title: "Silfab Solar Inc SLA300M Specs (300.0W, 39.85V Voc)"
url: https://epri-peac.com/solar-equipment/modules/silfab-solar-inc/silfab-solar-inc-sla300m/
description: "CEC datasheet for Silfab Solar Inc SLA300M: 300.0W STC, 39.85V Voc, 27-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Silfab Solar Inc SLA300M — CEC Solar Module Specifications

Manufacturer: [**Silfab Solar Inc**](https://epri-peac.com/solar-equipment/brands/silfab-solar-inc/) Registry: **CEC Verified Engineering Specification**

Silfab Solar Inc SLA300M is a 300.0 W STC (272.0 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 19.11% efficiency, 39.85 V Voc at 25 C, and 43.74 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 272.0 W

- **Voc @ 25C** : 39.85 V

- **Efficiency** : 19.11%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Silfab Solar Inc SLA300M Compare Against Peer CEC Listings?

Solar engineering breakdown for Silfab Solar Inc SLA300M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 300.0 W STC and 272.0 W PTC, Silfab Solar Inc SLA300M sits -85.0 W vs all-CEC median (below all-CEC median; higher than 22.1% of peers) among 21,677 listed modules. Power density reaches 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). Lower 39.85 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Enphase Energy Inc XACM-IQ7-LR6-60PB-300M rates 300.0 W.

## Where Does Silfab Solar Inc SLA300M Fall Across Listed CEC Models?

Distribution marker showing Silfab Solar Inc SLA300M (300.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Silfab Solar Inc SLA300M?

Dataset percentiles tracking Silfab Solar Inc SLA300M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Silfab Solar Inc SLA300M?

Benchmark highlights for Silfab Solar Inc SLA300M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,188

### 19.11% Aperture Efficiency

Power density 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.74 V at -10 C (568.6 V string) and 44.85 V at -20 C (13 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 42.4 m2 (456 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 15.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.85 * (1 + (-0.279/100) * (-10 - 25)) = 43.74 V | OCPD = 1.56 * 9.71 = 15.15 A

Inputs from CEC Modules.csv for Silfab Solar Inc SLA300M: Voc=39.85 V, beta_Voc=-0.279%/C, Isc=9.71 A, STC=300.0 W, Area=1.57 m2.

**Result:** 13 panels max on 600 V (568.6 V); 27 panels for 8 kW (456 sq ft).

## What Are the Published CEC Specifications for Silfab Solar Inc SLA300M?

Official CEC datasheet figures for Silfab Solar Inc SLA300M (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Silfab Solar Inc SLA300M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 272.0 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.8 V / 9.16 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.279 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.11% (1.57 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Silfab Solar Inc SLA300M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Silfab Solar Inc SLA300M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 338 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 456 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 575 sq ft | $2,553 | $4,317 |

## How Many Silfab Solar Inc SLA300M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Silfab Solar Inc SLA300M (43.74 V at 14 F).

Computed from Voc=39.85V and beta_Voc=-0.279%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.85 V | 13 panels | 583.1 V | 22 panels |
| **-10 C (14 F)** | 43.74 V | 13 panels | 568.6 V | 22 panels |
| **0 C (32 F)** | 42.63 V | 14 panels | 596.8 V | 23 panels |
| **25 C (77 F STC)** | 39.85 V | 15 panels | 597.8 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Silfab Solar Inc SLA300M?

Competing CEC solar panels closest to Silfab Solar Inc SLA300M in nameplate wattage and Voc, starting with Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Enphase Energy Inc XACM-IQ7-LR6-60PB-300M**](https://epri-peac.com/solar-equipment/modules/enphase-energy-inc/enphase-energy-inc-xacm-iq7-lr6-60pb-300m/) Enphase Energy Inc | 300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
| [**FreeVolt PV-GRAF-60M6-300/M**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-pv-graf-60m6-300-m/) FreeVolt | 300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| [**CertainTeed CT300M10-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m10-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.55% | 92.4% |
| [**CertainTeed CT300M11-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m11-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.68% | 92.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Silfab Solar Inc SLA300M?

Evaluate Silfab Solar Inc SLA300M (300.0 W STC, 39.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Silfab Solar Inc SLA300M reaches 44.85 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 456 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (456 sq ft).
- 2026 tax credit baseline: cash residential installs of Silfab Solar Inc SLA300M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Silfab Solar Inc SLA300M 8 kW Residential Fit

Needs 27 modules (456 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 272.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Silfab Solar Inc SLA300M by Silfab Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Silfab Solar Inc SLA300M panels fit on a 600 V winter solar string?

At -10 C (14 F), Silfab Solar Inc SLA300M cold Voc rises from 39.85 V to 43.74 V (beta_Voc -0.279%/C), capping a 600 V string at 13 panels (568.6 V).

### How much roof area does an 8 kW array of Silfab Solar Inc SLA300M need?

An 8 kW DC system uses 27 Silfab Solar Inc SLA300M modules (8,100 W STC / 7,344 W PTC), covering roughly 456 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does Silfab Solar Inc SLA300M compare against Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?

Silfab Solar Inc SLA300M outputs 300.0 W STC (39.85 V Voc, rank #16,498 of 21,677), while Enphase Energy Inc XACM-IQ7-LR6-60PB-300M delivers 300.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Silfab Solar Inc equipment, Enphase Energy Inc XACM-IQ7-LR6-60PB-300M specs, utility payback rates, and NEC string calculators alongside Silfab Solar Inc SLA300M.

[All Silfab Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/silfab-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Silfab Solar Inc

- [All Silfab Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/silfab-solar-inc/)
- [Silfab Solar Inc SIL-640XL](https://epri-peac.com/solar-equipment/modules/silfab-solar-inc/silfab-solar-inc-sil-640xl/)
- [Silfab Solar Inc SIL-620XL](https://epri-peac.com/solar-equipment/modules/silfab-solar-inc/silfab-solar-inc-sil-620xl/)
- [Silfab Solar Inc SIL-580XM+](https://epri-peac.com/solar-equipment/modules/silfab-solar-inc/silfab-solar-inc-sil-580xm/)
- [Silfab Solar Inc SIL-565XM+](https://epri-peac.com/solar-equipment/modules/silfab-solar-inc/silfab-solar-inc-sil-565xm/)
- [Silfab Solar Inc SIL-535QM](https://epri-peac.com/solar-equipment/modules/silfab-solar-inc/silfab-solar-inc-sil-535qm/)