title: "SOLAR LONG PV-TECH(CAMBODIA)COLTD Specs (395.0W, 36.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl395ml-54h-vtl/
description: "CEC datasheet for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL: 395.0W STC, 36.9V Voc, 21-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL — CEC Solar Module Specifications

Manufacturer: [**SOLAR LONG PV-TECH(CAMBODIA)COLTD**](https://epri-peac.com/solar-equipment/brands/solar-long-pv-tech-cambodia-coltd/) Registry: **CEC Verified Engineering Specification**

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL is a 395.0 W STC (369.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 36.9 V Voc at 25 C, and 40.41 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 369.0 W

- **Voc @ 25C** : 36.9 V

- **Efficiency** : 20.36%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Compare Against Peer CEC Listings?

How SOLAR LONG PV-TECH(CAMBODIA)COLTD SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL handles rooftop heat (369.0 W PTC), 8 kW sizing, and cold winter string voltage.

SOLAR LONG PV-TECH(CAMBODIA)COLTD builds the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). Compared against BYD Company Limited BYD395MLK-27 (395.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Lower 36.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.39 A overcurrent floor served by a 25 A breaker.

## Where Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Fall Across Listed CEC Models?

Where SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Percentile placement of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL across power density (203.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL specifications.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,064

### 20.36% Aperture Efficiency

Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.41 V at -10 C (565.7 V string) and 41.42 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 40.7 m2 (439 sq ft) producing 7,749 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.9 * (1 + (-0.272/100) * (-10 - 25)) = 40.41 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL: Voc=36.9 V, beta_Voc=-0.272%/C, Isc=13.71 A, STC=395.0 W, Area=1.94 m2.

**Result:** 14 panels max on 600 V (565.7 V); 21 panels for 8 kW (439 sq ft).

## What Are the Published CEC Specifications for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL.

Official California Energy Commission (NREL SAM) test parameters for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 369.0 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.32 V / 13.03 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.272 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.36% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 334 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 439 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 543 sq ft | $2,570 | $4,347 |

## How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.9V and beta_Voc=-0.272%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.42 V | 14 panels | 579.9 V | 24 panels |
| **-10 C (14 F)** | 40.41 V | 14 panels | 565.7 V | 24 panels |
| **0 C (32 F)** | 39.41 V | 15 panels | 591.1 V | 25 panels |
| **25 C (77 F STC)** | 36.9 V | 16 panels | 590.4 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Alternative CEC solar modules from competing brands near SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W), including BYD Company Limited BYD395MLK-27.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**BYD Company Limited BYD395MLK-27**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd395mlk-27/) BYD Company Limited | 395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.6% |
| [**Energate Energy Inc EG-108L395W**](https://epri-peac.com/solar-equipment/modules/energate-energy-inc/energate-energy-inc-eg-108l395w/) Energate Energy Inc | 395.0 W | Tie (0 W) | 36.9 V | 20.36% | 93.6% |
| [**Energate Enerji retim San A EG-108L395W**](https://epri-peac.com/solar-equipment/modules/energate-enerji-retim-san-a/energate-enerji-retim-san-a-eg-108l395w/) Energate Enerji retim San A | 395.0 W | Tie (0 W) | 36.9 V | 20.36% | 93.6% |
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae395md-108/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 395.0 W | Tie (0 W) | 36.94 V | 20.47% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Evaluate SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W STC, 36.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL reaches 41.42 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL 8 kW Residential Fit

Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD395MLK-27.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL by SOLAR LONG PV-TECH(CAMBODIA)COLTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Multiplying SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.41 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL at 14 panels on 600 V.

### Is SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

## Related Pages

Compare SOLAR LONG PV-TECH(CAMBODIA)COLTD equipment, BYD Company Limited BYD395MLK-27 specs, utility payback rates, and NEC string calculators alongside SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL.

[All SOLAR LONG PV-TECH(CAMBODIA)COLTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solar-long-pv-tech-cambodia-coltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLAR LONG PV-TECH(CAMBODIA)COLTD

- [All SOLAR LONG PV-TECH(CAMBODIA)COLTD Specs](https://epri-peac.com/solar-equipment/brands/solar-long-pv-tech-cambodia-coltd/)
- [SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl555mlbt-72h-vtl/)
- [SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl540mlbt-72h-vtl/)
- [SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL](https://epri-peac.com/solar-equipment/modules/solar-long-pv-tech-cambodia-coltd/solar-long-pv-tech-cambodia-coltd-sl410ml-54h-vtl/)