title: "ReCreate DS-MERCURY-485TC Specs (485.0W, 42.85V Voc)"
url: https://epri-peac.com/solar-equipment/modules/recreate/recreate-ds-mercury-485tc/
description: "CEC datasheet for ReCreate DS-MERCURY-485TC: 485.0W STC, 42.85V Voc, 17-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# ReCreate DS-MERCURY-485TC — CEC Solar Module Specifications

Manufacturer: [**ReCreate**](https://epri-peac.com/solar-equipment/brands/recreate/) Registry: **CEC Verified Engineering Specification**

ReCreate DS-MERCURY-485TC is a 485.0 W STC (456.6 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 23.1% efficiency, 42.85 V Voc at 25 C, and 46.28 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 485.0 W

- **PTC Wattage** : 456.6 W

- **Voc @ 25C** : 42.85 V

- **Efficiency** : 23.1%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does ReCreate DS-MERCURY-485TC Compare Against Peer CEC Listings?

Engineering position of ReCreate DS-MERCURY-485TC (485.0 W STC) vs. Hanersun Energy Co Ltd HN18N-60HT485W across 5,889 CEC Mono-c-Si solar modules.

Ranking #4,730 across 21,677 CEC solar panels (top 22.2%; higher than 77.8% of peers), ReCreate DS-MERCURY-485TC operates as a modern high-density residential and light-commercial module sitting 75.0 W above the 410.0 W Mono-c-Si median. Mid-range 42.85 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), 17 panels occupy 384 sq ft and offset roughly $2,062/yr at average US rates (or $3,487/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does ReCreate DS-MERCURY-485TC Fall Across Listed CEC Models?

Plots ReCreate DS-MERCURY-485TC at 485.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define ReCreate DS-MERCURY-485TC?

Benchmarks ReCreate DS-MERCURY-485TC on STC wattage, thermal PTC/STC retention, and 23.1 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for ReCreate DS-MERCURY-485TC?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for ReCreate DS-MERCURY-485TC by ReCreate.

Rank #4,730 / 21,677

### Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #985

### 23.1% Aperture Efficiency

Power density 231.0 W/m2 (3.19 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.28 V at -10 C (555.4 V string) and 47.27 V at -20 C (12 max).

 8 kW Reference Array

### 17 Panels = 8,245 W STC

Occupies 35.7 m2 (384 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 22.46 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.85 * (1 + (-0.229/100) * (-10 - 25)) = 46.28 V | OCPD = 1.56 * 14.4 = 22.46 A

Inputs from CEC Modules.csv for ReCreate DS-MERCURY-485TC: Voc=42.85 V, beta_Voc=-0.229%/C, Isc=14.4 A, STC=485.0 W, Area=2.1 m2.

**Result:** 12 panels max on 600 V (555.4 V); 17 panels for 8 kW (384 sq ft).

## What Are the Published CEC Specifications for ReCreate DS-MERCURY-485TC?

Laboratory test ratings recorded for ReCreate DS-MERCURY-485TC (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for ReCreate DS-MERCURY-485TC.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 485.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 456.6 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 42.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.51 V / 13.66 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.229 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.1% (2.1 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many ReCreate DS-MERCURY-485TC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (384 sq ft at 8 kW), and estimated Year-1 electric bill offset for ReCreate DS-MERCURY-485TC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.3 kW | 294 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 17 | 8.24 kW | 384 sq ft | $2,062 | $3,487 |
| **10 kW Class** | 21 | 10.19 kW | 475 sq ft | $2,550 | $4,313 |

## Which Sibling Wattage & Trim Variants Belong to This ReCreate Series?

Sibling wattage bins and frame colors grouped with ReCreate DS-MERCURY-485TC under ReCreate to prevent duplicate spec pages. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the ReCreate DS-MERCURY-485TC wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **ReCreate DS-MERCURY-475TC** | 475.0 W | 446.9 W | 42.51 V | 35.19 V | 22.62% |
| **ReCreate DS-MERCURY-480TC** | 480.0 W | 451.8 W | 42.68 V | 35.35 V | 22.86% |
| **ReCreate DS-MERCURY-485TC** | 485.0 W | 456.6 W | 42.85 V | 35.51 V | 23.1% |

## How Many ReCreate DS-MERCURY-485TC Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for ReCreate DS-MERCURY-485TC (beta_Voc -0.229%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=42.85V and beta_Voc=-0.229%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 47.27 V | 12 panels | 567.2 V | 21 panels |
| **-10 C (14 F)** | 46.28 V | 12 panels | 555.4 V | 21 panels |
| **0 C (32 F)** | 45.3 V | 13 panels | 588.9 V | 22 panels |
| **25 C (77 F STC)** | 42.85 V | 14 panels | 599.9 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to ReCreate DS-MERCURY-485TC?

Closest cross-brand CEC competitors to ReCreate DS-MERCURY-485TC matched near 485.0 W STC and 42.85 V Voc, led by Hanersun Energy Co Ltd HN18N-60HT485W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanersun Energy Co Ltd HN18N-60HT485W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18n-60ht485w/) Hanersun Energy Co Ltd | 485.0 W | Tie (0 W) | 43.0 V | 22.99% | 94.9% |
| [**CSI Solar Co Ltd CS61-60TM-485H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-60tm-485h/) CSI Solar Co Ltd | 485.0 W | Tie (0 W) | 42.6 V | 22.15% | 94.7% |
| [**Auxin Solar AXN10M485B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485b/) Auxin Solar | 485.0 W | Tie (0 W) | 43.98 V | 22.56% | 92.0% |
| [**Auxin Solar AXN10M485W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485w/) Auxin Solar | 485.0 W | Tie (0 W) | 43.98 V | 22.56% | 91.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for ReCreate DS-MERCURY-485TC?

Evaluate ReCreate DS-MERCURY-485TC (485.0 W STC, 42.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), ReCreate DS-MERCURY-485TC reaches 47.27 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 384 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (384 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of ReCreate DS-MERCURY-485TC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### ReCreate DS-MERCURY-485TC 8 kW Residential Fit

Needs 17 modules (384 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hanersun Energy Co Ltd HN18N-60HT485W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 456.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ReCreate DS-MERCURY-485TC by ReCreate grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

### How many ReCreate DS-MERCURY-485TC panels fit on a 600 V winter solar string?

At -10 C (14 F), ReCreate DS-MERCURY-485TC cold Voc rises from 42.85 V to 46.28 V (beta_Voc -0.229%/C), capping a 600 V string at 12 panels (555.4 V).

### How much roof area does an 8 kW array of ReCreate DS-MERCURY-485TC need?

An 8 kW DC system uses 17 ReCreate DS-MERCURY-485TC modules (8,245 W STC / 7,762 W PTC), covering roughly 384 sq ft and saving ~$2,062/yr at 18.54 c/kWh.

### How does ReCreate DS-MERCURY-485TC compare against Hanersun Energy Co Ltd HN18N-60HT485W?

ReCreate DS-MERCURY-485TC outputs 485.0 W STC (42.85 V Voc, rank #4,730 of 21,677), while Hanersun Energy Co Ltd HN18N-60HT485W delivers 485.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare ReCreate equipment, Hanersun Energy Co Ltd HN18N-60HT485W specs, utility payback rates, and NEC string calculators alongside ReCreate DS-MERCURY-485TC.

[All ReCreate Certified Solar Models](https://epri-peac.com/solar-equipment/brands/recreate/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From ReCreate

- [All ReCreate Specs](https://epri-peac.com/solar-equipment/brands/recreate/)
- [ReCreate DS-MERCURY-470TC](https://epri-peac.com/solar-equipment/modules/recreate/recreate-ds-mercury-470tc/)