---
title: "Risen Energy Co Ltd SYP280P Specs (280.0W, 44.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-syp280p/
description: "CEC datasheet for Risen Energy Co Ltd SYP280P: 280.0W STC, 44.8V Voc, 29-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Risen Energy Co Ltd SYP280P — CEC Solar Module Specifications

Manufacturer: [**Risen Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/risen-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

Risen Energy Co Ltd SYP280P is a 280.0 W STC (246.6 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 14.43% efficiency, 44.8 V Voc at 25 C, and 51.01 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 280.0 W

- **PTC Wattage** : 246.6 W

- **Voc @ 25C** : 44.8 V

- **Efficiency** : 14.43%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Risen Energy Co Ltd SYP280P Compare Against Peer CEC Listings?

Solar engineering breakdown for Risen Energy Co Ltd SYP280P: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 280.0 W STC and 246.6 W PTC, Risen Energy Co Ltd SYP280P sits -105.0 W vs all-CEC median (below all-CEC median; higher than 15.8% of peers) among 21,677 listed modules. Power density reaches 144.3 W/m2 (5.48 percentage points below 19.91% CEC median). Mid-range 44.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Gintung Energy ASEC-285G6S rates 285.0 W.

## Where Does Risen Energy Co Ltd SYP280P Fall Across Listed CEC Models?

Distribution marker showing Risen Energy Co Ltd SYP280P (280.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Risen Energy Co Ltd SYP280P?

Dataset percentiles tracking Risen Energy Co Ltd SYP280P power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Risen Energy Co Ltd SYP280P?

Benchmark highlights for Risen Energy Co Ltd SYP280P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #17,941 / 21,677

### 280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,485

### 14.43% Aperture Efficiency

Power density 144.3 W/m2 (5.48 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.01 V at -10 C (561.1 V string) and 52.78 V at -20 C (11 max).

 8 kW Reference Array

### 29 Panels = 8,120 W STC

Occupies 56.3 m2 (606 sq ft) producing 7,151 W PTC; NEC 690.8 OCPD floor is 12.99 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.396/100) * (-10 - 25)) = 51.01 V | OCPD = 1.56 * 8.33 = 12.99 A

Inputs from CEC Modules.csv for Risen Energy Co Ltd SYP280P: Voc=44.8 V, beta_Voc=-0.396%/C, Isc=8.33 A, STC=280.0 W, Area=1.94 m2.

**Result:** 11 panels max on 600 V (561.1 V); 29 panels for 8 kW (606 sq ft).

## What Are the Published CEC Specifications for Risen Energy Co Ltd SYP280P?

Official CEC datasheet figures for Risen Energy Co Ltd SYP280P (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Risen Energy Co Ltd SYP280P.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 246.6 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.2 V / 7.95 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.396 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.43% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Risen Energy Co Ltd SYP280P Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Risen Energy Co Ltd SYP280P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 22 | 6.16 kW | 459 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 29 | 8.12 kW | 606 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 36 | 10.08 kW | 752 sq ft | $2,523 | $4,266 |

## How Many Risen Energy Co Ltd SYP280P Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Risen Energy Co Ltd SYP280P (51.01 V at 14 F).

Computed from Voc=44.8V and beta_Voc=-0.396%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.78 V | 11 panels | 580.6 V | 18 panels |
| **-10 C (14 F)** | 51.01 V | 11 panels | 561.1 V | 19 panels |
| **0 C (32 F)** | 49.24 V | 12 panels | 590.9 V | 20 panels |
| **25 C (77 F STC)** | 44.8 V | 13 panels | 582.4 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Risen Energy Co Ltd SYP280P?

Competing CEC solar panels closest to Risen Energy Co Ltd SYP280P in nameplate wattage and Voc, starting with Gintung Energy ASEC-285G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-285G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6s/) Gintung Energy | 285.0 W | +5.0 W | 44.69 V | 14.57% | 89.7% |
| [**Gintung Energy ASEC-285G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-285g6m/) Gintung Energy | 285.0 W | +5.0 W | 44.53 V | 14.57% | 89.5% |
| [**AXITEC AC-285P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-285p-156-72s/) AXITEC | 285.0 W | +5.0 W | 44.51 V | 14.72% | 90.0% |
| [**Centrosolar America DP72 285**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-285/) Centrosolar America | 285.0 W | +5.0 W | 44.32 V | 14.66% | 88.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Risen Energy Co Ltd SYP280P?

Evaluate Risen Energy Co Ltd SYP280P (280.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Risen Energy Co Ltd SYP280P reaches 52.78 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft).
- 2026 tax credit baseline: cash residential installs of Risen Energy Co Ltd SYP280P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Risen Energy Co Ltd SYP280P 8 kW Residential Fit

Needs 29 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-285G6S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 246.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Risen Energy Co Ltd SYP280P by Risen Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Risen Energy Co Ltd SYP280P panels fit on a 600 V winter solar string?

At -10 C (14 F), Risen Energy Co Ltd SYP280P cold Voc rises from 44.8 V to 51.01 V (beta_Voc -0.396%/C), capping a 600 V string at 11 panels (561.1 V).

### How much roof area does an 8 kW array of Risen Energy Co Ltd SYP280P need?

An 8 kW DC system uses 29 Risen Energy Co Ltd SYP280P modules (8,120 W STC / 7,151 W PTC), covering roughly 606 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

### How does Risen Energy Co Ltd SYP280P compare against Gintung Energy ASEC-285G6S?

Risen Energy Co Ltd SYP280P outputs 280.0 W STC (44.8 V Voc, rank #17,941 of 21,677), while Gintung Energy ASEC-285G6S delivers 285.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Risen Energy Co Ltd equipment, Gintung Energy ASEC-285G6S specs, utility payback rates, and NEC string calculators alongside Risen Energy Co Ltd SYP280P.

[All Risen Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/risen-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Risen Energy Co Ltd

- [All Risen Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/risen-energy-co-ltd/)
- [Risen Energy Co Ltd RSM132-8-730BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-730bhdg/)
- [Risen Energy Co Ltd RSM132-8-710BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-710bhdg/)
- [Risen Energy Co Ltd RSM132-8-685BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-685bhdg/)
- [Risen Energy Co Ltd RSM132-8-660BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-660bhdg/)
- [Risen Energy Co Ltd RSM132-8-660BMDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-660bmdg/)
