title: "REC Group REC460AA Pure-RXG Specs (460.0W, 65.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec460aa-pure-rxg/
description: "CEC datasheet for REC Group REC460AA Pure-RXG: 460.0W STC, 65.8V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC460AA Pure-RXG — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC460AA Pure-RXG is a 460.0 W STC (440.1 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 22.77% efficiency, 65.8 V Voc at 25 C, and 71.12 V cold Voc at -10 C (8 panels max per 600 V string).

- **STC Wattage** : 460.0 W

- **PTC Wattage** : 440.1 W

- **Voc @ 25C** : 65.8 V

- **Efficiency** : 22.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC460AA Pure-RXG Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC460AA Pure-RXG (Mono-c-Si) residential solar systems.

REC Group REC460AA Pure-RXG delivers 227.7 W/m2 (2.86 percentage points above 19.91% CEC median) and strong 95.7% PTC-to-STC heat retention (#47 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 72.64 V per unit, capping 600 V circuits at 8 panels. Compare specs directly with Heliene 96M460 (460.0 W).

## Where Does REC Group REC460AA Pure-RXG Fall Across Listed CEC Models?

Comparison of REC Group REC460AA Pure-RXG (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define REC Group REC460AA Pure-RXG?

Relative ranking of REC Group REC460AA Pure-RXG across nameplate watts, 95.7% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for REC Group REC460AA Pure-RXG?

Summary of REC Group REC460AA Pure-RXG output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,199 / 21,677

### Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,520

### 22.77% Aperture Efficiency

Power density 227.7 W/m2 (2.86 percentage points above 19.91% CEC median). PTC/STC ratio: 95.7% (rank #47).

NEC 690.7 Limit

### 8 Panels Max @ -10 C (600 V)

Cold Voc reaches 71.12 V at -10 C (569.0 V string) and 72.64 V at -20 C (8 max).

 8 kW Reference Array

### 18 Panels = 8,280 W STC

Occupies 36.4 m2 (391 sq ft) producing 7,922 W PTC; NEC 690.8 OCPD floor is 13.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 65.8 * (1 + (-0.231/100) * (-10 - 25)) = 71.12 V | OCPD = 1.56 * 8.88 = 13.85 A

Inputs from CEC Modules.csv for REC Group REC460AA Pure-RXG: Voc=65.8 V, beta_Voc=-0.231%/C, Isc=8.88 A, STC=460.0 W, Area=2.02 m2.

**Result:** 8 panels max on 600 V (569.0 V); 18 panels for 8 kW (391 sq ft).

## What Are the Published CEC Specifications for REC Group REC460AA Pure-RXG?

Complete CEC test sheet for REC Group REC460AA Pure-RXG including Isc (8.88 A), Voc (65.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC460AA Pure-RXG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 440.1 W (95.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 65.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 54.9 V / 8.38 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.231 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.77% (2.02 m2) | Array roof footprint density |
| **Cell Count & Technology** | 44 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC460AA Pure-RXG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC460AA Pure-RXG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.44 kW | 304 sq ft | $1,612 | $2,726 |
| **8 kW Class** | 18 | 8.28 kW | 391 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 22 | 10.12 kW | 478 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC460AA Pure-RXG series guide.

Sibling CEC listings grouped into the REC Group REC460AA Pure-RXG wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC450AA Pure-RXG** | 450.0 W | 430.4 W | 65.6 V | 54.3 V | 22.28% |
| **REC Group REC460AA Pure-RXG** | 460.0 W | 440.1 W | 65.8 V | 54.9 V | 22.77% |

## How Many REC Group REC460AA Pure-RXG Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC460AA Pure-RXG (65.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=65.8V and beta_Voc=-0.231%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 72.64 V | 8 panels | 581.1 V | 13 panels |
| **-10 C (14 F)** | 71.12 V | 8 panels | 569.0 V | 14 panels |
| **0 C (32 F)** | 69.6 V | 8 panels | 556.8 V | 14 panels |
| **25 C (77 F STC)** | 65.8 V | 9 panels | 592.2 V | 15 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC460AA Pure-RXG?

Four comparable CEC modules such as Heliene 96M460 (460.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Heliene 96M460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m460/) Heliene | 460.0 W | Tie (0 W) | 61.79 V | 18.25% | 90.4% |
| [**Heliene 96M475**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-96m475/) Heliene | 475.0 W | +15.0 W | 62.39 V | 18.85% | 90.5% |
| [**CSI Solar Co Ltd CS3Y-460P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-460p/) CSI Solar Co Ltd | 460.0 W | Tie (0 W) | 52.0 V | 20.09% | 93.1% |
| [**Heliene 144HC-460**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-144hc-460/) Heliene | 460.0 W | Tie (0 W) | 51.26 V | 20.81% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC460AA Pure-RXG?

Evaluate REC Group REC460AA Pure-RXG (460.0 W STC, 65.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC460AA Pure-RXG reaches 72.64 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 391 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC460AA Pure-RXG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC460AA Pure-RXG 8 kW Residential Fit

Needs 18 modules (391 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Heliene 96M460.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 440.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC460AA Pure-RXG by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### How many REC Group REC460AA Pure-RXG panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC460AA Pure-RXG cold Voc rises from 65.8 V to 71.12 V (beta_Voc -0.231%/C), capping a 600 V string at 8 panels (569.0 V).

### How much roof area does an 8 kW array of REC Group REC460AA Pure-RXG need?

An 8 kW DC system uses 18 REC Group REC460AA Pure-RXG modules (8,280 W STC / 7,922 W PTC), covering roughly 391 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

### How does REC Group REC460AA Pure-RXG compare against Heliene 96M460?

REC Group REC460AA Pure-RXG outputs 460.0 W STC (65.8 V Voc, rank #5,199 of 21,677), while Heliene 96M460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare REC Group equipment, Heliene 96M460 specs, utility payback rates, and NEC string calculators alongside REC Group REC460AA Pure-RXG.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)