title: "REC Group REC610AA Pro M Specs (610.0W, 44.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec610aa-pro-m/
description: "CEC datasheet for REC Group REC610AA Pro M: 610.0W STC, 44.4V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC610AA Pro M — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC610AA Pro M is a 610.0 W STC (581.5 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 22.02% efficiency, 44.4 V Voc at 25 C, and 47.99 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 610.0 W

- **PTC Wattage** : 581.5 W

- **Voc @ 25C** : 44.4 V

- **Efficiency** : 22.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC610AA Pro M Compare Against Peer CEC Listings?

Engineering position of REC Group REC610AA Pro M (610.0 W STC) vs. KOSOL ENERGIE PVT LTD KE-620-66XU across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, REC Group REC610AA Pro M pairs strong 95.3% PTC-to-STC heat retention (#237 of 21,677) with 44.4 V nominal Voc. An 8 kW residential build (8,540 W DC, 8,141 W PTC) saves ~$2,137/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer KOSOL ENERGIE PVT LTD KE-620-66XU offers a 620.0 W alternative.

## Where Does REC Group REC610AA Pro M Fall Across Listed CEC Models?

Plots REC Group REC610AA Pro M at 610.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define REC Group REC610AA Pro M?

Benchmarks REC Group REC610AA Pro M on STC wattage, thermal PTC/STC retention, and 22.02 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for REC Group REC610AA Pro M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC610AA Pro M by REC Group.

Rank #1,104 / 21,677

### Top 5.6% STC Output

610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,069

### 22.02% Aperture Efficiency

Power density 220.2 W/m2 (2.11 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.99 V at -10 C (575.9 V string) and 49.02 V at -20 C (12 max).

 8 kW Reference Array

### 14 Panels = 8,540 W STC

Occupies 38.8 m2 (417 sq ft) producing 8,141 W PTC; NEC 690.8 OCPD floor is 27.39 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.4 * (1 + (-0.231/100) * (-10 - 25)) = 47.99 V | OCPD = 1.56 * 17.56 = 27.39 A

Inputs from CEC Modules.csv for REC Group REC610AA Pro M: Voc=44.4 V, beta_Voc=-0.231%/C, Isc=17.56 A, STC=610.0 W, Area=2.77 m2.

**Result:** 12 panels max on 600 V (575.9 V); 14 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for REC Group REC610AA Pro M?

Laboratory test ratings recorded for REC Group REC610AA Pro M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC610AA Pro M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 581.5 W (95.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 17.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.3 V / 16.81 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.231 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.02% (2.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC610AA Pro M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC610AA Pro M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.1 kW | 298 sq ft | $1,527 | $2,582 |
| **8 kW Class** | 14 | 8.54 kW | 417 sq ft | $2,137 | $3,614 |
| **10 kW Class** | 17 | 10.37 kW | 507 sq ft | $2,596 | $4,389 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Sibling wattage bins and frame colors grouped with REC Group REC610AA Pro M under REC Group to prevent duplicate spec pages.

Sibling CEC listings grouped into the REC Group REC610AA Pro M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC600AA Pro M** | 600.0 W | 571.8 W | 44.2 V | 35.8 V | 21.66% |
| **REC Group REC610AA Pro M** | 610.0 W | 581.5 W | 44.4 V | 36.3 V | 22.02% |
| **REC Group REC620AA Pro M** | 620.0 W | 591.3 W | 44.6 V | 36.6 V | 22.38% |

## How Many REC Group REC610AA Pro M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC610AA Pro M (beta_Voc -0.231%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=44.4V and beta_Voc=-0.231%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 49.02 V | 12 panels | 588.2 V | 20 panels |
| **-10 C (14 F)** | 47.99 V | 12 panels | 575.9 V | 20 panels |
| **0 C (32 F)** | 46.96 V | 12 panels | 563.5 V | 21 panels |
| **25 C (77 F STC)** | 44.4 V | 13 panels | 577.2 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC610AA Pro M?

Closest cross-brand CEC competitors to REC Group REC610AA Pro M matched near 610.0 W STC and 44.4 V Voc, led by KOSOL ENERGIE PVT LTD KE-620-66XU.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**KOSOL ENERGIE PVT LTD KE-620-66XU**](https://epri-peac.com/solar-equipment/modules/kosol-energie-pvt-ltd/kosol-energie-pvt-ltd-ke-620-66xu/) KOSOL ENERGIE PVT LTD | 620.0 W | +10.0 W | 44.6 V | 19.87% | 93.7% |
| [**G-Star Pte Ltd GSD8J60M-605BT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd8j60m-605bt/) G-Star Pte Ltd | 605.0 W | -5.0 W | 41.8 V | 21.53% | 94.2% |
| [**G-Star Pte Ltd GSD8J60M-605WT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd8j60m-605wt/) G-Star Pte Ltd | 605.0 W | -5.0 W | 41.8 V | 21.53% | 94.2% |
| [**Hansol Technics Co Ltd HA605ZB-GGFA0**](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha605zb-ggfa0/) Hansol Technics Co Ltd | 605.0 W | -5.0 W | 41.8 V | 21.53% | 94.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC610AA Pro M?

Evaluate REC Group REC610AA Pro M (610.0 W STC, 44.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC610AA Pro M reaches 49.02 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of REC Group REC610AA Pro M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC610AA Pro M 8 kW Residential Fit

Needs 14 modules (417 sq ft) with a 30 A string OCPD, offsetting ~$2,137/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare KOSOL ENERGIE PVT LTD KE-620-66XU.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 581.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC610AA Pro M by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for REC Group REC610AA Pro M?

Multiplying REC Group REC610AA Pro M's 17.56 A short-circuit current by 1.56 equals 27.39 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.

### Can REC Group REC610AA Pro M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.99 V cold Voc at 14 F and handles 17.56 A Isc; string inverters cap REC Group REC610AA Pro M at 12 panels on 600 V.

### Is REC Group REC610AA Pro M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC610AA Pro M rely on utility bill offset (~$2,137/yr at 8 kW) rather than 25D.

## Related Pages

Compare REC Group equipment, KOSOL ENERGIE PVT LTD KE-620-66XU specs, utility payback rates, and NEC string calculators alongside REC Group REC610AA Pro M.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)