title: "Regitec Solar BV RMHT72/565S3 Specs (580.0W, 50.87V Voc)"
url: https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s3/
description: "CEC datasheet for Regitec Solar BV RMHT72/565S3: 580.0W STC, 50.87V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Regitec Solar BV RMHT72/565S3 — CEC Solar Module Specifications

Manufacturer: [**Regitec Solar BV**](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) Registry: **CEC Verified Engineering Specification**

Regitec Solar BV RMHT72/565S3 is a 580.0 W STC (545.2 W PTC) Mono-c-Si solar module ranking #1,885 of 21,677 CEC listings (top 9.4%; higher than 90.6% of peers). It delivers 22.48% efficiency, 50.87 V Voc at 25 C, and 55.27 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 580.0 W

- **PTC Wattage** : 545.2 W

- **Voc @ 25C** : 50.87 V

- **Efficiency** : 22.48%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Regitec Solar BV RMHT72/565S3 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Regitec Solar BV RMHT72/565S3 (Mono-c-Si) residential solar systems.

Homeowners evaluating Regitec Solar BV RMHT72/565S3 need 11 panels for 6 kW or 14 panels (389 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.247%/C) pushes open-circuit voltage to 55.27 V at 14 F and 56.52 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Regitec Solar BV RMHT72/565S3 Fall Across Listed CEC Models?

Comparison of Regitec Solar BV RMHT72/565S3 (580.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Regitec Solar BV RMHT72/565S3?

Relative ranking of Regitec Solar BV RMHT72/565S3 across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Regitec Solar BV RMHT72/565S3?

Summary of Regitec Solar BV RMHT72/565S3 output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,885 / 21,677

### Top 9.4% STC Output

580.0 W STC (+195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,050

### 22.48% Aperture Efficiency

Power density 224.8 W/m2 (2.57 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.27 V at -10 C (552.7 V string) and 56.52 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,120 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,633 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.87 * (1 + (-0.247/100) * (-10 - 25)) = 55.27 V | OCPD = 1.56 * 14.19 = 22.14 A

Inputs from CEC Modules.csv for Regitec Solar BV RMHT72/565S3: Voc=50.87 V, beta_Voc=-0.247%/C, Isc=14.19 A, STC=580.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (552.7 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for Regitec Solar BV RMHT72/565S3?

Complete CEC test sheet for Regitec Solar BV RMHT72/565S3 including Isc (14.19 A), Voc (50.87 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Regitec Solar BV RMHT72/565S3.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 580.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 545.2 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.87 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.14 V / 13.41 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.247 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.48% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Regitec Solar BV RMHT72/565S3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Regitec Solar BV RMHT72/565S3.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.38 kW | 305 sq ft | $1,597 | $2,700 |
| **8 kW Class** | 14 | 8.12 kW | 389 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 18 | 10.44 kW | 500 sq ft | $2,613 | $4,418 |

## How Many Regitec Solar BV RMHT72/565S3 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Regitec Solar BV RMHT72/565S3 (50.87 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.87V and beta_Voc=-0.247%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.52 V | 10 panels | 565.2 V | 17 panels |
| **-10 C (14 F)** | 55.27 V | 10 panels | 552.7 V | 18 panels |
| **0 C (32 F)** | 54.01 V | 11 panels | 594.1 V | 18 panels |
| **25 C (77 F STC)** | 50.87 V | 11 panels | 559.6 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMHT72/565S3?

Four comparable CEC modules such as BYD Company Limited BYD580NLBK-36 (580.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**BYD Company Limited BYD580NLBK-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd580nlbk-36/) BYD Company Limited | 580.0 W | Tie (0 W) | 51.01 V | 22.48% | 94.8% |
| [**Aptos Solar Technology LLC DNA-144-BFN10-580W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bfn10-580w-dg/) Aptos Solar Technology LLC | 580.0 W | Tie (0 W) | 51.02 V | 22.48% | 94.9% |
| [**EMMVEE Photovoltaic Power Private Limited E575HCMW144-T**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e575hcmw144-t/) EMMVEE Photovoltaic Power Private Limited | 575.0 W | -5.0 W | 51.27 V | 22.46% | 94.4% |
| [**Chint New Energy Technology Co Ltd CHSM72N-HC-585**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72n-hc-585/) Chint New Energy Technology Co Ltd | 585.0 W | +5.0 W | 51.3 V | 22.67% | 94.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMHT72/565S3?

Evaluate Regitec Solar BV RMHT72/565S3 (580.0 W STC, 50.87 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMHT72/565S3 reaches 56.52 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMHT72/565S3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Regitec Solar BV RMHT72/565S3 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare BYD Company Limited BYD580NLBK-36.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 545.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Regitec Solar BV RMHT72/565S3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Regitec Solar BV RMHT72/565S3 PTC wattage (545.2 W) lower than STC (580.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 545.2 W PTC (94.0% retention) across Regitec Solar BV RMHT72/565S3's 2.58 m2 aperture.

### Who should skip Regitec Solar BV RMHT72/565S3 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Regitec Solar BV RMHT72/565S3 panels (389 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD580NLBK-36.

### What is the 1,000 V commercial string limit for Regitec Solar BV RMHT72/565S3?

On 1,000 V commercial inverters at -10 C (55.27 V cold Voc), Regitec Solar BV RMHT72/565S3 fits up to 18 panels per series string.

## Related Pages

Compare Regitec Solar BV equipment, BYD Company Limited BYD580NLBK-36 specs, utility payback rates, and NEC string calculators alongside Regitec Solar BV RMHT72/565S3.

[All Regitec Solar BV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Regitec Solar BV

- [All Regitec Solar BV Specs](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/)
- [Regitec Solar BV RMHT72/565S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s1/)
- [Regitec Solar BV RMHT72/575S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-575s2/)
- [Regitec Solar BV RMHT72/570S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s1/)
- [Regitec Solar BV RMHT72/570S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s2/)