# REC Group REC740AA Pro XL — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC740AA Pro XL is a 740.0 W STC (706.4 W PTC) Mono-c-Si solar module ranking #5 of 21,677 CEC listings (top 0.1%; higher than 99.9% of peers). It delivers 22.22% efficiency, 53.8 V Voc at 25 C, and 58.04 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 740.0 W

- **PTC Wattage** : 706.4 W

- **Voc @ 25C** : 53.8 V

- **Efficiency** : 22.22%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC740AA Pro XL Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC740AA Pro XL: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC740AA Pro XL stands 330.0 W above the 410.0 W Mono-c-Si median and strong 95.5% PTC-to-STC heat retention (#102 of 21,677). Sizing 6 kW (9 panels) to 10 kW (14 panels) yields $1,667-$2,593/yr in baseline US bill offset. Higher 53.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does REC Group REC740AA Pro XL Fall Across Listed CEC Models?

Distribution marker showing REC Group REC740AA Pro XL (740.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define REC Group REC740AA Pro XL?

Dataset percentiles tracking REC Group REC740AA Pro XL power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for REC Group REC740AA Pro XL?

Benchmark highlights for REC Group REC740AA Pro XL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5 / 21,677

### Top 0.1% STC Output

740.0 W STC (+355.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,585

### 22.22% Aperture Efficiency

Power density 222.2 W/m2 (2.31 percentage points above 19.91% CEC median). PTC/STC ratio: 95.5% (rank #102).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.04 V at -10 C (580.4 V string) and 59.25 V at -20 C (10 max).

 8 kW Reference Array

### 11 Panels = 8,140 W STC

Occupies 36.6 m2 (394 sq ft) producing 7,770 W PTC; NEC 690.8 OCPD floor is 26.13 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.8 * (1 + (-0.225/100) * (-10 - 25)) = 58.04 V | OCPD = 1.56 * 16.75 = 26.13 A

Inputs from CEC Modules.csv for REC Group REC740AA Pro XL: Voc=53.8 V, beta_Voc=-0.225%/C, Isc=16.75 A, STC=740.0 W, Area=3.33 m2.

**Result:** 10 panels max on 600 V (580.4 V); 11 panels for 8 kW (394 sq ft).

## What Are the Published CEC Specifications for REC Group REC740AA Pro XL?

Official CEC datasheet figures for REC Group REC740AA Pro XL (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC740AA Pro XL.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 740.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 706.4 W (95.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 16.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.3 V / 15.97 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.225 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.22% (3.33 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many REC Group REC740AA Pro XL Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC740AA Pro XL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 9 | 6.66 kW | 323 sq ft | $1,667 | $2,819 |
| **8 kW Class** | 11 | 8.14 kW | 394 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 14 | 10.36 kW | 502 sq ft | $2,593 | $4,385 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Consolidated REC Group wattage variants sharing the REC Group REC740AA Pro XL mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the REC Group REC740AA Pro XL wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC730AA Pro XL** | 730.0 W | 696.6 W | 53.7 V | 46.3 V | 21.92% |
| **REC Group REC740AA Pro XL** | 740.0 W | 706.4 W | 53.8 V | 46.3 V | 22.22% |

## How Many REC Group REC740AA Pro XL Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC740AA Pro XL (58.04 V at 14 F).

Computed from Voc=53.8V and beta_Voc=-0.225%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.25 V | 10 panels | 592.5 V | 16 panels |
| **-10 C (14 F)** | 58.04 V | 10 panels | 580.4 V | 17 panels |
| **0 C (32 F)** | 56.83 V | 10 panels | 568.3 V | 17 panels |
| **25 C (77 F STC)** | 53.8 V | 11 panels | 591.8 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC740AA Pro XL?

Competing CEC solar panels closest to REC Group REC740AA Pro XL in nameplate wattage and Voc, starting with Trina Solar TSM-740NEG21C20.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Trina Solar TSM-740NEG21C20**](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-740neg21c20/) Trina Solar | 740.0 W | Tie (0 W) | 50.3 V | 23.79% | 94.5% |
| [**SEG Solar Inc SEG-735-BHC-BG**](https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-735-bhc-bg/) SEG Solar Inc | 735.0 W | -5.0 W | 50.47 V | 24.26% | 95.4% |
| [**Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-735**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm66n-dg-f-bh-735/) Chint New Energy Technology Co Ltd | 735.0 W | -5.0 W | 49.77 V | 23.63% | 94.9% |
| [**SEG Solar Inc SEG-735-BTC-BG**](https://epri-peac.com/solar-equipment/modules/seg-solar-inc/seg-solar-inc-seg-735-btc-bg/) SEG Solar Inc | 735.0 W | -5.0 W | 49.75 V | 24.26% | 95.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC740AA Pro XL?

Evaluate REC Group REC740AA Pro XL (740.0 W STC, 53.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC740AA Pro XL reaches 59.25 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 11 panels for an 8 kW build require 394 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of REC Group REC740AA Pro XL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC740AA Pro XL 8 kW Residential Fit

Needs 11 modules (394 sq ft) with a 30 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Trina Solar TSM-740NEG21C20.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 706.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC740AA Pro XL by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for REC Group REC740AA Pro XL?

Multiplying REC Group REC740AA Pro XL's 16.75 A short-circuit current by 1.56 equals 26.13 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.

### Can REC Group REC740AA Pro XL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 58.04 V cold Voc at 14 F and handles 16.75 A Isc; string inverters cap REC Group REC740AA Pro XL at 10 panels on 600 V.

### Is REC Group REC740AA Pro XL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC740AA Pro XL rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

## Related Pages

Compare REC Group equipment, Trina Solar TSM-740NEG21C20 specs, utility payback rates, and NEC string calculators alongside REC Group REC740AA Pro XL.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)
- [REC Group REC640AA Pro MG](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-mg/)