title: "S-Energy Co Ltd SL40-72MAI-420V Specs (420.0W, 49.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl40-72mai-420v/
description: "CEC datasheet for S-Energy Co Ltd SL40-72MAI-420V: 420.0W STC, 49.8V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# S-Energy Co Ltd SL40-72MAI-420V — CEC Solar Module Specifications

Manufacturer: [**S-Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

S-Energy Co Ltd SL40-72MAI-420V is a 420.0 W STC (391.6 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 19.18% efficiency, 49.8 V Voc at 25 C, and 54.47 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 391.6 W

- **Voc @ 25C** : 49.8 V

- **Efficiency** : 19.18%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does S-Energy Co Ltd SL40-72MAI-420V Compare Against Peer CEC Listings?

Engineering position of S-Energy Co Ltd SL40-72MAI-420V (420.0 W STC) vs. DualSun SAS DualSun 420M-144-01 across 5,889 CEC Mono-c-Si solar modules.

Ranking #7,910 across 21,677 CEC solar panels (top 37.8%; higher than 62.2% of peers), S-Energy Co Ltd SL40-72MAI-420V operates as a modern high-density residential and light-commercial module sitting 10.0 W above the 410.0 W Mono-c-Si median. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677), 20 panels occupy 471 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does S-Energy Co Ltd SL40-72MAI-420V Fall Across Listed CEC Models?

Plots S-Energy Co Ltd SL40-72MAI-420V at 420.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define S-Energy Co Ltd SL40-72MAI-420V?

Benchmarks S-Energy Co Ltd SL40-72MAI-420V on STC wattage, thermal PTC/STC retention, and 19.18 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for S-Energy Co Ltd SL40-72MAI-420V?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for S-Energy Co Ltd SL40-72MAI-420V by S-Energy Co Ltd.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,034

### 19.18% Aperture Efficiency

Power density 191.8 W/m2 (0.73 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.47 V at -10 C (599.2 V string) and 55.81 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 43.8 m2 (471 sq ft) producing 7,832 W PTC; NEC 690.8 OCPD floor is 16.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.268/100) * (-10 - 25)) = 54.47 V | OCPD = 1.56 * 10.73 = 16.74 A

Inputs from CEC Modules.csv for S-Energy Co Ltd SL40-72MAI-420V: Voc=49.8 V, beta_Voc=-0.268%/C, Isc=10.73 A, STC=420.0 W, Area=2.19 m2.

**Result:** 11 panels max on 600 V (599.2 V); 20 panels for 8 kW (471 sq ft).

## What Are the Published CEC Specifications for S-Energy Co Ltd SL40-72MAI-420V?

Laboratory test ratings recorded for S-Energy Co Ltd SL40-72MAI-420V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for S-Energy Co Ltd SL40-72MAI-420V.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 391.6 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.5 V / 10.13 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.268 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.18% (2.19 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many S-Energy Co Ltd SL40-72MAI-420V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (471 sq ft at 8 kW), and estimated Year-1 electric bill offset for S-Energy Co Ltd SL40-72MAI-420V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 354 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 471 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 566 sq ft | $2,523 | $4,266 |

## How Many S-Energy Co Ltd SL40-72MAI-420V Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for S-Energy Co Ltd SL40-72MAI-420V (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.8V and beta_Voc=-0.268%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.81 V | 10 panels | 558.1 V | 17 panels |
| **-10 C (14 F)** | 54.47 V | 11 panels | 599.2 V | 18 panels |
| **0 C (32 F)** | 53.14 V | 11 panels | 584.5 V | 18 panels |
| **25 C (77 F STC)** | 49.8 V | 12 panels | 597.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SL40-72MAI-420V?

Closest cross-brand CEC competitors to S-Energy Co Ltd SL40-72MAI-420V matched near 420.0 W STC and 49.8 V Voc, led by DualSun SAS DualSun 420M-144-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DualSun SAS DualSun 420M-144-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-420m-144-01/) DualSun SAS | 420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| [**Auxin Solar AXNG1M410B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410b/) Auxin Solar | 410.0 W | -10.0 W | 49.47 V | 20.92% | 93.4% |
| [**Auxin Solar AXNG1M410W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410w/) Auxin Solar | 410.0 W | -10.0 W | 49.47 V | 20.92% | 93.3% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m872w-410w/) Dehui Solar Power (Vietnam) CoLtd | 410.0 W | -10.0 W | 49.4 V | 21.47% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SL40-72MAI-420V?

Evaluate S-Energy Co Ltd SL40-72MAI-420V (420.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SL40-72MAI-420V reaches 55.81 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 471 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (471 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SL40-72MAI-420V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### S-Energy Co Ltd SL40-72MAI-420V 8 kW Residential Fit

Needs 20 modules (471 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for S-Energy Co Ltd SL40-72MAI-420V by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### How many S-Energy Co Ltd SL40-72MAI-420V panels fit on a 600 V winter solar string?

At -10 C (14 F), S-Energy Co Ltd SL40-72MAI-420V cold Voc rises from 49.8 V to 54.47 V (beta_Voc -0.268%/C), capping a 600 V string at 11 panels (599.2 V).

### How much roof area does an 8 kW array of S-Energy Co Ltd SL40-72MAI-420V need?

An 8 kW DC system uses 20 S-Energy Co Ltd SL40-72MAI-420V modules (8,400 W STC / 7,832 W PTC), covering roughly 471 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

### How does S-Energy Co Ltd SL40-72MAI-420V compare against DualSun SAS DualSun 420M-144-01?

S-Energy Co Ltd SL40-72MAI-420V outputs 420.0 W STC (49.8 V Voc, rank #7,910 of 21,677), while DualSun SAS DualSun 420M-144-01 delivers 420.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare S-Energy Co Ltd equipment, DualSun SAS DualSun 420M-144-01 specs, utility payback rates, and NEC string calculators alongside S-Energy Co Ltd SL40-72MAI-420V.

[All S-Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From S-Energy Co Ltd

- [All S-Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/s-energy-co-ltd/)
- [S-Energy Co Ltd SL45-72MAI-460V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mai-460v/)
- [S-Energy Co Ltd SL45-72MCI-460V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72mci-460v/)
- [S-Energy Co Ltd SL45-72BDI-455V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72bdi-455v/)
- [S-Energy Co Ltd SL45-72BDI-440V](https://epri-peac.com/solar-equipment/modules/s-energy-co-ltd/s-energy-co-ltd-sl45-72bdi-440v/)