Manufacturer: [**Regitec Solar BV**](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) Registry: **CEC Verified Engineering Specification**

Regitec Solar BV RMHT54/425AB3 is a 425.0 W STC (399.2 W PTC) Mono-c-Si solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 21.79% efficiency, 38.3 V Voc at 25 C, and 41.61 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 425.0 W

- **PTC Wattage** : 399.2 W

- **Voc @ 25C** : 38.3 V

- **Efficiency** : 21.79%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Regitec Solar BV RMHT54/425AB3 Compare Against Peer CEC Listings?

How Regitec Solar BV Regitec Solar BV RMHT54/425AB3 handles rooftop heat (399.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Regitec Solar BV RMHT54/425AB3 exhibits 14.15 A short-circuit current, requiring a 22.07 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #7,622 of 21,677 (15.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 37.0 m2 for an 8 kW system (24 panels for 10 kW). Lower 38.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Regitec Solar BV RMHT54/425AB3 Fall Across Listed CEC Models?

Where Regitec Solar BV RMHT54/425AB3 (425.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Regitec Solar BV RMHT54/425AB3?

Percentile placement of Regitec Solar BV RMHT54/425AB3 across power density (217.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Regitec Solar BV RMHT54/425AB3?

Four critical engineering numbers homeowners and solar installers check first when reviewing Regitec Solar BV RMHT54/425AB3 specifications.

Rank #7,622 / 21,677

### Top 36.5% STC Output

425.0 W STC (+40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,590

### 21.79% Aperture Efficiency

Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.61 V at -10 C (582.5 V string) and 42.56 V at -20 C (14 max).

 8 kW Reference Array

### 19 Panels = 8,075 W STC

Occupies 37.0 m2 (399 sq ft) producing 7,585 W PTC; NEC 690.8 OCPD floor is 22.07 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.3 * (1 + (-0.247/100) * (-10 - 25)) = 41.61 V | OCPD = 1.56 * 14.15 = 22.07 A

Inputs from CEC Modules.csv for Regitec Solar BV RMHT54/425AB3: Voc=38.3 V, beta_Voc=-0.247%/C, Isc=14.15 A, STC=425.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (582.5 V); 19 panels for 8 kW (399 sq ft).

## What Are the Published CEC Specifications for Regitec Solar BV RMHT54/425AB3?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Regitec Solar BV RMHT54/425AB3.

Official California Energy Commission (NREL SAM) test parameters for Regitec Solar BV RMHT54/425AB3.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 425.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 399.2 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.15 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.7 V / 13.41 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.247 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.79% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Regitec Solar BV RMHT54/425AB3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Regitec Solar BV RMHT54/425AB3 (425.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.38 kW | 315 sq ft | $1,597 | $2,700 |
| **8 kW Class** | 19 | 8.07 kW | 399 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 24 | 10.2 kW | 504 sq ft | $2,553 | $4,317 |

## How Many Regitec Solar BV RMHT54/425AB3 Modules Fit in a Cold-Weather String?

Maximum series module counts for Regitec Solar BV RMHT54/425AB3 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.3V and beta_Voc=-0.247%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.56 V | 14 panels | 595.8 V | 23 panels |
| **-10 C (14 F)** | 41.61 V | 14 panels | 582.5 V | 24 panels |
| **0 C (32 F)** | 40.67 V | 14 panels | 569.4 V | 24 panels |
| **25 C (77 F STC)** | 38.3 V | 15 panels | 574.5 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMHT54/425AB3?

Alternative CEC solar modules from competing brands near Regitec Solar BV RMHT54/425AB3 (425.0 W), including Auxin Solar AXN10M420W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN10M420W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m420w/) Auxin Solar | 420.0 W | -5.0 W | 38.26 V | 21.65% | 93.2% |
| [**Aptos Solar Technology LLC DNA-108-MFN10-420W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-420w/) Aptos Solar Technology LLC | 420.0 W | -5.0 W | 38.5 V | 21.65% | 95.0% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-lv-n-420/) Elin Energy (Sirius PV) | 420.0 W | -5.0 W | 38.5 V | 21.65% | 94.9% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-N-420**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-n-420/) Elin Energy (Sirius PV) | 420.0 W | -5.0 W | 38.5 V | 21.65% | 94.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMHT54/425AB3?

Evaluate Regitec Solar BV RMHT54/425AB3 (425.0 W STC, 38.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMHT54/425AB3 reaches 42.56 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (399 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMHT54/425AB3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Regitec Solar BV RMHT54/425AB3 8 kW Residential Fit

Needs 19 modules (399 sq ft) with a 25 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M420W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 399.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Regitec Solar BV RMHT54/425AB3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Regitec Solar BV RMHT54/425AB3 PTC wattage (399.2 W) lower than STC (425.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 399.2 W PTC (93.9% retention) across Regitec Solar BV RMHT54/425AB3's 1.95 m2 aperture.

### Who should skip Regitec Solar BV RMHT54/425AB3 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Regitec Solar BV RMHT54/425AB3 panels (399 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M420W.

### What is the 1,000 V commercial string limit for Regitec Solar BV RMHT54/425AB3?

On 1,000 V commercial inverters at -10 C (41.61 V cold Voc), Regitec Solar BV RMHT54/425AB3 fits up to 24 panels per series string.

## Related Pages

Compare Regitec Solar BV equipment, Auxin Solar AXN10M420W specs, utility payback rates, and NEC string calculators alongside Regitec Solar BV RMHT54/425AB3.

[All Regitec Solar BV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Regitec Solar BV

- [All Regitec Solar BV Specs](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/)
- [Regitec Solar BV RMHT72/565S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s1/)
- [Regitec Solar BV RMHT72/565S3](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s3/)
- [Regitec Solar BV RMHT72/575S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-575s2/)
- [Regitec Solar BV RMHT72/570S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s1/)
- [Regitec Solar BV RMHT72/570S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s2/)