 1,000 V commercial inverters at -10 C (45.78 V cold Voc), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH fits up to 21 panels per series string.

## Related Pages

Compare SOLAREVER TECNOLOG A DE AMERICA SA DE CV equipment, Aptos Solar Technology LLC DNA-120-MF10-460W specs, utility payback rates, and NEC string calculators alongside SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH.

[All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLAREVER TECNOLOG A DE AMERICA SA DE CV

- [All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Specs](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-555m-144/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-545m-144/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-455M-144N](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-166-83-455m-144n/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-450m-96-bd/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-445m-96-bd/)