title: "SOLAREVER TECNOLOG A DE AMERICA Specs (450.0W, 35.03V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-450m-96-bd/
description: "CEC datasheet for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD: 450.0W STC, 35.03V Voc, 18-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD — CEC Solar Module Specifications

Manufacturer: [**SOLAREVER TECNOLOG A DE AMERICA SA DE CV**](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) Registry: **CEC Verified Engineering Specification**

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD is a 450.0 W STC (423.6 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 22.73% efficiency, 35.03 V Voc at 25 C, and 38.1 V cold Voc at -10 C (15 panels max per 600 V string).

- **STC Wattage** : 450.0 W

- **PTC Wattage** : 423.6 W

- **Voc @ 25C** : 35.03 V

- **Efficiency** : 22.73%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD Compare Against Peer CEC Listings?

How SOLAREVER TECNOLOG A DE AMERICA SA DE CV SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD handles rooftop heat (423.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD exhibits 16.05 A short-circuit current, requiring a 25.04 A (156%) conductor rating and 30 A OCPD under NEC 690.8. Ranked #5,679 of 21,677 (40.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 35.6 m2 for an 8 kW system (23 panels for 10 kW). Lower 35.03 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

## Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD Fall Across Listed CEC Models?

Where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD (450.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD?

Percentile placement of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD across power density (227.3 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD specifications.

Rank #5,679 / 21,677

### Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,598

### 22.73% Aperture Efficiency

Power density 227.3 W/m2 (2.82 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

### 15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.1 V at -10 C (571.5 V string) and 38.97 V at -20 C (15 max).

 8 kW Reference Array

### 18 Panels = 8,100 W STC

Occupies 35.6 m2 (384 sq ft) producing 7,625 W PTC; NEC 690.8 OCPD floor is 25.04 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.03 * (1 + (-0.25/100) * (-10 - 25)) = 38.1 V | OCPD = 1.56 * 16.05 = 25.04 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD: Voc=35.03 V, beta_Voc=-0.25%/C, Isc=16.05 A, STC=450.0 W, Area=1.98 m2.

**Result:** 15 panels max on 600 V (571.5 V); 18 panels for 8 kW (384 sq ft).

## What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 423.6 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 35.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 16.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.08 V / 14.97 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.25 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.73% (1.98 m2) | Array roof footprint density |
| **Cell Count & Technology** | 32 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD (450.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.3 kW | 298 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 18 | 8.1 kW | 384 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 23 | 10.35 kW | 490 sq ft | $2,591 | $4,380 |

## How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=35.03V and beta_Voc=-0.25%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 38.97 V | 15 panels | 584.5 V | 25 panels |
| **-10 C (14 F)** | 38.1 V | 15 panels | 571.5 V | 26 panels |
| **0 C (32 F)** | 37.22 V | 16 panels | 595.5 V | 26 panels |
| **25 C (77 F STC)** | 35.03 V | 17 panels | 595.5 V | 28 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD?

Alternative CEC solar modules from competing brands near SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD (450.0 W), including Hanersun Energy Co Ltd HN21RN-48HT455W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanersun Energy Co Ltd HN21RN-48HT455W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn21rn-48ht455w/) Hanersun Energy Co Ltd | 455.0 W | +5.0 W | 35.93 V | 23.45% | 95.1% |
| [**CSI Solar Co Ltd CS62-48TM-455H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs62-48tm-455h/) CSI Solar Co Ltd | 455.0 W | +5.0 W | 36.0 V | 23.58% | 95.0% |
| [**G-Star Pte Ltd GSD8R48T-460BT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd8r48t-460bt/) G-Star Pte Ltd | 460.0 W | +10.0 W | 35.99 V | 23.23% | 95.2% |
| [**G-Star Pte Ltd GSD8R48T-460WT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd8r48t-460wt/) G-Star Pte Ltd | 460.0 W | +10.0 W | 35.99 V | 23.23% | 95.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD (450.0 W STC, 35.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD reaches 38.97 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 384 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (384 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD 8 kW Residential Fit

Needs 18 modules (384 sq ft) with a 30 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Hanersun Energy Co Ltd HN21RN-48HT455W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 423.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD PTC wattage (423.6 W) lower than STC (450.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 423.6 W PTC (94.1% retention) across SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD's 1.98 m2 aperture.

### Who should skip SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD panels (384 sq ft) leave unusable roof gaps vs. Hanersun Energy Co Ltd HN21RN-48HT455W.

### What is the 1,000 V commercial string limit for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD?

On 1,000 V commercial inverters at -10 C (38.1 V cold Voc), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD fits up to 26 panels per series string.

## Related Pages

Compare SOLAREVER TECNOLOG A DE AMERICA SA DE CV equipment, Hanersun Energy Co Ltd HN21RN-48HT455W specs, utility payback rates, and NEC string calculators alongside SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD.

[All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLAREVER TECNOLOG A DE AMERICA SA DE CV

- [All SOLAREVER TECNOLOG A DE AMERICA SA DE CV Specs](https://epri-peac.com/solar-equipment/brands/solarever-tecnolog-a-de-america-sa-de-cv/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-555m-144/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-545m-144/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-91-460m-120-bh/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-455M-144N](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-166-83-455m-144n/)
- [SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD](https://epri-peac.com/solar-equipment/modules/solarever-tecnolog-a-de-america-sa-de-cv/solarever-tecnolog-a-de-america-sa-de-cv-se-182-105-445m-96-bd/)