title: "REC Group REC410AA Pure 2 Specs (410.0W, 48.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec410aa-pure-2/
description: "CEC datasheet for REC Group REC410AA Pure 2: 410.0W STC, 48.6V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC410AA Pure 2 — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC410AA Pure 2 is a 410.0 W STC (393.6 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.81% efficiency, 48.6 V Voc at 25 C, and 52.6 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 393.6 W

- **Voc @ 25C** : 48.6 V

- **Efficiency** : 21.81%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC410AA Pure 2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC410AA Pure 2 (Mono-c-Si) residential solar systems.

Homeowners evaluating REC Group REC410AA Pure 2 need 15 panels for 6 kW or 20 panels (405 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (405 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.235%/C) pushes open-circuit voltage to 52.6 V at 14 F and 53.74 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does REC Group REC410AA Pure 2 Fall Across Listed CEC Models?

Comparison of REC Group REC410AA Pure 2 (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define REC Group REC410AA Pure 2?

Relative ranking of REC Group REC410AA Pure 2 across nameplate watts, 96.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for REC Group REC410AA Pure 2?

Summary of REC Group REC410AA Pure 2 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,564

### 21.81% Aperture Efficiency

Power density 218.1 W/m2 (1.90 percentage points above 19.91% CEC median). PTC/STC ratio: 96.0% (rank #21).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.6 V at -10 C (578.6 V string) and 53.74 V at -20 C (11 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 37.6 m2 (405 sq ft) producing 7,872 W PTC; NEC 690.8 OCPD floor is 16.65 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.6 * (1 + (-0.235/100) * (-10 - 25)) = 52.6 V | OCPD = 1.56 * 10.67 = 16.65 A

Inputs from CEC Modules.csv for REC Group REC410AA Pure 2: Voc=48.6 V, beta_Voc=-0.235%/C, Isc=10.67 A, STC=410.0 W, Area=1.88 m2.

**Result:** 11 panels max on 600 V (578.6 V); 20 panels for 8 kW (405 sq ft).

## What Are the Published CEC Specifications for REC Group REC410AA Pure 2?

Complete CEC test sheet for REC Group REC410AA Pure 2 including Isc (10.67 A), Voc (48.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC410AA Pure 2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 393.6 W (96.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.6 V / 9.86 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.235 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.81% (1.88 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC410AA Pure 2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC410AA Pure 2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 304 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 405 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 506 sq ft | $2,565 | $4,338 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC410AA Pure 2 series guide.

Sibling CEC listings grouped into the REC Group REC410AA Pure 2 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC400AA Pure 2** | 400.0 W | 383.8 W | 48.5 V | 41.1 V | 21.28% |
| **REC Group REC410AA Pure 2** | 410.0 W | 393.6 W | 48.6 V | 41.6 V | 21.81% |
| **REC Group REC420AA Pure 2** | 420.0 W | 403.3 W | 48.8 V | 42.2 V | 22.34% |

## How Many REC Group REC410AA Pure 2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC410AA Pure 2 (48.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.6V and beta_Voc=-0.235%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.74 V | 11 panels | 591.1 V | 18 panels |
| **-10 C (14 F)** | 52.6 V | 11 panels | 578.6 V | 19 panels |
| **0 C (32 F)** | 51.46 V | 11 panels | 566.1 V | 19 panels |
| **25 C (77 F STC)** | 48.6 V | 12 panels | 583.2 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC410AA Pure 2?

Four comparable CEC modules such as AXITEC AC-410MH/144V (410.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-410MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mh-144v/) AXITEC | 410.0 W | Tie (0 W) | 48.91 V | 20.71% | 93.5% |
| [**BYD Company Limited BYD400MIK-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd400mik-36/) BYD Company Limited | 410.0 W | Tie (0 W) | 49.21 V | 20.4% | 94.0% |
| [**AXITEC AC-410MB/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mb-144v/) AXITEC | 410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m872w-410w/) Dehui Solar Power (Vietnam) CoLtd | 410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC410AA Pure 2?

Evaluate REC Group REC410AA Pure 2 (410.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC410AA Pure 2 reaches 53.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (405 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC410AA Pure 2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC410AA Pure 2 8 kW Residential Fit

Needs 20 modules (405 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-410MH/144V.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 393.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC410AA Pure 2 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is REC Group REC410AA Pure 2 PTC wattage (393.6 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 393.6 W PTC (96.0% retention) across REC Group REC410AA Pure 2's 1.88 m2 aperture.

### Who should skip REC Group REC410AA Pure 2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 REC Group REC410AA Pure 2 panels (405 sq ft) leave unusable roof gaps vs. AXITEC AC-410MH/144V.

### What is the 1,000 V commercial string limit for REC Group REC410AA Pure 2?

On 1,000 V commercial inverters at -10 C (52.6 V cold Voc), REC Group REC410AA Pure 2 fits up to 19 panels per series string.

## Related Pages

Compare REC Group equipment, AXITEC AC-410MH/144V specs, utility payback rates, and NEC string calculators alongside REC Group REC410AA Pure 2.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)