title: "Solar Frontier KK SF160-S Specs (160.0W, 110.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solar-frontier-kk/solar-frontier-kk-sf160-s/
description: "CEC datasheet for Solar Frontier KK SF160-S: 160.0W STC, 110.0V Voc, 50-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Solar Frontier KK SF160-S — CEC Solar Module Specifications

Manufacturer: [**Solar Frontier KK**](https://epri-peac.com/solar-equipment/brands/solar-frontier-kk/) Registry: **CEC Verified Engineering Specification**

Solar Frontier KK SF160-S is a 160.0 W STC (144.6 W PTC) Thin Film solar module ranking #21,373 of 21,677 CEC listings (below all-CEC median; higher than 1.3% of peers). It delivers 15.28% efficiency, 110.0 V Voc at 25 C, and 121.55 V cold Voc at -10 C (4 panels max per 600 V string).

- **STC Wattage** : 160.0 W

- **PTC Wattage** : 144.6 W

- **Voc @ 25C** : 110.0 V

- **Efficiency** : 15.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Solar Frontier KK SF160-S Compare Against Peer CEC Listings?

Solar engineering breakdown for Solar Frontier KK SF160-S: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 106 Thin Film listings from Solar Frontier KK and peers, Solar Frontier KK SF160-S stands 42.5 W above the 117.5 W Thin Film median and typical 90.4% PTC-to-STC thermal output (144.6 W real-world rating). Sizing 6 kW (38 panels) to 10 kW (63 panels) yields $1,522-$2,523/yr in baseline US bill offset. Higher 110.0 V open-circuit voltage caps 600 V residential strings at 4 panels at 14 F (-10 C).

## Where Does Solar Frontier KK SF160-S Fall Across Listed CEC Models?

Distribution marker showing Solar Frontier KK SF160-S (160.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Solar Frontier KK SF160-S?

Dataset percentiles tracking Solar Frontier KK SF160-S power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Solar Frontier KK SF160-S?

Benchmark highlights for Solar Frontier KK SF160-S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,373 / 21,677

### 160.0 W STC · Higher Than 1.3%

160.0 W STC (-225.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #19,278

### 15.28% Aperture Efficiency

Power density 152.8 W/m2 (4.63 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

### 4 Panels Max @ -10 C (600 V)

Cold Voc reaches 121.55 V at -10 C (486.2 V string) and 124.85 V at -20 C (4 max).

 8 kW Reference Array

### 50 Panels = 8,000 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,230 W PTC; NEC 690.8 OCPD floor is 3.43 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 110.0 * (1 + (-0.3/100) * (-10 - 25)) = 121.55 V | OCPD = 1.56 * 2.2 = 3.43 A

Inputs from CEC Modules.csv for Solar Frontier KK SF160-S: Voc=110.0 V, beta_Voc=-0.3%/C, Isc=2.2 A, STC=160.0 W, Area=1.047 m2.

**Result:** 4 panels max on 600 V (486.2 V); 50 panels for 8 kW (563 sq ft).

## What Are the Published CEC Specifications for Solar Frontier KK SF160-S?

Official CEC datasheet figures for Solar Frontier KK SF160-S (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Solar Frontier KK SF160-S.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 160.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 144.6 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 110.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 2.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 84.0 V / 1.91 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.3 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.28% (1.047 m2) | Array roof footprint density |
| **Cell Count & Technology** | 170 cells (Thin Film) | Monofacial backsheet |

## How Many Solar Frontier KK SF160-S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solar Frontier KK SF160-S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 38 | 6.08 kW | 428 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 50 | 8.0 kW | 563 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 63 | 10.08 kW | 710 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Solar Frontier KK Series?

Consolidated Solar Frontier KK wattage variants sharing the Solar Frontier KK SF160-S mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Solar Frontier KK SF160-S wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Solar Frontier KK SF150-S** | 150.0 W | 135.8 W | 108.0 V | 81.5 V | 14.33% |
| **Solar Frontier KK SF155-S** | 155.0 W | 140.5 W | 109.0 V | 82.5 V | 14.81% |
| **Solar Frontier KK SF160-S** | 160.0 W | 144.6 W | 110.0 V | 84.0 V | 15.28% |
| **Solar Frontier KK SF165-S** | 165.0 W | 149.2 W | 110.0 V | 85.5 V | 15.76% |
| **Solar Frontier KK SF170-S** | 170.0 W | 153.8 W | 112.0 V | 87.5 V | 16.24% |

## How Many Solar Frontier KK SF160-S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solar Frontier KK SF160-S (121.55 V at 14 F).

Computed from Voc=110.0V and beta_Voc=-0.3%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 124.85 V | 4 panels | 499.4 V | 8 panels |
| **-10 C (14 F)** | 121.55 V | 4 panels | 486.2 V | 8 panels |
| **0 C (32 F)** | 118.25 V | 5 panels | 591.2 V | 8 panels |
| **25 C (77 F STC)** | 110.0 V | 5 panels | 550.0 V | 9 panels |

## Which Cross-Brand Solar Modules Compare Closest to Solar Frontier KK SF160-S?

Competing CEC solar panels closest to Solar Frontier KK SF160-S in nameplate wattage and Voc, starting with Du Pont Apollo DA105-A2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Du Pont Apollo DA105-A2**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da105-a2/) Du Pont Apollo | 105.0 W | -55.0 W | 100.0 V | 6.82% | 91.0% |
| [**Du Pont Apollo DA102-A6**](https://epri-peac.com/solar-equipment/modules/du-pont-apollo/du-pont-apollo-da102-a6/) Du Pont Apollo | 102.0 W | -58.0 W | 100.0 V | 6.62% | 94.2% |
| [**Applied Materials 1/4 Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-1-4-size-single-junction-version-10/) Applied Materials | 116.0 W | -44.0 W | 96.2 V | 8.11% | 93.0% |
| [**Centrosolar America VS-155C2**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-vs-155c2/) Centrosolar America | 155.0 W | -5.0 W | 82.85 V | 14.27% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Solar Frontier KK SF160-S?

Evaluate Solar Frontier KK SF160-S (160.0 W STC, 110.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Solar Frontier KK SF160-S reaches 124.85 V per panel—exceeding 4 panels in series voids 600 V inverter warranties.
- Footprint constraint: 50 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 50 panels (563 sq ft).
- 2026 tax credit baseline: cash residential installs of Solar Frontier KK SF160-S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Solar Frontier KK SF160-S 8 kW Residential Fit

Needs 50 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 4 panels (-10 C) or 4 panels (-20 C), or compare Du Pont Apollo DA105-A2.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 144.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solar Frontier KK SF160-S by Solar Frontier KK grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Solar Frontier KK SF160-S?

Multiplying Solar Frontier KK SF160-S's 2.2 A short-circuit current by 1.56 equals 3.43 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Solar Frontier KK SF160-S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 121.55 V cold Voc at 14 F and handles 2.2 A Isc; string inverters cap Solar Frontier KK SF160-S at 4 panels on 600 V.

### Is Solar Frontier KK SF160-S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solar Frontier KK SF160-S rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

## Related Pages

Compare Solar Frontier KK equipment, Du Pont Apollo DA105-A2 specs, utility payback rates, and NEC string calculators alongside Solar Frontier KK SF160-S.

[All Solar Frontier KK Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solar-frontier-kk/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Solar Frontier KK

- [All Solar Frontier KK Specs](https://epri-peac.com/solar-equipment/brands/solar-frontier-kk/)
- [Solar Frontier KK SFK185-S](https://epri-peac.com/solar-equipment/modules/solar-frontier-kk/solar-frontier-kk-sfk185-s/)
- [Solar Frontier KK SF175-S](https://epri-peac.com/solar-equipment/modules/solar-frontier-kk/solar-frontier-kk-sf175-s/)
- [Solar Frontier KK SF160-S-1500](https://epri-peac.com/solar-equipment/modules/solar-frontier-kk/solar-frontier-kk-sf160-s-1500/)
- [Solar Frontier KK SF140-S](https://epri-peac.com/solar-equipment/modules/solar-frontier-kk/solar-frontier-kk-sf140-s/)
- [Solar Frontier KK SF140-S-1500](https://epri-peac.com/solar-equipment/modules/solar-frontier-kk/solar-frontier-kk-sf140-s-1500/)