Regitec Solar BV RMH54/410AB2 is a 410.0 W STC (386.3 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 38.2 V Voc at 25 C, and 41.56 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 386.3 W

- **Voc @ 25C** : 38.2 V

- **Efficiency** : 21.03%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Regitec Solar BV RMH54/410AB2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Regitec Solar BV RMH54/410AB2 (Mono-c-Si) residential solar systems.

Homeowners evaluating Regitec Solar BV RMH54/410AB2 need 15 panels for 6 kW or 20 panels (420 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.251%/C) pushes open-circuit voltage to 41.56 V at 14 F and 42.51 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does Regitec Solar BV RMH54/410AB2 Fall Across Listed CEC Models?

Comparison of Regitec Solar BV RMH54/410AB2 (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Regitec Solar BV RMH54/410AB2?

Relative ranking of Regitec Solar BV RMH54/410AB2 across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Regitec Solar BV RMH54/410AB2?

Summary of Regitec Solar BV RMH54/410AB2 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

### 21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.56 V at -10 C (581.8 V string) and 42.51 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,726 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.2 * (1 + (-0.251/100) * (-10 - 25)) = 41.56 V | OCPD = 1.56 * 13.93 = 21.73 A

Inputs from CEC Modules.csv for Regitec Solar BV RMH54/410AB2: Voc=38.2 V, beta_Voc=-0.251%/C, Isc=13.93 A, STC=410.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (581.8 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for Regitec Solar BV RMH54/410AB2?

Complete CEC test sheet for Regitec Solar BV RMH54/410AB2 including Isc (13.93 A), Voc (38.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Regitec Solar BV RMH54/410AB2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 386.3 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.6 V / 12.98 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.251 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.03% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Regitec Solar BV RMH54/410AB2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Regitec Solar BV RMH54/410AB2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |

## How Many Regitec Solar BV RMH54/410AB2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Regitec Solar BV RMH54/410AB2 (38.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.2V and beta_Voc=-0.251%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.51 V | 14 panels | 595.1 V | 23 panels |
| **-10 C (14 F)** | 41.56 V | 14 panels | 581.8 V | 24 panels |
| **0 C (32 F)** | 40.6 V | 14 panels | 568.4 V | 24 panels |
| **25 C (77 F STC)** | 38.2 V | 15 panels | 573.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH54/410AB2?

Four comparable CEC modules such as CSI Solar Co Ltd CS6R-410MB (410.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6R-410MB**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-410mb/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
| [**CSI Solar Co Ltd CS6R-410MB-HL**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-410mb-hl/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
| [**ASTORIOS Holding Inc ASTR108BDG-410W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr108bdg-410w-us/) ASTORIOS Holding Inc | 410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| [**AXITEC AC-410MBT/108US**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mbt-108us/) AXITEC | 410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH54/410AB2?

Evaluate Regitec Solar BV RMH54/410AB2 (410.0 W STC, 38.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH54/410AB2 reaches 42.51 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH54/410AB2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Regitec Solar BV RMH54/410AB2 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6R-410MB.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 386.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Regitec Solar BV RMH54/410AB2 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Regitec Solar BV RMH54/410AB2 PTC wattage (386.3 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 386.3 W PTC (94.2% retention) across Regitec Solar BV RMH54/410AB2's 1.95 m2 aperture.

### Who should skip Regitec Solar BV RMH54/410AB2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Regitec Solar BV RMH54/410AB2 panels (420 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6R-410MB.

### What is the 1,000 V commercial string limit for Regitec Solar BV RMH54/410AB2?

On 1,000 V commercial inverters at -10 C (41.56 V cold Voc), Regitec Solar BV RMH54/410AB2 fits up to 24 panels per series string.

## Related Pages

Compare Regitec Solar BV equipment, CSI Solar Co Ltd CS6R-410MB specs, utility payback rates, and NEC string calculators alongside Regitec Solar BV RMH54/410AB2.

[All Regitec Solar BV Certified Solar Models](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Regitec Solar BV

- [All Regitec Solar BV Specs](https://epri-peac.com/solar-equipment/brands/regitec-solar-bv/)
- [Regitec Solar BV RMHT72/565S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s1/)
- [Regitec Solar BV RMHT72/565S3](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-565s3/)
- [Regitec Solar BV RMHT72/575S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-575s2/)
- [Regitec Solar BV RMHT72/570S1](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s1/)
- [Regitec Solar BV RMHT72/570S2](https://epri-peac.com/solar-equipment/modules/regitec-solar-bv/regitec-solar-bv-rmht72-570s2/)