title: "RECOM SILLIA RCM-285-6PB Specs (285.0W, 43.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/recom-sillia/recom-sillia-rcm-285-6pb/
description: "CEC datasheet for RECOM SILLIA RCM-285-6PB: 285.0W STC, 43.0V Voc, 29-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# RECOM SILLIA RCM-285-6PB — CEC Solar Module Specifications

Manufacturer: [**RECOM SILLIA**](https://epri-peac.com/solar-equipment/brands/recom-sillia/) Registry: **CEC Verified Engineering Specification**

RECOM SILLIA RCM-285-6PB is a 285.0 W STC (251.1 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.59% efficiency, 43.0 V Voc at 25 C, and 48.4 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 285.0 W

- **PTC Wattage** : 251.1 W

- **Voc @ 25C** : 43.0 V

- **Efficiency** : 17.59%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does RECOM SILLIA RCM-285-6PB Compare Against Peer CEC Listings?

How RECOM SILLIA RECOM SILLIA RCM-285-6PB handles rooftop heat (251.1 W PTC), 8 kW sizing, and cold winter string voltage.

RECOM SILLIA builds the RECOM SILLIA RCM-285-6PB (Multi-c-Si) as a compact residential or specialty off-grid module delivering 175.9 W/m2 (2.32 percentage points below 19.91% CEC median). Compared against Anhui Rinengzhongtian Semiconductor Development QJP285-72 (285.0 W), this model holds typical 88.1% PTC-to-STC thermal output (251.1 W real-world rating). Mid-range 43.0 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.77 A overcurrent floor served by a 15 A breaker.

## Where Does RECOM SILLIA RCM-285-6PB Fall Across Listed CEC Models?

Where RECOM SILLIA RCM-285-6PB (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define RECOM SILLIA RCM-285-6PB?

Percentile placement of RECOM SILLIA RCM-285-6PB across power density (175.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for RECOM SILLIA RCM-285-6PB?

Four critical engineering numbers homeowners and solar installers check first when reviewing RECOM SILLIA RCM-285-6PB specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #17,598 / 21,677

### 285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,646

### 17.59% Aperture Efficiency

Power density 175.9 W/m2 (2.32 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.4 V at -10 C (580.8 V string) and 49.95 V at -20 C (12 max).

 8 kW Reference Array

### 29 Panels = 8,265 W STC

Occupies 47.0 m2 (506 sq ft) producing 7,282 W PTC; NEC 690.8 OCPD floor is 13.77 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.0 * (1 + (-0.359/100) * (-10 - 25)) = 48.4 V | OCPD = 1.56 * 8.83 = 13.77 A

Inputs from CEC Modules.csv for RECOM SILLIA RCM-285-6PB: Voc=43.0 V, beta_Voc=-0.359%/C, Isc=8.83 A, STC=285.0 W, Area=1.62 m2.

**Result:** 12 panels max on 600 V (580.8 V); 29 panels for 8 kW (506 sq ft).

## What Are the Published CEC Specifications for RECOM SILLIA RCM-285-6PB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for RECOM SILLIA RCM-285-6PB.

Official California Energy Commission (NREL SAM) test parameters for RECOM SILLIA RCM-285-6PB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 251.1 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.0 V / 8.14 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.359 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.59% (1.62 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many RECOM SILLIA RCM-285-6PB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using RECOM SILLIA RCM-285-6PB (285.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 22 | 6.27 kW | 384 sq ft | $1,569 | $2,654 |
| **8 kW Class** | 29 | 8.27 kW | 506 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 36 | 10.26 kW | 628 sq ft | $2,568 | $4,342 |

## Which Sibling Wattage & Trim Variants Belong to This RECOM SILLIA Series?

All closely matched RECOM SILLIA wattages and cosmetic trims sharing the RECOM SILLIA RCM-285-6PB architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the RECOM SILLIA RCM-285-6PB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **RECOM SILLIA RCM-275-6PB** | 275.0 W | 249.5 W | 38.15 V | 31.8 V | 16.98% |
| **RECOM SILLIA RCM-280-6PB** | 280.0 W | 254.2 W | 38.3 V | 32.0 V | 17.28% |
| **RECOM SILLIA RCM-285-6PB** | 285.0 W | 251.1 W | 43.0 V | 35.0 V | 17.59% |
| **RECOM SILLIA RCM-290-6PB** | 290.0 W | 255.7 W | 43.0 V | 35.0 V | 17.9% |

## How Many RECOM SILLIA RCM-285-6PB Modules Fit in a Cold-Weather String?

Maximum series module counts for RECOM SILLIA RCM-285-6PB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.0V and beta_Voc=-0.359%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 49.95 V | 12 panels | 599.4 V | 20 panels |
| **-10 C (14 F)** | 48.4 V | 12 panels | 580.8 V | 20 panels |
| **0 C (32 F)** | 46.86 V | 12 panels | 562.3 V | 21 panels |
| **25 C (77 F STC)** | 43.0 V | 13 panels | 559.0 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to RECOM SILLIA RCM-285-6PB?

Alternative CEC solar modules from competing brands near RECOM SILLIA RCM-285-6PB (285.0 W), including Anhui Rinengzhongtian Semiconductor Development QJP285-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJP285-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp285-72/) Anhui Rinengzhongtian Semiconductor Development | 285.0 W | Tie (0 W) | 43.1 V | 14.69% | 89.3% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM285-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm285-72/) Anhui Rinengzhongtian Semiconductor Development | 285.0 W | Tie (0 W) | 44.03 V | 14.69% | 89.8% |
| [**Advance Power API-M285**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m285/) Advance Power | 285.0 W | Tie (0 W) | 44.21 V | 14.61% | 89.1% |
| [**Advance Power API-P285**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p285/) Advance Power | 285.0 W | Tie (0 W) | 44.21 V | 14.61% | 90.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for RECOM SILLIA RCM-285-6PB?

Evaluate RECOM SILLIA RCM-285-6PB (285.0 W STC, 43.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), RECOM SILLIA RCM-285-6PB reaches 49.95 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 506 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (506 sq ft).
- 2026 tax credit baseline: cash residential installs of RECOM SILLIA RCM-285-6PB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### RECOM SILLIA RCM-285-6PB 8 kW Residential Fit

Needs 29 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP285-72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 251.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for RECOM SILLIA RCM-285-6PB by RECOM SILLIA grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for RECOM SILLIA RCM-285-6PB?

Multiplying RECOM SILLIA RCM-285-6PB's 8.83 A short-circuit current by 1.56 equals 13.77 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can RECOM SILLIA RCM-285-6PB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 48.4 V cold Voc at 14 F and handles 8.83 A Isc; string inverters cap RECOM SILLIA RCM-285-6PB at 12 panels on 600 V.

### Is RECOM SILLIA RCM-285-6PB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of RECOM SILLIA RCM-285-6PB rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

## Related Pages

Compare RECOM SILLIA equipment, Anhui Rinengzhongtian Semiconductor Development QJP285-72 specs, utility payback rates, and NEC string calculators alongside RECOM SILLIA RCM-285-6PB.

[All RECOM SILLIA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/recom-sillia/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From RECOM SILLIA

- [All RECOM SILLIA Specs](https://epri-peac.com/solar-equipment/brands/recom-sillia/)
- [RECOM SILLIA RCM-385-6MA](https://epri-peac.com/solar-equipment/modules/recom-sillia/recom-sillia-rcm-385-6ma/)
- [RECOM SILLIA RCM-360-6MA](https://epri-peac.com/solar-equipment/modules/recom-sillia/recom-sillia-rcm-360-6ma/)
- [RECOM SILLIA RCM-350-6PA](https://epri-peac.com/solar-equipment/modules/recom-sillia/recom-sillia-rcm-350-6pa/)
- [RECOM SILLIA RCM-330-6PA](https://epri-peac.com/solar-equipment/modules/recom-sillia/recom-sillia-rcm-330-6pa/)
- [RECOM SILLIA RCM-320-6PA](https://epri-peac.com/solar-equipment/modules/recom-sillia/recom-sillia-rcm-320-6pa/)