title: "REC Group REC450AA 72 XV Specs (450.0W, 53.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec450aa-72-xv/
description: "CEC datasheet for REC Group REC450AA 72 XV: 450.0W STC, 53.2V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC450AA 72 XV — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC450AA 72 XV is a 450.0 W STC (427.0 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.9% efficiency, 53.2 V Voc at 25 C, and 57.58 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 450.0 W

- **PTC Wattage** : 427.0 W

- **Voc @ 25C** : 53.2 V

- **Efficiency** : 21.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC450AA 72 XV Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC450AA 72 XV: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC450AA 72 XV stands 40.0 W above the 410.0 W Mono-c-Si median and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,577-$2,591/yr in baseline US bill offset. Higher 53.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does REC Group REC450AA 72 XV Fall Across Listed CEC Models?

Distribution marker showing REC Group REC450AA 72 XV (450.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define REC Group REC450AA 72 XV?

Dataset percentiles tracking REC Group REC450AA 72 XV power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for REC Group REC450AA 72 XV?

Benchmark highlights for REC Group REC450AA 72 XV covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,679 / 21,677

### Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,316

### 21.9% Aperture Efficiency

Power density 219.0 W/m2 (1.99 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.58 V at -10 C (575.8 V string) and 58.83 V at -20 C (10 max).

 8 kW Reference Array

### 18 Panels = 8,100 W STC

Occupies 37.0 m2 (398 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 16.27 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.2 * (1 + (-0.235/100) * (-10 - 25)) = 57.58 V | OCPD = 1.56 * 10.43 = 16.27 A

Inputs from CEC Modules.csv for REC Group REC450AA 72 XV: Voc=53.2 V, beta_Voc=-0.235%/C, Isc=10.43 A, STC=450.0 W, Area=2.055 m2.

**Result:** 10 panels max on 600 V (575.8 V); 18 panels for 8 kW (398 sq ft).

## What Are the Published CEC Specifications for REC Group REC450AA 72 XV?

Official CEC datasheet figures for REC Group REC450AA 72 XV (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC450AA 72 XV.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 427.0 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.3 V / 9.72 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.235 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.9% (2.055 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC450AA 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC450AA 72 XV modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.3 kW | 310 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 18 | 8.1 kW | 398 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 23 | 10.35 kW | 509 sq ft | $2,591 | $4,380 |

## How Many REC Group REC450AA 72 XV Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC450AA 72 XV (57.58 V at 14 F).

Computed from Voc=53.2V and beta_Voc=-0.235%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 58.83 V | 10 panels | 588.3 V | 16 panels |
| **-10 C (14 F)** | 57.58 V | 10 panels | 575.8 V | 17 panels |
| **0 C (32 F)** | 56.33 V | 10 panels | 563.3 V | 17 panels |
| **25 C (77 F STC)** | 53.2 V | 11 panels | 585.2 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC450AA 72 XV?

Competing CEC solar panels closest to REC Group REC450AA 72 XV in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m144-hc-450w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
| [**AXITEC AC-450MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-450mh-144v/) AXITEC | 450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M772W 450W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m772w-450w/) Dehui Solar Power (Vietnam) CoLtd | 450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
| [**FreeVolt ECP-PVGRAF-144HC-450W**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-144hc-450w/) FreeVolt | 450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC450AA 72 XV?

Evaluate REC Group REC450AA 72 XV (450.0 W STC, 53.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC450AA 72 XV reaches 58.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 398 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (398 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC450AA 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC450AA 72 XV 8 kW Residential Fit

Needs 18 modules (398 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 427.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC450AA 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for REC Group REC450AA 72 XV?

Multiplying REC Group REC450AA 72 XV's 10.43 A short-circuit current by 1.56 equals 16.27 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can REC Group REC450AA 72 XV pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.58 V cold Voc at 14 F and handles 10.43 A Isc; string inverters cap REC Group REC450AA 72 XV at 10 panels on 600 V.

### Is REC Group REC450AA 72 XV eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC450AA 72 XV rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare REC Group equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W specs, utility payback rates, and NEC string calculators alongside REC Group REC450AA 72 XV.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)