title: "Recom RCM-345-6MA Specs (345.0W, 47.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-345-6ma/
description: "CEC datasheet for Recom RCM-345-6MA: 345.0W STC, 47.9V Voc, 24-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Recom RCM-345-6MA — CEC Solar Module Specifications

Manufacturer: [**Recom**](https://epri-peac.com/solar-equipment/brands/recom/) Registry: **CEC Verified Engineering Specification**

Recom RCM-345-6MA is a 345.0 W STC (313.5 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.78% efficiency, 47.9 V Voc at 25 C, and 53.1 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 345.0 W

- **PTC Wattage** : 313.5 W

- **Voc @ 25C** : 47.9 V

- **Efficiency** : 17.78%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Recom RCM-345-6MA Compare Against Peer CEC Listings?

Solar engineering breakdown for Recom RCM-345-6MA: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Across 5,889 Mono-c-Si listings from Recom and peers, Recom RCM-345-6MA stands 65.0 W below the 410.0 W Mono-c-Si median and typical 90.9% PTC-to-STC thermal output (313.5 W real-world rating). Sizing 6 kW (18 panels) to 10 kW (29 panels) yields $1,554-$2,505/yr in baseline US bill offset. Mid-range 47.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does Recom RCM-345-6MA Fall Across Listed CEC Models?

Distribution marker showing Recom RCM-345-6MA (345.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Dataset Percentiles Define Recom RCM-345-6MA?

Dataset percentiles tracking Recom RCM-345-6MA power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for Recom RCM-345-6MA?

Benchmark highlights for Recom RCM-345-6MA covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #13,309 / 21,677

### 345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,390

### 17.78% Aperture Efficiency

Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.1 V at -10 C (584.1 V string) and 54.58 V at -20 C (10 max).

 8 kW Reference Array

### 24 Panels = 8,280 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 14.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.9 * (1 + (-0.31/100) * (-10 - 25)) = 53.1 V | OCPD = 1.56 * 9.05 = 14.12 A

Inputs from CEC Modules.csv for Recom RCM-345-6MA: Voc=47.9 V, beta_Voc=-0.31%/C, Isc=9.05 A, STC=345.0 W, Area=1.94 m2.

**Result:** 11 panels max on 600 V (584.1 V); 24 panels for 8 kW (501 sq ft).

## What Are the Published CEC Specifications for Recom RCM-345-6MA?

Official CEC datasheet figures for Recom RCM-345-6MA (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-345-6MA.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 313.5 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.9 V / 8.91 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.31 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.78% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Recom RCM-345-6MA Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Recom RCM-345-6MA modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 18 | 6.21 kW | 376 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 24 | 8.28 kW | 501 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 29 | 10.01 kW | 606 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Recom Series?

Consolidated Recom wattage variants sharing the Recom RCM-345-6MA mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Recom RCM-345-6MA wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Recom RCM-325-6MA** | 325.0 W | 294.8 W | 47.0 V | 38.4 V | 16.75% |
| **Recom RCM-330-6MA** | 330.0 W | 299.5 W | 47.1 V | 38.5 V | 17.01% |
| **Recom RCM-335-6MA** | 335.0 W | 304.1 W | 47.4 V | 38.7 V | 17.26% |
| **Recom RCM-340-6MA** | 340.0 W | 308.8 W | 47.6 V | 38.8 V | 17.52% |
| **Recom RCM-345-6MA** | 345.0 W | 313.5 W | 47.9 V | 38.9 V | 17.78% |

## How Many Recom RCM-345-6MA Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Recom RCM-345-6MA (53.1 V at 14 F). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Computed from Voc=47.9V and beta_Voc=-0.31%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.58 V | 10 panels | 545.8 V | 18 panels |
| **-10 C (14 F)** | 53.1 V | 11 panels | 584.1 V | 18 panels |
| **0 C (32 F)** | 51.61 V | 11 panels | 567.7 V | 19 panels |
| **25 C (77 F STC)** | 47.9 V | 12 panels | 574.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Recom RCM-345-6MA?

Competing CEC solar panels closest to Recom RCM-345-6MA in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/72345.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-P6/72345**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-72345/) GCL System Integration Technology Co Ltd | 345.0 W | Tie (0 W) | 47.3 V | 17.78% | 91.6% |
| [**AXITEC AC-345M/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-345m-156-72s/) AXITEC | 345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| [**GCL System Integration Technology Co Ltd GCL-P3/72H345**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p3-72h345/) GCL System Integration Technology Co Ltd | 345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| [**GCL System Integration Technology Co Ltd GCL-M6/72345**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-72345/) GCL System Integration Technology Co Ltd | 345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Recom RCM-345-6MA?

Evaluate Recom RCM-345-6MA (345.0 W STC, 47.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-345-6MA reaches 54.58 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
- 2026 tax credit baseline: cash residential installs of Recom RCM-345-6MA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Recom RCM-345-6MA 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72345.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 313.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-345-6MA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

### What fuse or breaker size does NEC 690.8 require for Recom RCM-345-6MA?

Multiplying Recom RCM-345-6MA's 9.05 A short-circuit current by 1.56 equals 14.12 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-345-6MA before finalizing component orders.

### Can Recom RCM-345-6MA pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.1 V cold Voc at 14 F and handles 9.05 A Isc; string inverters cap Recom RCM-345-6MA at 11 panels on 600 V.

### Is Recom RCM-345-6MA eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-345-6MA rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

## Related Pages

Compare Recom equipment, GCL System Integration Technology Co Ltd GCL-P6/72345 specs, utility payback rates, and NEC string calculators alongside Recom RCM-345-6MA.

[All Recom Certified Solar Models](https://epri-peac.com/solar-equipment/brands/recom/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Recom

- [All Recom Specs](https://epri-peac.com/solar-equipment/brands/recom/)
- [Recom RCM-330-6PA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-330-6pa/)
- [Recom RCM-320-6MA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-320-6ma/)
- [Recom RCM-300-6PA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-300-6pa/)
- [Recom RCM-290-6PA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-290-6pa/)
- [Recom RCM-280-6MB-BB](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-280-6mb-bb/)