title: "REC Group REC400NP 72 Specs (400.0W, 49.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec400np-72/
description: "CEC datasheet for REC Group REC400NP 72: 400.0W STC, 49.4V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC400NP 72 — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC400NP 72 is a 400.0 W STC (374.2 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.54% efficiency, 49.4 V Voc at 25 C, and 54.0 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 400.0 W

- **PTC Wattage** : 374.2 W

- **Voc @ 25C** : 49.4 V

- **Efficiency** : 20.54%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC400NP 72 Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC400NP 72: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 400.0 W STC and 374.2 W PTC, REC Group REC400NP 72 sits +15.0 W vs all-CEC median (top 45.5%; higher than 54.5% of peers) among 21,677 listed modules. Power density reaches 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-400-H rates 400.0 W.

## Where Does REC Group REC400NP 72 Fall Across Listed CEC Models?

Distribution marker showing REC Group REC400NP 72 (400.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define REC Group REC400NP 72?

Dataset percentiles tracking REC Group REC400NP 72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for REC Group REC400NP 72?

Benchmark highlights for REC Group REC400NP 72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,407 / 21,677

### Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,364

### 20.54% Aperture Efficiency

Power density 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.0 V at -10 C (594.0 V string) and 55.31 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,000 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,484 W PTC; NEC 690.8 OCPD floor is 16.22 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.266/100) * (-10 - 25)) = 54.0 V | OCPD = 1.56 * 10.4 = 16.22 A

Inputs from CEC Modules.csv for REC Group REC400NP 72: Voc=49.4 V, beta_Voc=-0.266%/C, Isc=10.4 A, STC=400.0 W, Area=1.947 m2.

**Result:** 11 panels max on 600 V (594.0 V); 20 panels for 8 kW (419 sq ft).

## What Are the Published CEC Specifications for REC Group REC400NP 72?

Official CEC datasheet figures for REC Group REC400NP 72 (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC400NP 72.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 374.2 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.7 V / 9.84 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.266 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.54% (1.947 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC400NP 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC400NP 72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.0 kW | 314 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 20 | 8.0 kW | 419 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 25 | 10.0 kW | 524 sq ft | $2,503 | $4,232 |

## How Many REC Group REC400NP 72 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC400NP 72 (54.0 V at 14 F).

Computed from Voc=49.4V and beta_Voc=-0.266%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.31 V | 10 panels | 553.1 V | 18 panels |
| **-10 C (14 F)** | 54.0 V | 11 panels | 594.0 V | 18 panels |
| **0 C (32 F)** | 52.69 V | 11 panels | 579.6 V | 18 panels |
| **25 C (77 F STC)** | 49.4 V | 12 panels | 592.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC400NP 72?

Competing CEC solar panels closest to REC Group REC400NP 72 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h/) Boviet Solar Technology Co Ltd | 405.0 W | +5.0 W | 49.45 V | 20.35% | 93.3% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc/) Boviet Solar Technology Co Ltd | 405.0 W | +5.0 W | 49.45 V | 19.95% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC400NP 72?

Evaluate REC Group REC400NP 72 (400.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC400NP 72 reaches 55.31 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC400NP 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC400NP 72 8 kW Residential Fit

Needs 20 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 374.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC400NP 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### How many REC Group REC400NP 72 panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC400NP 72 cold Voc rises from 49.4 V to 54.0 V (beta_Voc -0.266%/C), capping a 600 V string at 11 panels (594.0 V).

### How much roof area does an 8 kW array of REC Group REC400NP 72 need?

An 8 kW DC system uses 20 REC Group REC400NP 72 modules (8,000 W STC / 7,484 W PTC), covering roughly 419 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does REC Group REC400NP 72 compare against Boviet Solar Technology Co Ltd BVM6612M-400-H?

REC Group REC400NP 72 outputs 400.0 W STC (49.4 V Voc, rank #9,407 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-400-H delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare REC Group equipment, Boviet Solar Technology Co Ltd BVM6612M-400-H specs, utility payback rates, and NEC string calculators alongside REC Group REC400NP 72.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)