# REC Group REC400TP2SM 72 XV BLK — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC400TP2SM 72 XV BLK is a 400.0 W STC (376.3 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.54% efficiency, 49.0 V Voc at 25 C, and 53.89 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 400.0 W

- **PTC Wattage** : 376.3 W

- **Voc @ 25C** : 49.0 V

- **Efficiency** : 20.54%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC400TP2SM 72 XV BLK Compare Against Peer CEC Listings?

Engineering position of REC Group REC400TP2SM 72 XV BLK (400.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-400-H across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, REC Group REC400TP2SM 72 XV BLK pairs strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677) with 49.0 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,526 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612M-400-H offers a 400.0 W alternative.

## Where Does REC Group REC400TP2SM 72 XV BLK Fall Across Listed CEC Models?

Plots REC Group REC400TP2SM 72 XV BLK at 400.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define REC Group REC400TP2SM 72 XV BLK?

Benchmarks REC Group REC400TP2SM 72 XV BLK on STC wattage, thermal PTC/STC retention, and 20.54 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for REC Group REC400TP2SM 72 XV BLK?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC400TP2SM 72 XV BLK by REC Group.

Rank #9,407 / 21,677

### Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,364

### 20.54% Aperture Efficiency

Power density 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.89 V at -10 C (592.8 V string) and 55.28 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,000 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.285/100) * (-10 - 25)) = 53.89 V | OCPD = 1.56 * 10.2 = 15.91 A

Inputs from CEC Modules.csv for REC Group REC400TP2SM 72 XV BLK: Voc=49.0 V, beta_Voc=-0.285%/C, Isc=10.2 A, STC=400.0 W, Area=1.947 m2.

**Result:** 11 panels max on 600 V (592.8 V); 20 panels for 8 kW (419 sq ft).

## What Are the Published CEC Specifications for REC Group REC400TP2SM 72 XV BLK?

Laboratory test ratings recorded for REC Group REC400TP2SM 72 XV BLK (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC400TP2SM 72 XV BLK.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 376.3 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.1 V / 9.73 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.285 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.54% (1.947 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC400TP2SM 72 XV BLK Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (419 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC400TP2SM 72 XV BLK.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.0 kW | 314 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 20 | 8.0 kW | 419 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 25 | 10.0 kW | 524 sq ft | $2,503 | $4,232 |

## How Many REC Group REC400TP2SM 72 XV BLK Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC400TP2SM 72 XV BLK (beta_Voc -0.285%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.0V and beta_Voc=-0.285%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.28 V | 10 panels | 552.8 V | 18 panels |
| **-10 C (14 F)** | 53.89 V | 11 panels | 592.8 V | 18 panels |
| **0 C (32 F)** | 52.49 V | 11 panels | 577.4 V | 19 panels |
| **25 C (77 F STC)** | 49.0 V | 12 panels | 588.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC400TP2SM 72 XV BLK?

Closest cross-brand CEC competitors to REC Group REC400TP2SM 72 XV BLK matched near 400.0 W STC and 49.0 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-bhc-405w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 405.0 W | +5.0 W | 49.1 V | 20.77% | 93.0% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M872F 405W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m872f-405w/) Dehui Solar Power (Vietnam) CoLtd | 405.0 W | +5.0 W | 49.1 V | 20.77% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC400TP2SM 72 XV BLK?

Evaluate REC Group REC400TP2SM 72 XV BLK (400.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC400TP2SM 72 XV BLK reaches 55.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC400TP2SM 72 XV BLK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC400TP2SM 72 XV BLK 8 kW Residential Fit

Needs 20 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 376.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC400TP2SM 72 XV BLK by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for REC Group REC400TP2SM 72 XV BLK?

Multiplying REC Group REC400TP2SM 72 XV BLK's 10.2 A short-circuit current by 1.56 equals 15.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can REC Group REC400TP2SM 72 XV BLK pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.89 V cold Voc at 14 F and handles 10.2 A Isc; string inverters cap REC Group REC400TP2SM 72 XV BLK at 11 panels on 600 V.

### Is REC Group REC400TP2SM 72 XV BLK eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC400TP2SM 72 XV BLK rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

## Related Pages

Compare REC Group equipment, Boviet Solar Technology Co Ltd BVM6612M-400-H specs, utility payback rates, and NEC string calculators alongside REC Group REC400TP2SM 72 XV BLK.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)