title: "SOLAR LONG PV-TECH(CAMBODIA)COLTD Specs (555.0W, 50.62V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl555mlbt-72h-vtl/
description: "CEC datasheet for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL: 555.0W STC, 50.62V Voc, 15-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL — CEC Solar Module Specifications

Manufacturer: [**SOLAR LONG PV-TECH(CAMBODIA)COLTD**](https://epri-peac.com/solar-equipment/brands/solar-long-pv-tech-cambodia-coltd/) Registry: **CEC Verified Engineering Specification**

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL is a 555.0 W STC (517.4 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 22.2% efficiency, 50.62 V Voc at 25 C, and 55.78 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 555.0 W

- **PTC Wattage** : 517.4 W

- **Voc @ 25C** : 50.62 V

- **Efficiency** : 22.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL Compare Against Peer CEC Listings?

How SOLAR LONG PV-TECH(CAMBODIA)COLTD SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL handles rooftop heat (517.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL exhibits 13.65 A short-circuit current, requiring a 21.29 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,550 of 21,677 (145.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.5 m2 for an 8 kW system (19 panels for 10 kW). Higher 50.62 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL Fall Across Listed CEC Models?

Where SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL (555.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL?

Percentile placement of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL across power density (222.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL specifications.

Rank #2,550 / 21,677

### Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,649

### 22.2% Aperture Efficiency

Power density 222.0 W/m2 (2.29 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.78 V at -10 C (557.8 V string) and 57.25 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,325 W STC

Occupies 37.5 m2 (404 sq ft) producing 7,761 W PTC; NEC 690.8 OCPD floor is 21.29 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.62 * (1 + (-0.291/100) * (-10 - 25)) = 55.78 V | OCPD = 1.56 * 13.65 = 21.29 A

Inputs from CEC Modules.csv for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL: Voc=50.62 V, beta_Voc=-0.291%/C, Isc=13.65 A, STC=555.0 W, Area=2.5 m2.

**Result:** 10 panels max on 600 V (557.8 V); 15 panels for 8 kW (404 sq ft).

## What Are the Published CEC Specifications for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL.

Official California Energy Commission (NREL SAM) test parameters for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 517.4 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.62 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.71 V / 12.99 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.291 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.2% (2.5 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL (555.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.11 kW | 296 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 15 | 8.32 kW | 404 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 19 | 10.54 kW | 511 sq ft | $2,638 | $4,461 |

## Which Sibling Wattage & Trim Variants Belong to This SOLAR LONG PV-TECH(CAMBODIA)COLTD Series?

All closely matched SOLAR LONG PV-TECH(CAMBODIA)COLTD wattages and cosmetic trims sharing the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL architecture.

Sibling CEC listings grouped into the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLAR LONG PV-TECH(CAMBODIA)COLTD SL550MLBT-72H-VTL** | 550.0 W | 512.6 W | 50.32 V | 42.49 V | 22.0% |
| **SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL** | 555.0 W | 517.4 W | 50.62 V | 42.71 V | 22.2% |

## How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.62V and beta_Voc=-0.291%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 57.25 V | 10 panels | 572.5 V | 17 panels |
| **-10 C (14 F)** | 55.78 V | 10 panels | 557.8 V | 17 panels |
| **0 C (32 F)** | 54.3 V | 11 panels | 597.3 V | 18 panels |
| **25 C (77 F STC)** | 50.62 V | 11 panels | 556.8 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL?

Alternative CEC solar modules from competing brands near SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL (555.0 W), including Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-555/) Chint New Energy Technology Co Ltd | 555.0 W | Tie (0 W) | 50.5 V | 22.38% | 92.9% |
| [**ASTORIOS Holding Inc ASTR144BDG-555W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr144bdg-555w-us/) ASTORIOS Holding Inc | 555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.7% |
| [**AXITEC AC-555MBT/144US**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144us/) AXITEC | 555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.6% |
| [**Energy America LLC EA-ZLK7-SHDB144-555/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb144-555-m/) Energy America LLC | 555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL?

Evaluate SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL (555.0 W STC, 50.62 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL reaches 57.25 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL 8 kW Residential Fit

Needs 15 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 517.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL by SOLAR LONG PV-TECH(CAMBODIA)COLTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL PTC wattage (517.4 W) lower than STC (555.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 517.4 W PTC (93.2% retention) across SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL's 2.5 m2 aperture.

### Who should skip SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL panels (404 sq ft) leave unusable roof gaps vs. Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555.

### What is the 1,000 V commercial string limit for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL?

On 1,000 V commercial inverters at -10 C (55.78 V cold Voc), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL fits up to 17 panels per series string.

## Related Pages

Compare SOLAR LONG PV-TECH(CAMBODIA)COLTD equipment, Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555 specs, utility payback rates, and NEC string calculators alongside SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL.

[All SOLAR LONG PV-TECH(CAMBODIA)COLTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solar-long-pv-tech-cambodia-coltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLAR LONG PV-TECH(CAMBODIA)COLTD

- [All SOLAR LONG PV-TECH(CAMBODIA)COLTD Specs](https://epri-peac.com/solar-equipment/brands/solar-long-pv-tech-cambodia-coltd/)
- [SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl540mlbt-72h-vtl/)
- [SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl410ml-54h-vtl/)
- [SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl395ml-54h-vtl/)