Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC410NP3 Black is a 410.0 W STC (383.1 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.35% efficiency, 45.2 V Voc at 25 C, and 49.3 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 383.1 W

- **Voc @ 25C** : 45.2 V

- **Efficiency** : 21.35%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC410NP3 Black Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC410NP3 Black: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 410.0 W STC and 383.1 W PTC, REC Group REC410NP3 Black sits +25.0 W vs all-CEC median (top 41.3%; higher than 58.7% of peers) among 21,677 listed modules. Power density reaches 213.5 W/m2 (1.44 percentage points above 19.91% CEC median). Mid-range 45.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer CSI Solar Co Ltd CS3N-410MS {Blk} rates 410.0 W.

## Where Does REC Group REC410NP3 Black Fall Across Listed CEC Models?

Distribution marker showing REC Group REC410NP3 Black (410.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define REC Group REC410NP3 Black?

Dataset percentiles tracking REC Group REC410NP3 Black power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for REC Group REC410NP3 Black?

Benchmark highlights for REC Group REC410NP3 Black covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,922

### 21.35% Aperture Efficiency

Power density 213.5 W/m2 (1.44 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.3 V at -10 C (591.6 V string) and 50.47 V at -20 C (11 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,662 W PTC; NEC 690.8 OCPD floor is 17.89 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.2 * (1 + (-0.259/100) * (-10 - 25)) = 49.3 V | OCPD = 1.56 * 11.47 = 17.89 A

Inputs from CEC Modules.csv for REC Group REC410NP3 Black: Voc=45.2 V, beta_Voc=-0.259%/C, Isc=11.47 A, STC=410.0 W, Area=1.92 m2.

**Result:** 12 panels max on 600 V (591.6 V); 20 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for REC Group REC410NP3 Black?

Official CEC datasheet figures for REC Group REC410NP3 Black (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC410NP3 Black.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 383.1 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.47 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.3 V / 10.71 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.259 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.35% (1.92 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC410NP3 Black Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC410NP3 Black modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 310 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 413 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 517 sq ft | $2,565 | $4,338 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Consolidated REC Group wattage variants sharing the REC Group REC410NP3 Black mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the REC Group REC410NP3 Black wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC400NP3 Black** | 400.0 W | 373.5 W | 45.0 V | 37.6 V | 20.83% |
| **REC Group REC410NP3 Black** | 410.0 W | 383.1 W | 45.2 V | 38.3 V | 21.35% |

## How Many REC Group REC410NP3 Black Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC410NP3 Black (49.3 V at 14 F).

Computed from Voc=45.2V and beta_Voc=-0.259%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.47 V | 11 panels | 555.2 V | 19 panels |
| **-10 C (14 F)** | 49.3 V | 12 panels | 591.6 V | 20 panels |
| **0 C (32 F)** | 48.13 V | 12 panels | 577.6 V | 20 panels |
| **25 C (77 F STC)** | 45.2 V | 13 panels | 587.6 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC410NP3 Black?

Competing CEC solar panels closest to REC Group REC410NP3 Black in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3N-410MS {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3N-410MS {Blk}**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3n-410ms-blk/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 44.9 V | 20.81% | 93.5% |
| [**CSI Solar Co Ltd CS3N-405MS {Wht}**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3n-405ms-wht/) CSI Solar Co Ltd | 405.0 W | -5.0 W | 44.7 V | 20.56% | 93.5% |
| [**CSI Solar Co Ltd CS3W-410P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3w-410p/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 47.6 V | 19.16% | 93.2% |
| [**AXITEC AC-410MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mh-144v/) AXITEC | 410.0 W | Tie (0 W) | 48.91 V | 20.71% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC410NP3 Black?

Evaluate REC Group REC410NP3 Black (410.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC410NP3 Black reaches 50.47 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 413 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (413 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC410NP3 Black carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC410NP3 Black 8 kW Residential Fit

Needs 20 modules (413 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-410MS {Blk}.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC410NP3 Black by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### How many REC Group REC410NP3 Black panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC410NP3 Black cold Voc rises from 45.2 V to 49.3 V (beta_Voc -0.259%/C), capping a 600 V string at 12 panels (591.6 V).

### How much roof area does an 8 kW array of REC Group REC410NP3 Black need?

An 8 kW DC system uses 20 REC Group REC410NP3 Black modules (8,200 W STC / 7,662 W PTC), covering roughly 413 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

### How does REC Group REC410NP3 Black compare against CSI Solar Co Ltd CS3N-410MS {Blk}?

REC Group REC410NP3 Black outputs 410.0 W STC (45.2 V Voc, rank #8,539 of 21,677), while CSI Solar Co Ltd CS3N-410MS {Blk} delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare REC Group equipment, CSI Solar Co Ltd CS3N-410MS {Blk} specs, utility payback rates, and NEC string calculators alongside REC Group REC410NP3 Black.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)