# Recom RCM-290-6PA — CEC Solar Module Specifications

Manufacturer: [**Recom**](https://epri-peac.com/solar-equipment/brands/recom/) Registry: **CEC Verified Engineering Specification**

Recom RCM-290-6PA is a 290.0 W STC (261.5 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.95% efficiency, 44.8 V Voc at 25 C, and 49.66 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 290.0 W

- **PTC Wattage** : 261.5 W

- **Voc @ 25C** : 44.8 V

- **Efficiency** : 14.95%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Recom RCM-290-6PA Compare Against Peer CEC Listings?

How Recom Recom RCM-290-6PA handles rooftop heat (261.5 W PTC), 8 kW sizing, and cold winter string voltage.

Recom builds the Recom RCM-290-6PA (Multi-c-Si) as a compact residential or specialty off-grid module delivering 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). Compared against Gintung Energy GTEC-290G6S (290.0 W), this model holds typical 90.2% PTC-to-STC thermal output (261.5 W real-world rating). Mid-range 44.8 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.35 A overcurrent floor served by a 15 A breaker.

## Where Does Recom RCM-290-6PA Fall Across Listed CEC Models?

Where Recom RCM-290-6PA (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Recom RCM-290-6PA?

Percentile placement of Recom RCM-290-6PA across power density (149.5 W/m2), thermal retention, and nameplate STC wattage. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Do the Dataset Ranks Show for Recom RCM-290-6PA?

Four critical engineering numbers homeowners and solar installers check first when reviewing Recom RCM-290-6PA specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #17,253 / 21,677

### 290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,805

### 14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.66 V at -10 C (595.9 V string) and 51.05 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,120 W STC

Occupies 54.3 m2 (585 sq ft) producing 7,322 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.31/100) * (-10 - 25)) = 49.66 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for Recom RCM-290-6PA: Voc=44.8 V, beta_Voc=-0.31%/C, Isc=8.56 A, STC=290.0 W, Area=1.94 m2.

**Result:** 12 panels max on 600 V (595.9 V); 28 panels for 8 kW (585 sq ft).

## What Are the Published CEC Specifications for Recom RCM-290-6PA?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Recom RCM-290-6PA. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-290-6PA.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 261.5 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.3 V / 8.0 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.31 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.95% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Recom RCM-290-6PA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Recom RCM-290-6PA (290.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.09 kW | 439 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 28 | 8.12 kW | 585 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 35 | 10.15 kW | 731 sq ft | $2,540 | $4,296 |

## Which Sibling Wattage & Trim Variants Belong to This Recom Series?

All closely matched Recom wattages and cosmetic trims sharing the Recom RCM-290-6PA architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Recom RCM-290-6PA wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Recom RCM-285-6PA** | 285.0 W | 256.9 W | 44.7 V | 36.2 V | 14.69% |
| **Recom RCM-290-6PA** | 290.0 W | 261.5 W | 44.8 V | 36.3 V | 14.95% |
| **Recom RCM-295-6PA** | 295.0 W | 266.2 W | 44.9 V | 36.4 V | 15.2% |

## How Many Recom RCM-290-6PA Modules Fit in a Cold-Weather String?

Maximum series module counts for Recom RCM-290-6PA from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.8V and beta_Voc=-0.31%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.05 V | 11 panels | 561.5 V | 19 panels |
| **-10 C (14 F)** | 49.66 V | 12 panels | 595.9 V | 20 panels |
| **0 C (32 F)** | 48.27 V | 12 panels | 579.2 V | 20 panels |
| **25 C (77 F STC)** | 44.8 V | 13 panels | 582.4 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Recom RCM-290-6PA?

Alternative CEC solar modules from competing brands near Recom RCM-290-6PA (290.0 W), including Gintung Energy GTEC-290G6S. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy GTEC-290G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6s/) Gintung Energy | 290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| [**AXITEC AC-290M/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-290m-156-72s/) AXITEC | 290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| [**Gintung Energy GTEC-290G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6m/) Gintung Energy | 290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| [**Centrosolar America DM72 290**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-290/) Centrosolar America | 290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Recom RCM-290-6PA?

Evaluate Recom RCM-290-6PA (290.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-290-6PA reaches 51.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
- 2026 tax credit baseline: cash residential installs of Recom RCM-290-6PA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Recom RCM-290-6PA 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy GTEC-290G6S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 261.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-290-6PA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

### What fuse or breaker size does NEC 690.8 require for Recom RCM-290-6PA?

Multiplying Recom RCM-290-6PA's 8.56 A short-circuit current by 1.56 equals 13.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-290-6PA before finalizing component orders.

### Can Recom RCM-290-6PA pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.66 V cold Voc at 14 F and handles 8.56 A Isc; string inverters cap Recom RCM-290-6PA at 12 panels on 600 V.

### Is Recom RCM-290-6PA eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-290-6PA rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

## Related Pages

Compare Recom equipment, Gintung Energy GTEC-290G6S specs, utility payback rates, and NEC string calculators alongside Recom RCM-290-6PA. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

[All Recom Certified Solar Models](https://epri-peac.com/solar-equipment/brands/recom/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Recom

- [All Recom Specs](https://epri-peac.com/solar-equipment/brands/recom/)
- [Recom RCM-345-6MA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-345-6ma/)
- [Recom RCM-330-6PA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-330-6pa/)
- [Recom RCM-320-6MA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-320-6ma/)
- [Recom RCM-300-6PA](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-300-6pa/)
- [Recom RCM-280-6MB-BB](https://epri-peac.com/solar-equipment/modules/recom/recom-rcm-280-6mb-bb/)