title: "Shanghai ST Solar STM200-72 Specs (200.0W, 45.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm200-72/
description: "CEC datasheet for Shanghai ST Solar STM200-72: 200.0W STC, 45.0V Voc, 40-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Shanghai ST Solar STM200-72 — CEC Solar Module Specifications

Manufacturer: [**Shanghai ST Solar**](https://epri-peac.com/solar-equipment/brands/shanghai-st-solar/) Registry: **CEC Verified Engineering Specification**

Shanghai ST Solar STM200-72 is a 200.0 W STC (178.9 W PTC) Mono-c-Si solar module ranking #21,027 of 21,677 CEC listings (below all-CEC median; higher than 2.7% of peers). It delivers 15.67% efficiency, 45.0 V Voc at 25 C, and 50.35 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 200.0 W

- **PTC Wattage** : 178.9 W

- **Voc @ 25C** : 45.0 V

- **Efficiency** : 15.67%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Shanghai ST Solar STM200-72 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai ST Solar STM200-72 (Mono-c-Si) residential solar systems.

Shanghai ST Solar STM200-72 delivers 156.6 W/m2 (4.24 percentage points below 19.91% CEC median) and typical 89.5% PTC-to-STC thermal output (178.9 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (550 sq ft). At -4 F (-20 C), string voltage climbs to 51.88 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Anhui Rinengzhongtian Semiconductor Development QJM200-72 (200.0 W).

## Where Does Shanghai ST Solar STM200-72 Fall Across Listed CEC Models?

Comparison of Shanghai ST Solar STM200-72 (200.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Shanghai ST Solar STM200-72?

Relative ranking of Shanghai ST Solar STM200-72 across nameplate watts, 89.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Shanghai ST Solar STM200-72?

Summary of Shanghai ST Solar STM200-72 output rank, 8 kW array size (40 panels), efficiency rating, and 600 V string limit.

Rank #21,027 / 21,677

### 200.0 W STC · Higher Than 2.7%

200.0 W STC (-185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,676

### 15.67% Aperture Efficiency

Power density 156.6 W/m2 (4.24 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.35 V at -10 C (553.9 V string) and 51.88 V at -20 C (11 max).

 8 kW Reference Array

### 40 Panels = 8,000 W STC

Occupies 51.1 m2 (550 sq ft) producing 7,156 W PTC; NEC 690.8 OCPD floor is 9.64 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.0 * (1 + (-0.34/100) * (-10 - 25)) = 50.35 V | OCPD = 1.56 * 6.18 = 9.64 A

Inputs from CEC Modules.csv for Shanghai ST Solar STM200-72: Voc=45.0 V, beta_Voc=-0.34%/C, Isc=6.18 A, STC=200.0 W, Area=1.277 m2.

**Result:** 11 panels max on 600 V (553.9 V); 40 panels for 8 kW (550 sq ft).

## What Are the Published CEC Specifications for Shanghai ST Solar STM200-72?

Complete CEC test sheet for Shanghai ST Solar STM200-72 including Isc (6.18 A), Voc (45.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STM200-72.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 200.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 178.9 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 6.18 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.0 V / 5.56 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.67% (1.277 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Shanghai ST Solar STM200-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai ST Solar STM200-72.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 30 | 6.0 kW | 412 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 40 | 8.0 kW | 550 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 50 | 10.0 kW | 687 sq ft | $2,503 | $4,232 |

## How Many Shanghai ST Solar STM200-72 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Shanghai ST Solar STM200-72 (45.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.0V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.88 V | 11 panels | 570.7 V | 19 panels |
| **-10 C (14 F)** | 50.35 V | 11 panels | 553.9 V | 19 panels |
| **0 C (32 F)** | 48.82 V | 12 panels | 585.8 V | 20 panels |
| **25 C (77 F STC)** | 45.0 V | 13 panels | 585.0 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM200-72?

Four comparable CEC modules such as Anhui Rinengzhongtian Semiconductor Development QJM200-72 (200.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJM200-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm200-72/) Anhui Rinengzhongtian Semiconductor Development | 200.0 W | Tie (0 W) | 45.7 V | 15.67% | 89.0% |
| [**AXITEC AC-200M/125-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-200m-125-72s/) AXITEC | 200.0 W | Tie (0 W) | 45.87 V | 15.67% | 89.9% |
| [**Eoplly New Energy Technology EP125M/72-205W**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep125m-72-205w/) Eoplly New Energy Technology | 205.0 W | +5.0 W | 46.21 V | 16.06% | 89.0% |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) CSI Solar Co Ltd | 200.0 W | Tie (0 W) | 36.2 V | 12.43% | 91.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM200-72?

Evaluate Shanghai ST Solar STM200-72 (200.0 W STC, 45.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM200-72 reaches 51.88 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 40 panels for an 8 kW build require 550 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (550 sq ft).
- 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM200-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Shanghai ST Solar STM200-72 8 kW Residential Fit

Needs 40 modules (550 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM200-72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 178.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STM200-72 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Shanghai ST Solar STM200-72 panels fit on a 600 V winter solar string?

At -10 C (14 F), Shanghai ST Solar STM200-72 cold Voc rises from 45.0 V to 50.35 V (beta_Voc -0.34%/C), capping a 600 V string at 11 panels (553.9 V).

### How much roof area does an 8 kW array of Shanghai ST Solar STM200-72 need?

An 8 kW DC system uses 40 Shanghai ST Solar STM200-72 modules (8,000 W STC / 7,156 W PTC), covering roughly 550 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does Shanghai ST Solar STM200-72 compare against Anhui Rinengzhongtian Semiconductor Development QJM200-72?

Shanghai ST Solar STM200-72 outputs 200.0 W STC (45.0 V Voc, rank #21,027 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJM200-72 delivers 200.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Shanghai ST Solar equipment, Anhui Rinengzhongtian Semiconductor Development QJM200-72 specs, utility payback rates, and NEC string calculators alongside Shanghai ST Solar STM200-72.

[All Shanghai ST Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/shanghai-st-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Shanghai ST Solar

- [All Shanghai ST Solar Specs](https://epri-peac.com/solar-equipment/brands/shanghai-st-solar/)
- [Shanghai ST Solar STM350-130](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm350-130/)
- [Shanghai ST Solar STM335-130](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm335-130/)
- [Shanghai ST Solar STP300-72](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stp300-72/)
- [Shanghai ST Solar STP285-72](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stp285-72/)
- [Shanghai ST Solar STM280-104](https://epri-peac.com/solar-equipment/modules/shanghai-st-solar/shanghai-st-solar-stm280-104/)