# S-Energy Co Ltd SL45-72MAI-440V — CEC Solar Module Specifications

Manufacturer: [**S-Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

S-Energy Co Ltd SL45-72MAI-440V is a 440.0 W STC (408.4 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.09% efficiency, 49.6 V Voc at 25 C, and 54.77 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 408.4 W

- **Voc @ 25C** : 49.6 V

- **Efficiency** : 20.09%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does S-Energy Co Ltd SL45-72MAI-440V Compare Against Peer CEC Listings?

Solar engineering breakdown for S-Energy Co Ltd SL45-72MAI-440V: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from S-Energy Co Ltd and peers, S-Energy Co Ltd SL45-72MAI-440V stands 30.0 W above the 410.0 W Mono-c-Si median and strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Higher 49.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does S-Energy Co Ltd SL45-72MAI-440V Fall Across Listed CEC Models?

Distribution marker showing S-Energy Co Ltd SL45-72MAI-440V (440.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define S-Energy Co Ltd SL45-72MAI-440V?

Dataset percentiles tracking S-Energy Co Ltd SL45-72MAI-440V power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for S-Energy Co Ltd SL45-72MAI-440V?

Benchmark highlights for S-Energy Co Ltd SL45-72MAI-440V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,188

### 20.09% Aperture Efficiency

Power density 200.9 W/m2 (0.18 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.77 V at -10 C (547.7 V string) and 56.25 V at -20 C (10 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 41.6 m2 (448 sq ft) producing 7,760 W PTC; NEC 690.8 OCPD floor is 17.69 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.298/100) * (-10 - 25)) = 54.77 V | OCPD = 1.56 * 11.34 = 17.69 A

Inputs from CEC Modules.csv for S-Energy Co Ltd SL45-72MAI-440V: Voc=49.6 V, beta_Voc=-0.298%/C, Isc=11.34 A, STC=440.0 W, Area=2.19 m2.

**Result:** 10 panels max on 600 V (547.7 V); 19 panels for 8 kW (448 sq ft).

## What Are the Published CEC Specifications for S-Energy Co Ltd SL45-72MAI-440V?

Official CEC datasheet figures for S-Energy Co Ltd SL45-72MAI-440V (Mono-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for S-Energy Co Ltd SL45-72MAI-440V.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 408.4 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.0 V / 10.74 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.298 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.09% (2.19 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many S-Energy Co Ltd SL45-72MAI-440V Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many S-Energy Co Ltd SL45-72MAI-440V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 330 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 448 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 542 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?

Consolidated S-Energy Co Ltd wattage variants sharing the S-Energy Co Ltd SL45-72MAI-440V mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the S-Energy Co Ltd SL45-72MAI-440V wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **S-Energy Co Ltd SL45-72MAI-430V** | 430.0 W | 398.9 W | 49.2 V | 40.6 V | 19.63% |
| **S-Energy Co Ltd SL45-72MAI-435V** | 435.0 W | 403.6 W | 49.4 V | 40.8 V | 19.86% |
| **S-Energy Co Ltd SL45-72MAI-440V** | 440.0 W | 408.4 W | 49.6 V | 41.0 V | 20.09% |
| **S-Energy Co Ltd SL45-72MAI-445V** | 445.0 W | 413.2 W | 49.8 V | 41.2 V | 20.32% |

## How Many S-Energy Co Ltd SL45-72MAI-440V Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on S-Energy Co Ltd SL45-72MAI-440V (54.77 V at 14 F).

Computed from Voc=49.6V and beta_Voc=-0.298%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.25 V | 10 panels | 562.5 V | 17 panels |
| **-10 C (14 F)** | 54.77 V | 10 panels | 547.7 V | 18 panels |
| **0 C (32 F)** | 53.3 V | 11 panels | 586.3 V | 18 panels |
| **25 C (77 F STC)** | 49.6 V | 12 panels | 595.2 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SL45-72MAI-440V?

Competing CEC solar panels closest to S-Energy Co Ltd SL45-72MAI-440V in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m144-hc-440w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 440.0 W | Tie (0 W) | 49.6 V | 20.75% | 92.4% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m144-bhc-440w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 440.0 W | Tie (0 W) | 49.3 V | 20.56% | 92.6% |
| [**Apollo Renewables Inc Apollo-M672BH-440TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m672bh-440tw/) Apollo Renewables Inc | 440.0 W | Tie (0 W) | 49.2 V | 20.47% | 93.4% |
| [**Bluesun Solar CoLtd BSM440M-72HPH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm440m-72hph/) Bluesun Solar CoLtd | 440.0 W | Tie (0 W) | 49.2 V | 20.28% | 92.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SL45-72MAI-440V?

Evaluate S-Energy Co Ltd SL45-72MAI-440V (440.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SL45-72MAI-440V reaches 56.25 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 448 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (448 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SL45-72MAI-440V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### S-Energy Co Ltd SL45-72MAI-440V 8 kW Residential Fit

Needs 19 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for S-Energy Co Ltd SL45-72MAI-440V by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for S-Energy Co Ltd SL45-72MAI-440V?

Multiplying S-Energy Co Ltd SL45-72MAI-440V's 11.34 A short-circuit current by 1.56 equals 17.69 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can S-Energy Co Ltd SL45-72MAI-440V pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.77 V cold Voc at 14 F and handles 11.34 A Isc; string inverters cap S-Energy Co Ltd SL45-72MAI-440V at 10 panels on 600 V.

### Is S-Energy Co Ltd SL45-72MAI-440V eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of S-Energy Co Ltd SL45-72MAI-440V rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

## Related Pages

Compare S-Energy Co Ltd equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W specs, utility payback rates, and NEC string calculators alongside S-Energy Co Ltd SL45-72MAI-440V.

[All S-Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From S-Energy Co Ltd

- [All S-Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/)
- [S-Energy Co Ltd SL45-72MAI-460V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mai-460v/)
- [S-Energy Co Ltd SL45-72MCI-460V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mci-460v/)
- [S-Energy Co Ltd SL45-72BDI-455V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72bdi-455v/)
- [S-Energy Co Ltd SL45-72BDI-440V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72bdi-440v/)
- [S-Energy Co Ltd SL45-72MCI-440V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mci-440v/)