title: "REC Group REC370NP 72 XV Specs (370.0W, 47.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec370np-72-xv/
description: "CEC datasheet for REC Group REC370NP 72 XV: 370.0W STC, 47.7V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# REC Group REC370NP 72 XV — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC370NP 72 XV is a 370.0 W STC (345.5 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.0% efficiency, 47.7 V Voc at 25 C, and 52.14 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 370.0 W

- **PTC Wattage** : 345.5 W

- **Voc @ 25C** : 47.7 V

- **Efficiency** : 19.0%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC370NP 72 XV Compare Against Peer CEC Listings?

Engineering position of REC Group REC370NP 72 XV (370.0 W STC) vs. CertainTeed CT370M00-04 across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, REC Group REC370NP 72 XV pairs strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677) with 47.7 V nominal Voc. An 8 kW residential build (8,140 W DC, 7,601 W PTC) saves ~$2,037/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CertainTeed CT370M00-04 offers a 370.0 W alternative.

## Where Does REC Group REC370NP 72 XV Fall Across Listed CEC Models?

Plots REC Group REC370NP 72 XV at 370.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define REC Group REC370NP 72 XV?

Benchmarks REC Group REC370NP 72 XV on STC wattage, thermal PTC/STC retention, and 19.0 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for REC Group REC370NP 72 XV?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC370NP 72 XV by REC Group.

Rank #11,697 / 21,677

### 370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,454

### 19.0% Aperture Efficiency

Power density 190.0 W/m2 (0.91 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.14 V at -10 C (573.5 V string) and 53.41 V at -20 C (11 max).

 8 kW Reference Array

### 22 Panels = 8,140 W STC

Occupies 42.8 m2 (461 sq ft) producing 7,601 W PTC; NEC 690.8 OCPD floor is 15.85 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.7 * (1 + (-0.266/100) * (-10 - 25)) = 52.14 V | OCPD = 1.56 * 10.16 = 15.85 A

Inputs from CEC Modules.csv for REC Group REC370NP 72 XV: Voc=47.7 V, beta_Voc=-0.266%/C, Isc=10.16 A, STC=370.0 W, Area=1.947 m2.

**Result:** 11 panels max on 600 V (573.5 V); 22 panels for 8 kW (461 sq ft).

## What Are the Published CEC Specifications for REC Group REC370NP 72 XV?

Laboratory test ratings recorded for REC Group REC370NP 72 XV (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC370NP 72 XV.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 345.5 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 39.3 V / 9.42 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.266 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.0% (1.947 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC370NP 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (461 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC370NP 72 XV.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.29 kW | 356 sq ft | $1,574 | $2,662 |
| **8 kW Class** | 22 | 8.14 kW | 461 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 28 | 10.36 kW | 587 sq ft | $2,593 | $4,385 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Sibling wattage bins and frame colors grouped with REC Group REC370NP 72 XV under REC Group to prevent duplicate spec pages.

Sibling CEC listings grouped into the REC Group REC370NP 72 XV wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC365NP 72 XV** | 365.0 W | 340.7 W | 47.4 V | 39.1 V | 18.75% |
| **REC Group REC370NP 72 XV** | 370.0 W | 345.5 W | 47.7 V | 39.3 V | 19.0% |

## How Many REC Group REC370NP 72 XV Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC370NP 72 XV (beta_Voc -0.266%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.7V and beta_Voc=-0.266%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.41 V | 11 panels | 587.5 V | 18 panels |
| **-10 C (14 F)** | 52.14 V | 11 panels | 573.5 V | 19 panels |
| **0 C (32 F)** | 50.87 V | 11 panels | 559.6 V | 19 panels |
| **25 C (77 F STC)** | 47.7 V | 12 panels | 572.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC370NP 72 XV?

Closest cross-brand CEC competitors to REC Group REC370NP 72 XV matched near 370.0 W STC and 47.7 V Voc, led by CertainTeed CT370M00-04.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CT370M00-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct370m00-04/) CertainTeed | 370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |
| [**Bluesun Solar Energy Tech CoLtd BSM370M-72**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-energy-tech-coltd/bluesun-solar-energy-tech-coltd-bsm370m-72/) Bluesun Solar Energy Tech CoLtd | 370.0 W | Tie (0 W) | 48.23 V | 19.07% | 91.9% |
| [**Caterpillar Inc PVC370MP03H**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc370mp03h/) Caterpillar Inc | 370.0 W | Tie (0 W) | 48.6 V | 19.11% | 94.1% |
| [**CertainTeed CT365M10-02**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct365m10-02/) CertainTeed | 365.0 W | -5.0 W | 47.66 V | 19.39% | 91.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC370NP 72 XV?

Evaluate REC Group REC370NP 72 XV (370.0 W STC, 47.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC370NP 72 XV reaches 53.41 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 461 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (461 sq ft).
- 2026 tax credit baseline: cash residential installs of REC Group REC370NP 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC370NP 72 XV 8 kW Residential Fit

Needs 22 modules (461 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT370M00-04.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 345.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC370NP 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for REC Group REC370NP 72 XV?

Multiplying REC Group REC370NP 72 XV's 10.16 A short-circuit current by 1.56 equals 15.85 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can REC Group REC370NP 72 XV pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.14 V cold Voc at 14 F and handles 10.16 A Isc; string inverters cap REC Group REC370NP 72 XV at 11 panels on 600 V.

### Is REC Group REC370NP 72 XV eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC370NP 72 XV rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

## Related Pages

Compare REC Group equipment, CertainTeed CT370M00-04 specs, utility payback rates, and NEC string calculators alongside REC Group REC370NP 72 XV.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)