title: "REC Group REC475AA Pure-RX Specs (475.0W, 65.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec475aa-pure-rx/
description: "CEC datasheet for REC Group REC475AA Pure-RX: 475.0W STC, 65.7V Voc, 17-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC475AA Pure-RX — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC475AA Pure-RX is a 475.0 W STC (453.5 W PTC) Mono-c-Si solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 23.51% efficiency, 65.7 V Voc at 25 C, and 71.06 V cold Voc at -10 C (8 panels max per 600 V string).

- **STC Wattage** : 475.0 W

- **PTC Wattage** : 453.5 W

- **Voc @ 25C** : 65.7 V

- **Efficiency** : 23.51%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC475AA Pure-RX Compare Against Peer CEC Listings?

How REC Group REC Group REC475AA Pure-RX handles rooftop heat (453.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, REC Group REC475AA Pure-RX exhibits 9.0 A short-circuit current, requiring a 14.04 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #4,892 of 21,677 (65.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 34.3 m2 for an 8 kW system (22 panels for 10 kW). Higher 65.7 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C).

## Where Does REC Group REC475AA Pure-RX Fall Across Listed CEC Models?

Where REC Group REC475AA Pure-RX (475.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define REC Group REC475AA Pure-RX?

Percentile placement of REC Group REC475AA Pure-RX across power density (235.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for REC Group REC475AA Pure-RX?

Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC475AA Pure-RX specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #4,892 / 21,677

### Top 22.9% STC Output

475.0 W STC (+90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #500

### 23.51% Aperture Efficiency

Power density 235.1 W/m2 (3.60 percentage points above 19.91% CEC median). PTC/STC ratio: 95.5% (rank #102).

NEC 690.7 Limit

### 8 Panels Max @ -10 C (600 V)

Cold Voc reaches 71.06 V at -10 C (568.5 V string) and 72.59 V at -20 C (8 max).

 8 kW Reference Array

### 17 Panels = 8,075 W STC

Occupies 34.3 m2 (370 sq ft) producing 7,710 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 65.7 * (1 + (-0.233/100) * (-10 - 25)) = 71.06 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for REC Group REC475AA Pure-RX: Voc=65.7 V, beta_Voc=-0.233%/C, Isc=9.0 A, STC=475.0 W, Area=2.02 m2.

**Result:** 8 panels max on 600 V (568.5 V); 17 panels for 8 kW (370 sq ft).

## What Are the Published CEC Specifications for REC Group REC475AA Pure-RX?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC475AA Pure-RX.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC475AA Pure-RX.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 475.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 453.5 W (95.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 65.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 55.5 V / 8.56 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.233 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.51% (2.02 m2) | Array roof footprint density |
| **Cell Count & Technology** | 88 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC475AA Pure-RX Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC475AA Pure-RX (475.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.17 kW | 283 sq ft | $1,544 | $2,611 |
| **8 kW Class** | 17 | 8.07 kW | 370 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 22 | 10.45 kW | 478 sq ft | $2,616 | $4,423 |

## How Many REC Group REC475AA Pure-RX Modules Fit in a Cold-Weather String?

Maximum series module counts for REC Group REC475AA Pure-RX from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=65.7V and beta_Voc=-0.233%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 72.59 V | 8 panels | 580.7 V | 13 panels |
| **-10 C (14 F)** | 71.06 V | 8 panels | 568.5 V | 14 panels |
| **0 C (32 F)** | 69.53 V | 8 panels | 556.2 V | 14 panels |
| **25 C (77 F STC)** | 65.7 V | 9 panels | 591.3 V | 15 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC475AA Pure-RX?

Alternative CEC solar modules from competing brands near REC Group REC475AA Pure-RX (475.0 W), including Heliene 96M475. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Heliene 96M475**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m475/) Heliene | 475.0 W | Tie (0 W) | 62.39 V | 18.85% | 90.5% |
| [**Heliene 96M460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m460/) Heliene | 460.0 W | -15.0 W | 61.79 V | 18.25% | 90.4% |
| [**CSI Solar Co Ltd CS3Y-480P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-480p/) CSI Solar Co Ltd | 480.0 W | +5.0 W | 52.8 V | 20.96% | 93.2% |
| [**CSI Solar Co Ltd CS3Y-470MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-470ms/) CSI Solar Co Ltd | 470.0 W | -5.0 W | 52.5 V | 20.52% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC475AA Pure-RX?

Evaluate REC Group REC475AA Pure-RX (475.0 W STC, 65.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC475AA Pure-RX reaches 72.59 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 370 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (370 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC475AA Pure-RX carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC475AA Pure-RX 8 kW Residential Fit

Needs 17 modules (370 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Heliene 96M475.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 453.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC475AA Pure-RX by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is REC Group REC475AA Pure-RX PTC wattage (453.5 W) lower than STC (475.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 453.5 W PTC (95.5% retention) across REC Group REC475AA Pure-RX's 2.02 m2 aperture.

### Who should skip REC Group REC475AA Pure-RX on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 REC Group REC475AA Pure-RX panels (370 sq ft) leave unusable roof gaps vs. Heliene 96M475.

### What is the 1,000 V commercial string limit for REC Group REC475AA Pure-RX?

On 1,000 V commercial inverters at -10 C (71.06 V cold Voc), REC Group REC475AA Pure-RX fits up to 14 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting REC Group REC475AA Pure-RX.

## Related Pages

Compare REC Group equipment, Heliene 96M475 specs, utility payback rates, and NEC string calculators alongside REC Group REC475AA Pure-RX.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)