title: "Risen Energy Co Ltd RSM144-6-385M Specs (385.0W, 48.15V Voc)"
url: https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm144-6-385m/
description: "CEC datasheet for Risen Energy Co Ltd RSM144-6-385M: 385.0W STC, 48.15V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Risen Energy Co Ltd RSM144-6-385M — CEC Solar Module Specifications

Manufacturer: [**Risen Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/risen-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

Risen Energy Co Ltd RSM144-6-385M is a 385.0 W STC (356.6 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.15% efficiency, 48.15 V Voc at 25 C, and 52.41 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 356.6 W

- **Voc @ 25C** : 48.15 V

- **Efficiency** : 19.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Risen Energy Co Ltd RSM144-6-385M Compare Against Peer CEC Listings?

How Risen Energy Co Ltd Risen Energy Co Ltd RSM144-6-385M handles rooftop heat (356.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Risen Energy Co Ltd RSM144-6-385M exhibits 10.2 A short-circuit current, requiring a 15.91 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #10,723 of 21,677 (25.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 42.2 m2 for an 8 kW system (26 panels for 10 kW). Higher 48.15 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does Risen Energy Co Ltd RSM144-6-385M Fall Across Listed CEC Models?

Where Risen Energy Co Ltd RSM144-6-385M (385.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Risen Energy Co Ltd RSM144-6-385M?

Percentile placement of Risen Energy Co Ltd RSM144-6-385M across power density (191.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Risen Energy Co Ltd RSM144-6-385M?

Four critical engineering numbers homeowners and solar installers check first when reviewing Risen Energy Co Ltd RSM144-6-385M specifications.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,087

### 19.15% Aperture Efficiency

Power density 191.5 W/m2 (0.76 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.41 V at -10 C (576.5 V string) and 53.63 V at -20 C (11 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 42.2 m2 (454 sq ft) producing 7,489 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.15 * (1 + (-0.253/100) * (-10 - 25)) = 52.41 V | OCPD = 1.56 * 10.2 = 15.91 A

Inputs from CEC Modules.csv for Risen Energy Co Ltd RSM144-6-385M: Voc=48.15 V, beta_Voc=-0.253%/C, Isc=10.2 A, STC=385.0 W, Area=2.01 m2.

**Result:** 11 panels max on 600 V (576.5 V); 21 panels for 8 kW (454 sq ft).

## What Are the Published CEC Specifications for Risen Energy Co Ltd RSM144-6-385M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Risen Energy Co Ltd RSM144-6-385M.

Official California Energy Commission (NREL SAM) test parameters for Risen Energy Co Ltd RSM144-6-385M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 356.6 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.15 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.15 V / 9.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.253 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.15% (2.01 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Risen Energy Co Ltd RSM144-6-385M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Risen Energy Co Ltd RSM144-6-385M (385.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 346 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 454 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 563 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Risen Energy Co Ltd Series?

All closely matched Risen Energy Co Ltd wattages and cosmetic trims sharing the Risen Energy Co Ltd RSM144-6-385M architecture.

Sibling CEC listings grouped into the Risen Energy Co Ltd RSM144-6-385M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Risen Energy Co Ltd RSM144-6-375M** | 375.0 W | 347.1 W | 47.85 V | 39.95 V | 18.66% |
| **Risen Energy Co Ltd RSM144-6-380M** | 380.0 W | 351.8 W | 48.0 V | 40.05 V | 18.91% |
| **Risen Energy Co Ltd RSM144-6-385M** | 385.0 W | 356.6 W | 48.15 V | 40.15 V | 19.15% |
| **Risen Energy Co Ltd RSM144-6-390M** | 390.0 W | 361.3 W | 48.3 V | 40.25 V | 19.4% |
| **Risen Energy Co Ltd RSM144-6-395M** | 395.0 W | 366.1 W | 48.45 V | 40.35 V | 19.65% |

## How Many Risen Energy Co Ltd RSM144-6-385M Modules Fit in a Cold-Weather String?

Maximum series module counts for Risen Energy Co Ltd RSM144-6-385M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.15V and beta_Voc=-0.253%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.63 V | 11 panels | 589.9 V | 18 panels |
| **-10 C (14 F)** | 52.41 V | 11 panels | 576.5 V | 19 panels |
| **0 C (32 F)** | 51.2 V | 11 panels | 563.2 V | 19 panels |
| **25 C (77 F STC)** | 48.15 V | 12 panels | 577.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Risen Energy Co Ltd RSM144-6-385M?

Alternative CEC solar modules from competing brands near Risen Energy Co Ltd RSM144-6-385M (385.0 W), including AXITEC AC-385MH/144S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-385MH/144S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-385mh-144s/) AXITEC | 385.0 W | Tie (0 W) | 48.0 V | 19.41% | 92.9% |
| [**AXITEC AC-385MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-385mh-144v/) AXITEC | 385.0 W | Tie (0 W) | 48.0 V | 19.41% | 92.9% |
| [**CSI Solar Co Ltd CS3U-385P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-385p/) CSI Solar Co Ltd | 385.0 W | Tie (0 W) | 48.0 V | 20.05% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Risen Energy Co Ltd RSM144-6-385M?

Evaluate Risen Energy Co Ltd RSM144-6-385M (385.0 W STC, 48.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Risen Energy Co Ltd RSM144-6-385M reaches 53.63 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 454 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (454 sq ft).
- 2026 tax credit baseline: cash residential installs of Risen Energy Co Ltd RSM144-6-385M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Risen Energy Co Ltd RSM144-6-385M 8 kW Residential Fit

Needs 21 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-385MH/144S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 356.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Risen Energy Co Ltd RSM144-6-385M by Risen Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Risen Energy Co Ltd RSM144-6-385M PTC wattage (356.6 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 356.6 W PTC (92.6% retention) across Risen Energy Co Ltd RSM144-6-385M's 2.01 m2 aperture.

### Who should skip Risen Energy Co Ltd RSM144-6-385M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Risen Energy Co Ltd RSM144-6-385M panels (454 sq ft) leave unusable roof gaps vs. AXITEC AC-385MH/144S.

### What is the 1,000 V commercial string limit for Risen Energy Co Ltd RSM144-6-385M?

On 1,000 V commercial inverters at -10 C (52.41 V cold Voc), Risen Energy Co Ltd RSM144-6-385M fits up to 19 panels per series string.

## Related Pages

Compare Risen Energy Co Ltd equipment, AXITEC AC-385MH/144S specs, utility payback rates, and NEC string calculators alongside Risen Energy Co Ltd RSM144-6-385M.

[All Risen Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/risen-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Risen Energy Co Ltd

- [All Risen Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/risen-energy-co-ltd/)
- [Risen Energy Co Ltd RSM132-8-730BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-730bhdg/)
- [Risen Energy Co Ltd RSM132-8-710BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-710bhdg/)
- [Risen Energy Co Ltd RSM132-8-685BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-685bhdg/)
- [Risen Energy Co Ltd RSM132-8-660BHDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-660bhdg/)
- [Risen Energy Co Ltd RSM132-8-660BMDG](https://epri-peac.com/solar-equipment/modules/risen-energy-co-ltd/risen-energy-co-ltd-rsm132-8-660bmdg/)