title: "Shanghai ST Solar STM350-130 Specs (350.0W, 81.25V Voc)"
url: https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm350-130/
description: "CEC datasheet for Shanghai ST Solar STM350-130: 350.0W STC, 81.25V Voc, 23-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Shanghai ST Solar STM350-130 — CEC Solar Module Specifications

Manufacturer: [**Shanghai ST Solar**](https://epri-peac.com/solar-equipment/brands/shanghai-st-solar/) Registry: **CEC Verified Engineering Specification**

Shanghai ST Solar STM350-130 is a 350.0 W STC (312.9 W PTC) Mono-c-Si solar module ranking #13,031 of 21,677 CEC listings (below all-CEC median; higher than 38.6% of peers). It delivers 15.43% efficiency, 81.25 V Voc at 25 C, and 90.92 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 350.0 W

- **PTC Wattage** : 312.9 W

- **Voc @ 25C** : 81.25 V

- **Efficiency** : 15.43%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Shanghai ST Solar STM350-130 Compare Against Peer CEC Listings?

Solar engineering breakdown for Shanghai ST Solar STM350-130: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Shanghai ST Solar and peers, Shanghai ST Solar STM350-130 stands 60.0 W below the 410.0 W Mono-c-Si median and typical 89.4% PTC-to-STC thermal output (312.9 W real-world rating). Sizing 6 kW (18 panels) to 10 kW (29 panels) yields $1,577-$2,540/yr in baseline US bill offset. Higher 81.25 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).

## Where Does Shanghai ST Solar STM350-130 Fall Across Listed CEC Models?

Distribution marker showing Shanghai ST Solar STM350-130 (350.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Shanghai ST Solar STM350-130?

Dataset percentiles tracking Shanghai ST Solar STM350-130 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Shanghai ST Solar STM350-130?

Benchmark highlights for Shanghai ST Solar STM350-130 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #13,031 / 21,677

### 350.0 W STC · Higher Than 38.6%

350.0 W STC (-35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,102

### 15.43% Aperture Efficiency

Power density 154.3 W/m2 (4.48 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 90.92 V at -10 C (545.5 V string) and 93.68 V at -20 C (6 max).

 8 kW Reference Array

### 23 Panels = 8,050 W STC

Occupies 52.2 m2 (562 sq ft) producing 7,197 W PTC; NEC 690.8 OCPD floor is 9.33 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 81.25 * (1 + (-0.34/100) * (-10 - 25)) = 90.92 V | OCPD = 1.56 * 5.98 = 9.33 A

Inputs from CEC Modules.csv for Shanghai ST Solar STM350-130: Voc=81.25 V, beta_Voc=-0.34%/C, Isc=5.98 A, STC=350.0 W, Area=2.269 m2.

**Result:** 6 panels max on 600 V (545.5 V); 23 panels for 8 kW (562 sq ft).

## What Are the Published CEC Specifications for Shanghai ST Solar STM350-130?

Official CEC datasheet figures for Shanghai ST Solar STM350-130 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STM350-130.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 350.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 312.9 W (89.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 81.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 5.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 65.0 V / 5.38 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.43% (2.269 m2) | Array roof footprint density |
| **Cell Count & Technology** | 130 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Shanghai ST Solar STM350-130 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Shanghai ST Solar STM350-130 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 18 | 6.3 kW | 440 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 23 | 8.05 kW | 562 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 29 | 10.15 kW | 708 sq ft | $2,540 | $4,296 |

## How Many Shanghai ST Solar STM350-130 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Shanghai ST Solar STM350-130 (90.92 V at 14 F).

Computed from Voc=81.25V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 93.68 V | 6 panels | 562.1 V | 10 panels |
| **-10 C (14 F)** | 90.92 V | 6 panels | 545.5 V | 10 panels |
| **0 C (32 F)** | 88.16 V | 6 panels | 529.0 V | 11 panels |
| **25 C (77 F STC)** | 81.25 V | 7 panels | 568.8 V | 12 panels |

## Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM350-130?

Competing CEC solar panels closest to Shanghai ST Solar STM350-130 in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-350w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 350.0 W | Tie (0 W) | 47.64 V | 18.2% | 91.5% |
| [**Centrosolar America EM72 350BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350bw/) Centrosolar America | 350.0 W | Tie (0 W) | 47.64 V | 18.2% | 91.5% |
| [**Centrosolar America EM72 350SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350sw/) Centrosolar America | 350.0 W | Tie (0 W) | 47.64 V | 18.2% | 91.5% |
| [**CSI Solar Co Ltd CS3U-350P-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-350p-ag/) CSI Solar Co Ltd | 350.0 W | Tie (0 W) | 46.6 V | 18.23% | 92.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM350-130?

Evaluate Shanghai ST Solar STM350-130 (350.0 W STC, 81.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM350-130 reaches 93.68 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 562 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (562 sq ft).
- 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM350-130 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Shanghai ST Solar STM350-130 8 kW Residential Fit

Needs 23 modules (562 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 312.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STM350-130 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Shanghai ST Solar STM350-130?

Multiplying Shanghai ST Solar STM350-130's 5.98 A short-circuit current by 1.56 equals 9.33 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Shanghai ST Solar STM350-130 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 90.92 V cold Voc at 14 F and handles 5.98 A Isc; string inverters cap Shanghai ST Solar STM350-130 at 6 panels on 600 V.

### Is Shanghai ST Solar STM350-130 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Shanghai ST Solar STM350-130 rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

## Related Pages

Compare Shanghai ST Solar equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W specs, utility payback rates, and NEC string calculators alongside Shanghai ST Solar STM350-130.

[All Shanghai ST Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/shanghai-st-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Shanghai ST Solar

- [All Shanghai ST Solar Specs](https://epri-peac.com/solar-equipment/brands/shanghai-st-solar/)
- [Shanghai ST Solar STM335-130](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm335-130/)
- [Shanghai ST Solar STP300-72](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stp300-72/)
- [Shanghai ST Solar STP285-72](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stp285-72/)
- [Shanghai ST Solar STM280-104](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm280-104/)
- [Shanghai ST Solar STM265-104](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm265-104/)