title: "SEG Solar Inc SEG-605-BTA-BG Specs (605.0W, 53.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-605-bta-bg/
description: "CEC datasheet for SEG Solar Inc SEG-605-BTA-BG: 605.0W STC, 53.0V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# SEG Solar Inc SEG-605-BTA-BG — CEC Solar Module Specifications

Manufacturer: [**SEG Solar Inc**](https://epri-peac.com/solar-equipment/brands/seg-solar-inc/) Registry: **CEC Verified Engineering Specification**

SEG Solar Inc SEG-605-BTA-BG is a 605.0 W STC (579.1 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 24.1% efficiency, 53.0 V Voc at 25 C, and 57.3 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 605.0 W

- **PTC Wattage** : 579.1 W

- **Voc @ 25C** : 53.0 V

- **Efficiency** : 24.1%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SEG Solar Inc SEG-605-BTA-BG Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SEG Solar Inc SEG-605-BTA-BG (Mono-c-Si) residential solar systems.

Homeowners evaluating SEG Solar Inc SEG-605-BTA-BG need 10 panels for 6 kW or 14 panels (378 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.232%/C) pushes open-circuit voltage to 57.3 V at 14 F and 58.53 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does SEG Solar Inc SEG-605-BTA-BG Fall Across Listed CEC Models?

Comparison of SEG Solar Inc SEG-605-BTA-BG (605.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define SEG Solar Inc SEG-605-BTA-BG?

Relative ranking of SEG Solar Inc SEG-605-BTA-BG across nameplate watts, 95.7% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for SEG Solar Inc SEG-605-BTA-BG?

Summary of SEG Solar Inc SEG-605-BTA-BG output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,214 / 21,677

### Top 6.1% STC Output

605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #187

### 24.1% Aperture Efficiency

Power density 241.0 W/m2 (4.19 percentage points above 19.91% CEC median). PTC/STC ratio: 95.7% (rank #47).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.3 V at -10 C (573.0 V string) and 58.53 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,470 W STC

Occupies 35.1 m2 (378 sq ft) producing 8,107 W PTC; NEC 690.8 OCPD floor is 22.01 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.0 * (1 + (-0.232/100) * (-10 - 25)) = 57.3 V | OCPD = 1.56 * 14.11 = 22.01 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-605-BTA-BG: Voc=53.0 V, beta_Voc=-0.232%/C, Isc=14.11 A, STC=605.0 W, Area=2.51 m2.

**Result:** 10 panels max on 600 V (573.0 V); 14 panels for 8 kW (378 sq ft).

## What Are the Published CEC Specifications for SEG Solar Inc SEG-605-BTA-BG?

Complete CEC test sheet for SEG Solar Inc SEG-605-BTA-BG including Isc (14.11 A), Voc (53.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-605-BTA-BG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 605.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 579.1 W (95.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.11 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 45.01 V / 13.45 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.232 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 24.1% (2.51 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many SEG Solar Inc SEG-605-BTA-BG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SEG Solar Inc SEG-605-BTA-BG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.05 kW | 270 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 14 | 8.47 kW | 378 sq ft | $2,120 | $3,585 |
| **10 kW Class** | 17 | 10.29 kW | 459 sq ft | $2,575 | $4,355 |

## Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

Related SEG Solar Inc power steps and black/silver trims consolidated into this SEG Solar Inc SEG-605-BTA-BG series guide.

Sibling CEC listings grouped into the SEG Solar Inc SEG-605-BTA-BG wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SEG Solar Inc SEG-600-BTA-BG** | 600.0 W | 574.2 W | 52.8 V | 44.85 V | 23.9% |
| **SEG Solar Inc SEG-605-BTA-BG** | 605.0 W | 579.1 W | 53.0 V | 45.01 V | 24.1% |
| **SEG Solar Inc SEG-610-BTA-BG** | 610.0 W | 584.0 W | 53.2 V | 45.16 V | 24.3% |

## How Many SEG Solar Inc SEG-605-BTA-BG Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SEG Solar Inc SEG-605-BTA-BG (53.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=53.0V and beta_Voc=-0.232%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.53 V | 10 panels | 585.3 V | 17 panels |
| **-10 C (14 F)** | 57.3 V | 10 panels | 573.0 V | 17 panels |
| **0 C (32 F)** | 56.07 V | 10 panels | 560.7 V | 17 panels |
| **25 C (77 F STC)** | 53.0 V | 11 panels | 583.0 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-605-BTA-BG?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-144-BFN10-605W-DG (605.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-144-BFN10-605W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bfn10-605w-dg/) Aptos Solar Technology LLC | 605.0 W | Tie (0 W) | 52.9 V | 23.45% | 95.1% |
| [**BLUESUN GROUP LIMITED BSM605M10-72HNH**](https://epri-peac.com/solar-equipment/modules/bluesun-group-limited/bluesun-group-limited-bsm605m10-72hnh/) BLUESUN GROUP LIMITED | 605.0 W | Tie (0 W) | 52.9 V | 23.45% | 95.1% |
| [**JA Solar JAM78D30-605/MB**](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/) JA Solar | 605.0 W | Tie (0 W) | 53.61 V | 22.24% | 93.8% |
| [**LONGi Green Energy Technology Co Ltd LR5-78HBD-605M**](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-78hbd-605m/) LONGi Green Energy Technology Co Ltd | 605.0 W | Tie (0 W) | 54.2 V | 22.24% | 94.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-605-BTA-BG?

Evaluate SEG Solar Inc SEG-605-BTA-BG (605.0 W STC, 53.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-605-BTA-BG reaches 58.53 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 378 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-605-BTA-BG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SEG Solar Inc SEG-605-BTA-BG 8 kW Residential Fit

Needs 14 modules (378 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BFN10-605W-DG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 579.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-605-BTA-BG by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is SEG Solar Inc SEG-605-BTA-BG PTC wattage (579.1 W) lower than STC (605.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 579.1 W PTC (95.7% retention) across SEG Solar Inc SEG-605-BTA-BG's 2.51 m2 aperture.

### Who should skip SEG Solar Inc SEG-605-BTA-BG on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 SEG Solar Inc SEG-605-BTA-BG panels (378 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-BFN10-605W-DG.

### What is the 1,000 V commercial string limit for SEG Solar Inc SEG-605-BTA-BG?

On 1,000 V commercial inverters at -10 C (57.3 V cold Voc), SEG Solar Inc SEG-605-BTA-BG fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SEG Solar Inc SEG-605-BTA-BG.

## Related Pages

Compare SEG Solar Inc equipment, Aptos Solar Technology LLC DNA-144-BFN10-605W-DG specs, utility payback rates, and NEC string calculators alongside SEG Solar Inc SEG-605-BTA-BG.

[All SEG Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/seg-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SEG Solar Inc

- [All SEG Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/seg-solar-inc/)
- [SEG Solar Inc SEG-755-BHC-BG](https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-755-bhc-bg/)
- [SEG Solar Inc SEG-735-BHC-BG](https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-735-bhc-bg/)
- [SEG Solar Inc SEG-735-BTC-BG](https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-735-btc-bg/)
- [SEG Solar Inc SEG-715-BHC-BG](https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-715-bhc-bg/)
- [SEG Solar Inc SEG-710-BTC-BG](https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-710-btc-bg/)