title: "REC Group REC400NP 72 XV Specs (400.0W, 49.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec400np-72-xv/
description: "CEC datasheet for REC Group REC400NP 72 XV: 400.0W STC, 49.4V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC400NP 72 XV — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC400NP 72 XV is a 400.0 W STC (374.2 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.54% efficiency, 49.4 V Voc at 25 C, and 54.0 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 400.0 W

- **PTC Wattage** : 374.2 W

- **Voc @ 25C** : 49.4 V

- **Efficiency** : 20.54%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC400NP 72 XV Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC400NP 72 XV (Mono-c-Si) residential solar systems.

REC Group REC400NP 72 XV delivers 205.4 W/m2 (0.63 percentage points above 19.91% CEC median) and strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (419 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 55.31 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Boviet Solar Technology Co Ltd BVM6612M-400-H (400.0 W).

## Where Does REC Group REC400NP 72 XV Fall Across Listed CEC Models?

Comparison of REC Group REC400NP 72 XV (400.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define REC Group REC400NP 72 XV?

Relative ranking of REC Group REC400NP 72 XV across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for REC Group REC400NP 72 XV?

Summary of REC Group REC400NP 72 XV output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #9,407 / 21,677

### Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,364

### 20.54% Aperture Efficiency

Power density 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.0 V at -10 C (594.0 V string) and 55.31 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,000 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,484 W PTC; NEC 690.8 OCPD floor is 16.22 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.266/100) * (-10 - 25)) = 54.0 V | OCPD = 1.56 * 10.4 = 16.22 A

Inputs from CEC Modules.csv for REC Group REC400NP 72 XV: Voc=49.4 V, beta_Voc=-0.266%/C, Isc=10.4 A, STC=400.0 W, Area=1.947 m2.

**Result:** 11 panels max on 600 V (594.0 V); 20 panels for 8 kW (419 sq ft).

## What Are the Published CEC Specifications for REC Group REC400NP 72 XV?

Complete CEC test sheet for REC Group REC400NP 72 XV including Isc (10.4 A), Voc (49.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC400NP 72 XV.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 374.2 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.7 V / 9.84 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.266 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.54% (1.947 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC400NP 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC400NP 72 XV.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.0 kW | 314 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 20 | 8.0 kW | 419 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 25 | 10.0 kW | 524 sq ft | $2,503 | $4,232 |

## How Many REC Group REC400NP 72 XV Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC400NP 72 XV (49.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.4V and beta_Voc=-0.266%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.31 V | 10 panels | 553.1 V | 18 panels |
| **-10 C (14 F)** | 54.0 V | 11 panels | 594.0 V | 18 panels |
| **0 C (32 F)** | 52.69 V | 11 panels | 579.6 V | 18 panels |
| **25 C (77 F STC)** | 49.4 V | 12 panels | 592.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC400NP 72 XV?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612M-400-H (400.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h/) Boviet Solar Technology Co Ltd | 405.0 W | +5.0 W | 49.45 V | 20.35% | 93.3% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc/) Boviet Solar Technology Co Ltd | 405.0 W | +5.0 W | 49.45 V | 19.95% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC400NP 72 XV?

Evaluate REC Group REC400NP 72 XV (400.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC400NP 72 XV reaches 55.31 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC400NP 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC400NP 72 XV 8 kW Residential Fit

Needs 20 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 374.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC400NP 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### How many REC Group REC400NP 72 XV panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC400NP 72 XV cold Voc rises from 49.4 V to 54.0 V (beta_Voc -0.266%/C), capping a 600 V string at 11 panels (594.0 V).

### How much roof area does an 8 kW array of REC Group REC400NP 72 XV need?

An 8 kW DC system uses 20 REC Group REC400NP 72 XV modules (8,000 W STC / 7,484 W PTC), covering roughly 419 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does REC Group REC400NP 72 XV compare against Boviet Solar Technology Co Ltd BVM6612M-400-H?

REC Group REC400NP 72 XV outputs 400.0 W STC (49.4 V Voc, rank #9,407 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-400-H delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare REC Group equipment, Boviet Solar Technology Co Ltd BVM6612M-400-H specs, utility payback rates, and NEC string calculators alongside REC Group REC400NP 72 XV.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)