title: "Recom RCM-300-6PA Specs (300.0W, 44.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-300-6pa/
description: "CEC datasheet for Recom RCM-300-6PA: 300.0W STC, 44.8V Voc, 27-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Recom RCM-300-6PA — CEC Solar Module Specifications

Manufacturer: [**Recom**](https://epri-peac.com/solar-equipment/brands/recom/) Registry: **CEC Verified Engineering Specification**

Recom RCM-300-6PA is a 300.0 W STC (270.8 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.46% efficiency, 44.8 V Voc at 25 C, and 49.66 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 270.8 W

- **Voc @ 25C** : 44.8 V

- **Efficiency** : 15.46%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Recom RCM-300-6PA Compare Against Peer CEC Listings?

How Recom Recom RCM-300-6PA handles rooftop heat (270.8 W PTC), 8 kW sizing, and cold winter string voltage.

Recom builds the Recom RCM-300-6PA (Multi-c-Si) as a compact residential or specialty off-grid module delivering 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6P612T305G (305.0 W), this model holds typical 90.3% PTC-to-STC thermal output (270.8 W real-world rating). Mid-range 44.8 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.56 A overcurrent floor served by a 15 A breaker.

## Where Does Recom RCM-300-6PA Fall Across Listed CEC Models?

Where Recom RCM-300-6PA (300.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Recom RCM-300-6PA?

Percentile placement of Recom RCM-300-6PA across power density (154.6 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Do the Dataset Ranks Show for Recom RCM-300-6PA?

Four critical engineering numbers homeowners and solar installers check first when reviewing Recom RCM-300-6PA specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,977

### 15.46% Aperture Efficiency

Power density 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.66 V at -10 C (595.9 V string) and 51.05 V at -20 C (11 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 52.4 m2 (564 sq ft) producing 7,312 W PTC; NEC 690.8 OCPD floor is 13.56 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.31/100) * (-10 - 25)) = 49.66 V | OCPD = 1.56 * 8.69 = 13.56 A

Inputs from CEC Modules.csv for Recom RCM-300-6PA: Voc=44.8 V, beta_Voc=-0.31%/C, Isc=8.69 A, STC=300.0 W, Area=1.94 m2.

**Result:** 12 panels max on 600 V (595.9 V); 27 panels for 8 kW (564 sq ft).

## What Are the Published CEC Specifications for Recom RCM-300-6PA?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Recom RCM-300-6PA. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-300-6PA.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 270.8 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.6 V / 8.2 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.31 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.46% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Recom RCM-300-6PA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Recom RCM-300-6PA (300.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 418 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 564 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 710 sq ft | $2,553 | $4,317 |

## Which Sibling Wattage & Trim Variants Belong to This Recom Series?

All closely matched Recom wattages and cosmetic trims sharing the Recom RCM-300-6PA architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Recom RCM-300-6PA wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Recom RCM-300-6PA** | 300.0 W | 270.8 W | 44.8 V | 36.6 V | 15.46% |
| **Recom RCM-305-6PA** | 305.0 W | 275.4 W | 44.95 V | 36.82 V | 15.72% |
| **Recom RCM-310-6PA** | 310.0 W | 280.1 W | 45.0 V | 37.0 V | 15.98% |
| **Recom RCM-315-6PA** | 315.0 W | 286.6 W | 45.4 V | 37.8 V | 16.23% |
| **Recom RCM-320-6PA** | 320.0 W | 291.2 W | 45.94 V | 38.23 V | 16.49% |

## How Many Recom RCM-300-6PA Modules Fit in a Cold-Weather String?

Maximum series module counts for Recom RCM-300-6PA from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.8V and beta_Voc=-0.31%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.05 V | 11 panels | 561.5 V | 19 panels |
| **-10 C (14 F)** | 49.66 V | 12 panels | 595.9 V | 20 panels |
| **0 C (32 F)** | 48.27 V | 12 panels | 579.2 V | 20 panels |
| **25 C (77 F STC)** | 44.8 V | 13 panels | 582.4 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Recom RCM-300-6PA?

Alternative CEC solar modules from competing brands near Recom RCM-300-6PA (300.0 W), including Auxin Solar AXN6P612T305G. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN6P612T305G**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t305g/) Auxin Solar | 305.0 W | +5.0 W | 45.0 V | 15.63% | 90.3% |
| [**CSI Solar Co Ltd CS6X-310P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6x-310p/) CSI Solar Co Ltd | 310.0 W | +10.0 W | 44.9 V | 16.31% | 91.4% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM310-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm310-72/) Anhui Rinengzhongtian Semiconductor Development | 310.0 W | +10.0 W | 44.65 V | 15.98% | 90.0% |
| [**Anhui Rinengzhongtian Semiconductor Development QJP310-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp310-72/) Anhui Rinengzhongtian Semiconductor Development | 310.0 W | +10.0 W | 44.65 V | 15.98% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Recom RCM-300-6PA?

Evaluate Recom RCM-300-6PA (300.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-300-6PA reaches 51.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft).
- 2026 tax credit baseline: cash residential installs of Recom RCM-300-6PA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Recom RCM-300-6PA 8 kW Residential Fit

Needs 27 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-300-6PA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

### What fuse or breaker size does NEC 690.8 require for Recom RCM-300-6PA?

Multiplying Recom RCM-300-6PA's 8.69 A short-circuit current by 1.56 equals 13.56 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-300-6PA before finalizing component orders.

### Can Recom RCM-300-6PA pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.66 V cold Voc at 14 F and handles 8.69 A Isc; string inverters cap Recom RCM-300-6PA at 12 panels on 600 V.

### Is Recom RCM-300-6PA eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-300-6PA rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare Recom equipment, Auxin Solar AXN6P612T305G specs, utility payback rates, and NEC string calculators alongside Recom RCM-300-6PA. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

[All Recom Certified Solar Models](https://epri-peac.com/solar-equipment/brands/recom/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Recom

- [All Recom Specs](https://epri-peac.com/solar-equipment/brands/recom/)
- [Recom RCM-345-6MA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-345-6ma/)
- [Recom RCM-330-6PA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-330-6pa/)
- [Recom RCM-320-6MA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-320-6ma/)
- [Recom RCM-290-6PA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-290-6pa/)
- [Recom RCM-280-6MB-BB](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-280-6mb-bb/)