Renesola America JC265M-24/Bzs-b is a 265.0 W STC (240.2 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.29% efficiency, 37.7 V Voc at 25 C, and 42.07 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 265.0 W

- **PTC Wattage** : 240.2 W

- **Voc @ 25C** : 37.7 V

- **Efficiency** : 16.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Renesola America JC265M-24/Bzs-b Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Renesola America JC265M-24/Bzs-b (Multi-c-Si) residential solar systems.

Homeowners evaluating Renesola America JC265M-24/Bzs-b need 23 panels for 6 kW or 31 panels (543 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft). Under NEC 690.7(A), beta_Voc (-0.331%/C) pushes open-circuit voltage to 42.07 V at 14 F and 43.32 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Renesola America JC265M-24/Bzs-b Fall Across Listed CEC Models?

Comparison of Renesola America JC265M-24/Bzs-b (265.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Renesola America JC265M-24/Bzs-b?

Relative ranking of Renesola America JC265M-24/Bzs-b across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Renesola America JC265M-24/Bzs-b?

Summary of Renesola America JC265M-24/Bzs-b output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.

Rank #18,880 / 21,677

### 265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,670

### 16.29% Aperture Efficiency

Power density 162.9 W/m2 (3.62 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.07 V at -10 C (589.0 V string) and 43.32 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,215 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,446 W PTC; NEC 690.8 OCPD floor is 14.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.7 * (1 + (-0.331/100) * (-10 - 25)) = 42.07 V | OCPD = 1.56 * 9.03 = 14.09 A

Inputs from CEC Modules.csv for Renesola America JC265M-24/Bzs-b: Voc=37.7 V, beta_Voc=-0.331%/C, Isc=9.03 A, STC=265.0 W, Area=1.627 m2.

**Result:** 14 panels max on 600 V (589.0 V); 31 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for Renesola America JC265M-24/Bzs-b?

Complete CEC test sheet for Renesola America JC265M-24/Bzs-b including Isc (9.03 A), Voc (37.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Renesola America JC265M-24/Bzs-b.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 240.2 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.03 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.6 V / 8.66 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.331 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.29% (1.627 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Renesola America JC265M-24/Bzs-b Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Renesola America JC265M-24/Bzs-b.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.09 kW | 403 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 31 | 8.21 kW | 543 sq ft | $2,055 | $3,475 |
| **10 kW Class** | 38 | 10.07 kW | 665 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This Renesola America Series?

Related Renesola America power steps and black/silver trims consolidated into this Renesola America JC265M-24/Bzs-b series guide.

Sibling CEC listings grouped into the Renesola America JC265M-24/Bzs-b wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Renesola America JC260M-24/Bzs-b** | 260.0 W | 235.6 W | 37.6 V | 30.5 V | 15.98% |
| **Renesola America JC265M-24/Bzs-b** | 265.0 W | 240.2 W | 37.7 V | 30.6 V | 16.29% |
| **Renesola America JC270M-24/Bzs-b** | 270.0 W | 244.9 W | 38.1 V | 31.0 V | 16.6% |

## How Many Renesola America JC265M-24/Bzs-b Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Renesola America JC265M-24/Bzs-b (37.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.7V and beta_Voc=-0.331%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.32 V | 13 panels | 563.2 V | 23 panels |
| **-10 C (14 F)** | 42.07 V | 14 panels | 589.0 V | 23 panels |
| **0 C (32 F)** | 40.82 V | 14 panels | 571.5 V | 24 panels |
| **25 C (77 F STC)** | 37.7 V | 15 panels | 565.5 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Renesola America JC265M-24/Bzs-b?

Four comparable CEC modules such as Centrosolar America TM6 265xx (265.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America TM6 265xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6-265xx/) Centrosolar America | 265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| [**Centrosolar America TM6S 265xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6s-265xx/) Centrosolar America | 265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60265**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60265/) GCL System Integration Technology Co Ltd | 265.0 W | Tie (0 W) | 38.1 V | 16.29% | 90.5% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60B265**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60b265/) GCL System Integration Technology Co Ltd | 265.0 W | Tie (0 W) | 38.1 V | 16.26% | 90.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Renesola America JC265M-24/Bzs-b?

Evaluate Renesola America JC265M-24/Bzs-b (265.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Renesola America JC265M-24/Bzs-b reaches 43.32 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Renesola America JC265M-24/Bzs-b carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Renesola America JC265M-24/Bzs-b 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 265xx.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 240.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Renesola America JC265M-24/Bzs-b by Renesola America grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Renesola America JC265M-24/Bzs-b PTC wattage (240.2 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 240.2 W PTC (90.6% retention) across Renesola America JC265M-24/Bzs-b's 1.627 m2 aperture.

### Who should skip Renesola America JC265M-24/Bzs-b on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Renesola America JC265M-24/Bzs-b panels (543 sq ft) leave unusable roof gaps vs. Centrosolar America TM6 265xx.

### What is the 1,000 V commercial string limit for Renesola America JC265M-24/Bzs-b?

On 1,000 V commercial inverters at -10 C (42.07 V cold Voc), Renesola America JC265M-24/Bzs-b fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Renesola America JC265M-24/Bzs-b.

## Related Pages

Compare Renesola America equipment, Centrosolar America TM6 265xx specs, utility payback rates, and NEC string calculators alongside Renesola America JC265M-24/Bzs-b.

[All Renesola America Certified Solar Models](https://epri-peac.com/solar-equipment/brands/renesola-america/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Renesola America

- [All Renesola America Specs](https://epri-peac.com/solar-equipment/brands/renesola-america/)
- [Renesola America JC330M-24/Abs](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-abs/)
- [Renesola America JC330M-24/Abs-b](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-abs-b/)
- [Renesola America JC330M-24/Azs](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-azs/)
- [Renesola America JC330M-24/Azs-b](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc330m-24-azs-b/)
- [Renesola America JC315M-24/Abs](https://epri-peac.com/solar-equipment/modules/renesola-america/renesola-america-jc315m-24-abs/)