title: "S-Energy Co Ltd SL65-54BHJ-395V Specs (395.0W, 37.03V Voc)"
url: https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl65-54bhj-395v/
description: "CEC datasheet for S-Energy Co Ltd SL65-54BHJ-395V: 395.0W STC, 37.03V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# S-Energy Co Ltd SL65-54BHJ-395V — CEC Solar Module Specifications

Manufacturer: [**S-Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

S-Energy Co Ltd SL65-54BHJ-395V is a 395.0 W STC (368.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 37.03 V Voc at 25 C, and 40.44 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 368.1 W

- **Voc @ 25C** : 37.03 V

- **Efficiency** : 20.36%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does S-Energy Co Ltd SL65-54BHJ-395V Compare Against Peer CEC Listings?

Solar engineering breakdown for S-Energy Co Ltd SL65-54BHJ-395V: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from S-Energy Co Ltd and peers, S-Energy Co Ltd SL65-54BHJ-395V stands 15.0 W below the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Lower 37.03 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does S-Energy Co Ltd SL65-54BHJ-395V Fall Across Listed CEC Models?

Distribution marker showing S-Energy Co Ltd SL65-54BHJ-395V (395.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define S-Energy Co Ltd SL65-54BHJ-395V?

Dataset percentiles tracking S-Energy Co Ltd SL65-54BHJ-395V power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for S-Energy Co Ltd SL65-54BHJ-395V?

Benchmark highlights for S-Energy Co Ltd SL65-54BHJ-395V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,064

### 20.36% Aperture Efficiency

Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.44 V at -10 C (566.2 V string) and 41.41 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 40.7 m2 (439 sq ft) producing 7,730 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.03 * (1 + (-0.263/100) * (-10 - 25)) = 40.44 V | OCPD = 1.56 * 13.59 = 21.2 A

Inputs from CEC Modules.csv for S-Energy Co Ltd SL65-54BHJ-395V: Voc=37.03 V, beta_Voc=-0.263%/C, Isc=13.59 A, STC=395.0 W, Area=1.94 m2.

**Result:** 14 panels max on 600 V (566.2 V); 21 panels for 8 kW (439 sq ft).

## What Are the Published CEC Specifications for S-Energy Co Ltd SL65-54BHJ-395V?

Official CEC datasheet figures for S-Energy Co Ltd SL65-54BHJ-395V (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for S-Energy Co Ltd SL65-54BHJ-395V.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 368.1 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.0 V / 12.75 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.263 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.36% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many S-Energy Co Ltd SL65-54BHJ-395V Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many S-Energy Co Ltd SL65-54BHJ-395V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 334 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 439 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 543 sq ft | $2,570 | $4,347 |

## How Many S-Energy Co Ltd SL65-54BHJ-395V Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on S-Energy Co Ltd SL65-54BHJ-395V (40.44 V at 14 F).

Computed from Voc=37.03V and beta_Voc=-0.263%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.41 V | 14 panels | 579.7 V | 24 panels |
| **-10 C (14 F)** | 40.44 V | 14 panels | 566.2 V | 24 panels |
| **0 C (32 F)** | 39.46 V | 15 panels | 591.9 V | 25 panels |
| **25 C (77 F STC)** | 37.03 V | 16 panels | 592.5 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SL65-54BHJ-395V?

Competing CEC solar panels closest to S-Energy Co Ltd SL65-54BHJ-395V in nameplate wattage and Voc, starting with Belinus Solar BV BE-M7-GG-108-395.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Belinus Solar BV BE-M7-GG-108-395**](https://epri-peac.com/solar-equipment/modules/belinus-solar-bv/belinus-solar-bv-be-m7-gg-108-395/) Belinus Solar BV | 395.0 W | Tie (0 W) | 37.03 V | 20.26% | 93.8% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-BF-395**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-bf-395/) Elin Energy (Sirius PV) | 395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.3% |
| [**AXITEC AC-395MBT/108V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-395mbt-108v/) AXITEC | 395.0 W | Tie (0 W) | 37.0 V | 20.47% | 93.3% |
| [**ASTORIOS Holding Inc ASTR108BDG-395W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr108bdg-395w-us/) ASTORIOS Holding Inc | 395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SL65-54BHJ-395V?

Evaluate S-Energy Co Ltd SL65-54BHJ-395V (395.0 W STC, 37.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SL65-54BHJ-395V reaches 41.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SL65-54BHJ-395V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### S-Energy Co Ltd SL65-54BHJ-395V 8 kW Residential Fit

Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Belinus Solar BV BE-M7-GG-108-395.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 368.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for S-Energy Co Ltd SL65-54BHJ-395V by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for S-Energy Co Ltd SL65-54BHJ-395V?

Multiplying S-Energy Co Ltd SL65-54BHJ-395V's 13.59 A short-circuit current by 1.56 equals 21.2 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can S-Energy Co Ltd SL65-54BHJ-395V pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.44 V cold Voc at 14 F and handles 13.59 A Isc; string inverters cap S-Energy Co Ltd SL65-54BHJ-395V at 14 panels on 600 V.

### Is S-Energy Co Ltd SL65-54BHJ-395V eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of S-Energy Co Ltd SL65-54BHJ-395V rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

## Related Pages

Compare S-Energy Co Ltd equipment, Belinus Solar BV BE-M7-GG-108-395 specs, utility payback rates, and NEC string calculators alongside S-Energy Co Ltd SL65-54BHJ-395V.

[All S-Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From S-Energy Co Ltd

- [All S-Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/)
- [S-Energy Co Ltd SL45-72MAI-460V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mai-460v/)
- [S-Energy Co Ltd SL45-72MCI-460V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mci-460v/)
- [S-Energy Co Ltd SL45-72BDI-455V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72bdi-455v/)
- [S-Energy Co Ltd SL45-72BDI-440V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72bdi-440v/)
- [S-Energy Co Ltd SL45-72MAI-440V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mai-440v/)