title: "SOLAR UTILITIES INC SH360M4H-UHB Specs (360.0W, 40.69V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solar-utilities-inc/solar-utilities-inc-sh360m4h-uhb/
description: "CEC datasheet for SOLAR UTILITIES INC SH360M4H-UHB: 360.0W STC, 40.69V Voc, 23-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# SOLAR UTILITIES INC SH360M4H-UHB — CEC Solar Module Specifications

Manufacturer: [**SOLAR UTILITIES INC**](https://epri-peac.com/solar-equipment/brands/solar-utilities-inc/) Registry: **CEC Verified Engineering Specification**

SOLAR UTILITIES INC SH360M4H-UHB is a 360.0 W STC (336.1 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.78% efficiency, 40.69 V Voc at 25 C, and 44.48 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 360.0 W

- **PTC Wattage** : 336.1 W

- **Voc @ 25C** : 40.69 V

- **Efficiency** : 19.78%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLAR UTILITIES INC SH360M4H-UHB Compare Against Peer CEC Listings?

Solar engineering breakdown for SOLAR UTILITIES INC SH360M4H-UHB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from SOLAR UTILITIES INC and peers, SOLAR UTILITIES INC SH360M4H-UHB stands 50.0 W below the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,532-$2,523/yr in baseline US bill offset. Mid-range 40.69 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

## Where Does SOLAR UTILITIES INC SH360M4H-UHB Fall Across Listed CEC Models?

Distribution marker showing SOLAR UTILITIES INC SH360M4H-UHB (360.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define SOLAR UTILITIES INC SH360M4H-UHB?

Dataset percentiles tracking SOLAR UTILITIES INC SH360M4H-UHB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for SOLAR UTILITIES INC SH360M4H-UHB?

Benchmark highlights for SOLAR UTILITIES INC SH360M4H-UHB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,385 / 21,677

### 360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,263

### 19.78% Aperture Efficiency

Power density 197.8 W/m2 (0.13 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.48 V at -10 C (578.2 V string) and 45.56 V at -20 C (13 max).

 8 kW Reference Array

### 23 Panels = 8,280 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,730 W PTC; NEC 690.8 OCPD floor is 17.39 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.69 * (1 + (-0.266/100) * (-10 - 25)) = 44.48 V | OCPD = 1.56 * 11.15 = 17.39 A

Inputs from CEC Modules.csv for SOLAR UTILITIES INC SH360M4H-UHB: Voc=40.69 V, beta_Voc=-0.266%/C, Isc=11.15 A, STC=360.0 W, Area=1.82 m2.

**Result:** 13 panels max on 600 V (578.2 V); 23 panels for 8 kW (451 sq ft).

## What Are the Published CEC Specifications for SOLAR UTILITIES INC SH360M4H-UHB?

Official CEC datasheet figures for SOLAR UTILITIES INC SH360M4H-UHB (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for SOLAR UTILITIES INC SH360M4H-UHB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 336.1 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.69 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.15 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.99 V / 10.68 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.266 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.78% (1.82 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLAR UTILITIES INC SH360M4H-UHB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SOLAR UTILITIES INC SH360M4H-UHB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.12 kW | 333 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 23 | 8.28 kW | 451 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 28 | 10.08 kW | 549 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This SOLAR UTILITIES INC Series?

Consolidated SOLAR UTILITIES INC wattage variants sharing the SOLAR UTILITIES INC SH360M4H-UHB mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the SOLAR UTILITIES INC SH360M4H-UHB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLAR UTILITIES INC SH355M4H-UHB** | 355.0 W | 331.4 W | 40.48 V | 33.71 V | 19.51% |
| **SOLAR UTILITIES INC SH360M4H-UHB** | 360.0 W | 336.1 W | 40.69 V | 32.99 V | 19.78% |
| **SOLAR UTILITIES INC SH365M4H-UHB** | 365.0 W | 340.9 W | 40.81 V | 33.96 V | 20.05% |

## How Many SOLAR UTILITIES INC SH360M4H-UHB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SOLAR UTILITIES INC SH360M4H-UHB (44.48 V at 14 F).

Computed from Voc=40.69V and beta_Voc=-0.266%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.56 V | 13 panels | 592.3 V | 21 panels |
| **-10 C (14 F)** | 44.48 V | 13 panels | 578.2 V | 22 panels |
| **0 C (32 F)** | 43.4 V | 13 panels | 564.2 V | 23 panels |
| **25 C (77 F STC)** | 40.69 V | 14 panels | 569.7 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLAR UTILITIES INC SH360M4H-UHB?

Competing CEC solar panels closest to SOLAR UTILITIES INC SH360M4H-UHB in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3L-360P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3L-360P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3l-360p/) CSI Solar Co Ltd | 360.0 W | Tie (0 W) | 40.6 V | 20.11% | 92.4% |
| [**Apollo Renewables Inc Apollo-M660BH-360BB**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m660bh-360bb/) Apollo Renewables Inc | 360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| [**AXITEC AC-360MH/120V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360mh-120v/) AXITEC | 360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
| [**AXITEC AC-360MH/120VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360mh-120vb/) AXITEC | 360.0 W | Tie (0 W) | 40.5 V | 19.89% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAR UTILITIES INC SH360M4H-UHB?

Evaluate SOLAR UTILITIES INC SH360M4H-UHB (360.0 W STC, 40.69 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLAR UTILITIES INC SH360M4H-UHB reaches 45.56 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (451 sq ft).
- 2026 tax credit baseline: cash residential installs of SOLAR UTILITIES INC SH360M4H-UHB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLAR UTILITIES INC SH360M4H-UHB 8 kW Residential Fit

Needs 23 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-360P.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 336.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAR UTILITIES INC SH360M4H-UHB by SOLAR UTILITIES INC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SOLAR UTILITIES INC SH360M4H-UHB?

Multiplying SOLAR UTILITIES INC SH360M4H-UHB's 11.15 A short-circuit current by 1.56 equals 17.39 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can SOLAR UTILITIES INC SH360M4H-UHB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.48 V cold Voc at 14 F and handles 11.15 A Isc; string inverters cap SOLAR UTILITIES INC SH360M4H-UHB at 13 panels on 600 V.

### Is SOLAR UTILITIES INC SH360M4H-UHB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAR UTILITIES INC SH360M4H-UHB rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

## Related Pages

Compare SOLAR UTILITIES INC equipment, CSI Solar Co Ltd CS3L-360P specs, utility payback rates, and NEC string calculators alongside SOLAR UTILITIES INC SH360M4H-UHB.

[All SOLAR UTILITIES INC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solar-utilities-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLAR UTILITIES INC

- [All SOLAR UTILITIES INC Specs](https://epri-peac.com/solar-equipment/brands/solar-utilities-inc/)
- [SOLAR UTILITIES INC SH360M4-UHB](https://epri-peac.com/solar-equipment/modules/solar-utilities-inc/solar-utilities-inc-sh360m4-uhb/)