title: "Regitec Solar BV RMH72/545S2 Specs (545.0W, 50.04V Voc)"
url: https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmh72-545s2/
description: "CEC datasheet for Regitec Solar BV RMH72/545S2: 545.0W STC, 50.04V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Regitec Solar BV RMH72/545S2 — CEC Solar Module Specifications

Manufacturer: [**Regitec Solar BV**](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) Registry: **CEC Verified Engineering Specification**

Regitec Solar BV RMH72/545S2 is a 545.0 W STC (513.6 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.12% efficiency, 50.04 V Voc at 25 C, and 54.44 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 545.0 W

- **PTC Wattage** : 513.6 W

- **Voc @ 25C** : 50.04 V

- **Efficiency** : 21.12%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Regitec Solar BV RMH72/545S2 Compare Against Peer CEC Listings?

Solar engineering breakdown for Regitec Solar BV RMH72/545S2: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 545.0 W STC and 513.6 W PTC, Regitec Solar BV RMH72/545S2 sits +160.0 W vs all-CEC median (top 15.1%; higher than 84.9% of peers) among 21,677 listed modules. Power density reaches 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). Higher 50.04 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI rates 545.0 W.

## Where Does Regitec Solar BV RMH72/545S2 Fall Across Listed CEC Models?

Distribution marker showing Regitec Solar BV RMH72/545S2 (545.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Regitec Solar BV RMH72/545S2?

Dataset percentiles tracking Regitec Solar BV RMH72/545S2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Regitec Solar BV RMH72/545S2?

Benchmark highlights for Regitec Solar BV RMH72/545S2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #2,998 / 21,677

### Top 15.1% STC Output

545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,831

### 21.12% Aperture Efficiency

Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.44 V at -10 C (598.8 V string) and 55.69 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,175 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,704 W PTC; NEC 690.8 OCPD floor is 21.68 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.04 * (1 + (-0.251/100) * (-10 - 25)) = 54.44 V | OCPD = 1.56 * 13.9 = 21.68 A

Inputs from CEC Modules.csv for Regitec Solar BV RMH72/545S2: Voc=50.04 V, beta_Voc=-0.251%/C, Isc=13.9 A, STC=545.0 W, Area=2.58 m2.

**Result:** 11 panels max on 600 V (598.8 V); 15 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for Regitec Solar BV RMH72/545S2?

Official CEC datasheet figures for Regitec Solar BV RMH72/545S2 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Regitec Solar BV RMH72/545S2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 545.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 513.6 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.04 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.33 V / 13.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.251 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.12% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Regitec Solar BV RMH72/545S2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Regitec Solar BV RMH72/545S2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.54 kW | 333 sq ft | $1,637 | $2,768 |
| **8 kW Class** | 15 | 8.18 kW | 417 sq ft | $2,047 | $3,462 |
| **10 kW Class** | 19 | 10.36 kW | 528 sq ft | $2,593 | $4,385 |

## How Many Regitec Solar BV RMH72/545S2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Regitec Solar BV RMH72/545S2 (54.44 V at 14 F).

Computed from Voc=50.04V and beta_Voc=-0.251%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.69 V | 10 panels | 556.9 V | 17 panels |
| **-10 C (14 F)** | 54.44 V | 11 panels | 598.8 V | 18 panels |
| **0 C (32 F)** | 53.18 V | 11 panels | 585.0 V | 18 panels |
| **25 C (77 F STC)** | 50.04 V | 11 panels | 550.4 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH72/545S2?

Competing CEC solar panels closest to Regitec Solar BV RMH72/545S2 in nameplate wattage and Voc, starting with HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI**](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/) HYUNDAI ENERGY SOLUTIONS CO LTD | 545.0 W | Tie (0 W) | 50.0 V | 21.21% | 94.0% |
| [**Exiom Solution S A EX545-144BMH-DG**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex545-144bmh-dg/) Exiom Solution S A | 545.0 W | Tie (0 W) | 49.8 V | 21.12% | 93.4% |
| [**Exiom Solution S A EX545-144M-BMH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex545-144m-bmh/) Exiom Solution S A | 545.0 W | Tie (0 W) | 49.8 V | 21.12% | 93.7% |
| [**Bluesun Solar CoLtd BSM545M10-72HBD**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm545m10-72hbd/) Bluesun Solar CoLtd | 545.0 W | Tie (0 W) | 49.76 V | 21.03% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH72/545S2?

Evaluate Regitec Solar BV RMH72/545S2 (545.0 W STC, 50.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH72/545S2 reaches 55.69 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH72/545S2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Regitec Solar BV RMH72/545S2 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 513.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Regitec Solar BV RMH72/545S2 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Regitec Solar BV RMH72/545S2 panels fit on a 600 V winter solar string?

At -10 C (14 F), Regitec Solar BV RMH72/545S2 cold Voc rises from 50.04 V to 54.44 V (beta_Voc -0.251%/C), capping a 600 V string at 11 panels (598.8 V).

### How much roof area does an 8 kW array of Regitec Solar BV RMH72/545S2 need?

An 8 kW DC system uses 15 Regitec Solar BV RMH72/545S2 modules (8,175 W STC / 7,704 W PTC), covering roughly 417 sq ft and saving ~$2,047/yr at 18.54 c/kWh.

### How does Regitec Solar BV RMH72/545S2 compare against HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI?

Regitec Solar BV RMH72/545S2 outputs 545.0 W STC (50.04 V Voc, rank #2,998 of 21,677), while HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI delivers 545.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Regitec Solar BV equipment, HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI specs, utility payback rates, and NEC string calculators alongside Regitec Solar BV RMH72/545S2.

[All Regitec Solar BV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Regitec Solar BV

- [All Regitec Solar BV Specs](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/)
- [Regitec Solar BV RMHT72/565S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s1/)
- [Regitec Solar BV RMHT72/565S3](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s3/)
- [Regitec Solar BV RMHT72/575S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-575s2/)
- [Regitec Solar BV RMHT72/570S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s1/)
- [Regitec Solar BV RMHT72/570S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s2/)