# Renesola America JC315S-24/Abh — CEC Solar Module Specifications

Manufacturer: [**Renesola America**](https://epri-peac.com/solar-equipment/brands/renesola-america/) Registry: **CEC Verified Engineering Specification**

Renesola America JC315S-24/Abh is a 315.0 W STC (288.9 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.23% efficiency, 46.0 V Voc at 25 C, and 52.63 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 315.0 W

- **PTC Wattage** : 288.9 W

- **Voc @ 25C** : 46.0 V

- **Efficiency** : 16.23%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Renesola America JC315S-24/Abh Compare Against Peer CEC Listings?

How Renesola America Renesola America JC315S-24/Abh handles rooftop heat (288.9 W PTC), 8 kW sizing, and cold winter string voltage.

Renesola America builds the Renesola America JC315S-24/Abh (Mono-c-Si) as a compact residential or specialty off-grid module delivering 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612M-315 (315.0 W), this model holds strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677). Mid-range 46.0 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.95 A overcurrent floor served by a 15 A breaker.

## Where Does Renesola America JC315S-24/Abh Fall Across Listed CEC Models?

Where Renesola America JC315S-24/Abh (315.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Renesola America JC315S-24/Abh?

Percentile placement of Renesola America JC315S-24/Abh across power density (162.4 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Renesola America JC315S-24/Abh?

Four critical engineering numbers homeowners and solar installers check first when reviewing Renesola America JC315S-24/Abh specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #15,387 / 21,677

### 315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,776

### 16.23% Aperture Efficiency

Power density 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.63 V at -10 C (578.9 V string) and 54.53 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,190 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,511 W PTC; NEC 690.8 OCPD floor is 13.95 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.0 * (1 + (-0.412/100) * (-10 - 25)) = 52.63 V | OCPD = 1.56 * 8.94 = 13.95 A

Inputs from CEC Modules.csv for Renesola America JC315S-24/Abh: Voc=46.0 V, beta_Voc=-0.412%/C, Isc=8.94 A, STC=315.0 W, Area=1.94 m2.

**Result:** 11 panels max on 600 V (578.9 V); 26 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for Renesola America JC315S-24/Abh?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Renesola America JC315S-24/Abh.

Official California Energy Commission (NREL SAM) test parameters for Renesola America JC315S-24/Abh.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 288.9 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 46.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.3 V / 8.68 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.412 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.23% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Renesola America JC315S-24/Abh Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Renesola America JC315S-24/Abh (315.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.3 kW | 418 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 26 | 8.19 kW | 543 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 32 | 10.08 kW | 668 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Renesola America Series?

All closely matched Renesola America wattages and cosmetic trims sharing the Renesola America JC315S-24/Abh architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Renesola America JC315S-24/Abh wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Renesola America JC300S-24/Abh** | 300.0 W | 274.8 W | 45.4 V | 35.8 V | 15.46% |
| **Renesola America JC310S-24/Abh** | 310.0 W | 284.2 W | 45.8 V | 36.1 V | 15.98% |
| **Renesola America JC315S-24/Abh** | 315.0 W | 288.9 W | 46.0 V | 36.3 V | 16.23% |
| **Renesola America JC320S-24/Abh** | 320.0 W | 293.6 W | 46.1 V | 36.5 V | 16.49% |

## How Many Renesola America JC315S-24/Abh Modules Fit in a Cold-Weather String?

Maximum series module counts for Renesola America JC315S-24/Abh from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.0V and beta_Voc=-0.412%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.53 V | 11 panels | 599.8 V | 18 panels |
| **-10 C (14 F)** | 52.63 V | 11 panels | 578.9 V | 19 panels |
| **0 C (32 F)** | 50.74 V | 11 panels | 558.1 V | 19 panels |
| **25 C (77 F STC)** | 46.0 V | 13 panels | 598.0 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Renesola America JC315S-24/Abh?

Alternative CEC solar modules from competing brands near Renesola America JC315S-24/Abh (315.0 W), including Boviet Solar Technology Co Ltd BVM6612M-315.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-315**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-315/) Boviet Solar Technology Co Ltd | 315.0 W | Tie (0 W) | 46.1 V | 16.23% | 90.5% |
| [**Centrosolar America EP72 315BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep72-315bw/) Centrosolar America | 315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
| [**Centrosolar America EP72 315SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep72-315sw/) Centrosolar America | 315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
| [**GCL System Integration Technology Co Ltd GCL-P6/72315**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-72315/) GCL System Integration Technology Co Ltd | 315.0 W | Tie (0 W) | 45.6 V | 16.23% | 90.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Renesola America JC315S-24/Abh?

Evaluate Renesola America JC315S-24/Abh (315.0 W STC, 46.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Renesola America JC315S-24/Abh reaches 54.53 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Renesola America JC315S-24/Abh carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Renesola America JC315S-24/Abh 8 kW Residential Fit

Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-315.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Renesola America JC315S-24/Abh by Renesola America grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Renesola America JC315S-24/Abh?

Multiplying Renesola America JC315S-24/Abh's 8.94 A short-circuit current by 1.56 equals 13.95 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Renesola America JC315S-24/Abh pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.63 V cold Voc at 14 F and handles 8.94 A Isc; string inverters cap Renesola America JC315S-24/Abh at 11 panels on 600 V.

### Is Renesola America JC315S-24/Abh eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Renesola America JC315S-24/Abh rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Renesola America equipment, Boviet Solar Technology Co Ltd BVM6612M-315 specs, utility payback rates, and NEC string calculators alongside Renesola America JC315S-24/Abh.

[All Renesola America Certified Solar Models](https://epri-peac.com/solar-equipment/brands/renesola-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Renesola America

- [All Renesola America Specs](https://epri-peac.com/solar-equipment/brands/renesola-america/)
- [Renesola America JC330M-24/Abs](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-abs/)
- [Renesola America JC330M-24/Abs-b](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-abs-b/)
- [Renesola America JC330M-24/Azs](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-azs/)
- [Renesola America JC330M-24/Azs-b](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-azs-b/)
- [Renesola America JC315M-24/Abs](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc315m-24-abs/)