title: "REC Group REC430AA Pure 2 Specs (430.0W, 49.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec430aa-pure-2/
description: "CEC datasheet for REC Group REC430AA Pure 2: 430.0W STC, 49.0V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC430AA Pure 2 — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC430AA Pure 2 is a 430.0 W STC (413.1 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 22.87% efficiency, 49.0 V Voc at 25 C, and 53.03 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 430.0 W

- **PTC Wattage** : 413.1 W

- **Voc @ 25C** : 49.0 V

- **Efficiency** : 22.87%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC430AA Pure 2 Compare Against Peer CEC Listings?

Engineering position of REC Group REC430AA Pure 2 (430.0 W STC) vs. AXITEC AC-435MB/144V across 5,889 CEC Mono-c-Si solar modules.

Built with 66 Mono-c-Si cells, REC Group REC430AA Pure 2 pairs strong 96.1% PTC-to-STC heat retention (#17 of 21,677) with 49.0 V nominal Voc. An 8 kW residential build (8,170 W DC, 7,849 W PTC) saves ~$2,045/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AXITEC AC-435MB/144V offers a 435.0 W alternative.

## Where Does REC Group REC430AA Pure 2 Fall Across Listed CEC Models?

Plots REC Group REC430AA Pure 2 at 430.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define REC Group REC430AA Pure 2?

Benchmarks REC Group REC430AA Pure 2 on STC wattage, thermal PTC/STC retention, and 22.87 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for REC Group REC430AA Pure 2?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC430AA Pure 2 by REC Group.

Rank #7,266 / 21,677

### Top 35.2% STC Output

430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,348

### 22.87% Aperture Efficiency

Power density 228.7 W/m2 (2.96 percentage points above 19.91% CEC median). PTC/STC ratio: 96.1% (rank #17).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.03 V at -10 C (583.3 V string) and 54.18 V at -20 C (11 max).

 8 kW Reference Array

### 19 Panels = 8,170 W STC

Occupies 35.7 m2 (384 sq ft) producing 7,849 W PTC; NEC 690.8 OCPD floor is 16.86 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.235/100) * (-10 - 25)) = 53.03 V | OCPD = 1.56 * 10.81 = 16.86 A

Inputs from CEC Modules.csv for REC Group REC430AA Pure 2: Voc=49.0 V, beta_Voc=-0.235%/C, Isc=10.81 A, STC=430.0 W, Area=1.88 m2.

**Result:** 11 panels max on 600 V (583.3 V); 19 panels for 8 kW (384 sq ft).

## What Are the Published CEC Specifications for REC Group REC430AA Pure 2?

Laboratory test ratings recorded for REC Group REC430AA Pure 2 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC430AA Pure 2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 430.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 413.1 W (96.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.81 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.8 V / 10.05 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.235 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.87% (1.88 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC430AA Pure 2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (384 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC430AA Pure 2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.02 kW | 283 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 19 | 8.17 kW | 384 sq ft | $2,045 | $3,458 |
| **10 kW Class** | 24 | 10.32 kW | 486 sq ft | $2,583 | $4,368 |

## How Many REC Group REC430AA Pure 2 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC430AA Pure 2 (beta_Voc -0.235%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.0V and beta_Voc=-0.235%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.18 V | 11 panels | 596.0 V | 18 panels |
| **-10 C (14 F)** | 53.03 V | 11 panels | 583.3 V | 18 panels |
| **0 C (32 F)** | 51.88 V | 11 panels | 570.7 V | 19 panels |
| **25 C (77 F STC)** | 49.0 V | 12 panels | 588.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC430AA Pure 2?

Closest cross-brand CEC competitors to REC Group REC430AA Pure 2 matched near 430.0 W STC and 49.0 V Voc, led by AXITEC AC-435MB/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-435MB/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-435mb-144v/) AXITEC | 435.0 W | +5.0 W | 49.1 V | 20.33% | 92.6% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m772f-435w/) Dehui Solar Power (Vietnam) CoLtd | 435.0 W | +5.0 W | 49.1 V | 20.33% | 92.6% |
| [**Caterpillar Inc PVC435MP03H**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc435mp03h/) Caterpillar Inc | 435.0 W | +5.0 W | 48.7 V | 20.52% | 93.6% |
| [**AXITEC AC-435MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-435mh-144v/) AXITEC | 435.0 W | +5.0 W | 49.4 V | 20.52% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC430AA Pure 2?

Evaluate REC Group REC430AA Pure 2 (430.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC430AA Pure 2 reaches 54.18 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 384 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (384 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC430AA Pure 2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC430AA Pure 2 8 kW Residential Fit

Needs 19 modules (384 sq ft) with a 20 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-435MB/144V.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 413.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC430AA Pure 2 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for REC Group REC430AA Pure 2?

Multiplying REC Group REC430AA Pure 2's 10.81 A short-circuit current by 1.56 equals 16.86 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can REC Group REC430AA Pure 2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.03 V cold Voc at 14 F and handles 10.81 A Isc; string inverters cap REC Group REC430AA Pure 2 at 11 panels on 600 V.

### Is REC Group REC430AA Pure 2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC430AA Pure 2 rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

## Related Pages

Compare REC Group equipment, AXITEC AC-435MB/144V specs, utility payback rates, and NEC string calculators alongside REC Group REC430AA Pure 2.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)