Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC330TP2M is a 330.0 W STC (307.1 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 20.41% efficiency, 40.6 V Voc at 25 C, and 44.66 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 330.0 W

- **PTC Wattage** : 307.1 W

- **Voc @ 25C** : 40.6 V

- **Efficiency** : 20.41%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC330TP2M Compare Against Peer CEC Listings?

Engineering position of REC Group REC330TP2M (330.0 W STC) vs. CSI Solar Co Ltd CS3K-330MS across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, REC Group REC330TP2M pairs strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677) with 40.6 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,678 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3K-330MS offers a 330.0 W alternative.

## Where Does REC Group REC330TP2M Fall Across Listed CEC Models?

Plots REC Group REC330TP2M at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define REC Group REC330TP2M?

Benchmarks REC Group REC330TP2M on STC wattage, thermal PTC/STC retention, and 20.41 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for REC Group REC330TP2M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC330TP2M by REC Group.

Rank #14,165 / 21,677

### 330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,911

### 20.41% Aperture Efficiency

Power density 204.1 W/m2 (0.50 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.66 V at -10 C (580.6 V string) and 45.83 V at -20 C (13 max).

 8 kW Reference Array

### 25 Panels = 8,250 W STC

Occupies 40.4 m2 (435 sq ft) producing 7,678 W PTC; NEC 690.8 OCPD floor is 15.94 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.6 * (1 + (-0.286/100) * (-10 - 25)) = 44.66 V | OCPD = 1.56 * 10.22 = 15.94 A

Inputs from CEC Modules.csv for REC Group REC330TP2M: Voc=40.6 V, beta_Voc=-0.286%/C, Isc=10.22 A, STC=330.0 W, Area=1.617 m2.

**Result:** 13 panels max on 600 V (580.6 V); 25 panels for 8 kW (435 sq ft).

## What Are the Published CEC Specifications for REC Group REC330TP2M?

Laboratory test ratings recorded for REC Group REC330TP2M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC330TP2M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 307.1 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.22 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.3 V / 9.62 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.286 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.41% (1.617 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many REC Group REC330TP2M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (435 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC330TP2M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 19 | 6.27 kW | 331 sq ft | $1,569 | $2,654 |
| **8 kW Class** | 25 | 8.25 kW | 435 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 31 | 10.23 kW | 540 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Sibling wattage bins and frame colors grouped with REC Group REC330TP2M under REC Group to prevent duplicate spec pages.

Sibling CEC listings grouped into the REC Group REC330TP2M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC325TP2M** | 325.0 W | 302.3 W | 40.4 V | 34.0 V | 20.1% |
| **REC Group REC325TP2M BLK** | 325.0 W | 302.3 W | 40.4 V | 34.0 V | 20.1% |
| **REC Group REC330TP2M** | 330.0 W | 307.1 W | 40.6 V | 34.3 V | 20.41% |
| **REC Group REC330TP2M BLK** | 330.0 W | 307.1 W | 40.6 V | 34.3 V | 20.41% |

## How Many REC Group REC330TP2M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC330TP2M (beta_Voc -0.286%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.6V and beta_Voc=-0.286%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.83 V | 13 panels | 595.8 V | 21 panels |
| **-10 C (14 F)** | 44.66 V | 13 panels | 580.6 V | 22 panels |
| **0 C (32 F)** | 43.5 V | 13 panels | 565.5 V | 22 panels |
| **25 C (77 F STC)** | 40.6 V | 14 panels | 568.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC330TP2M?

Closest cross-brand CEC competitors to REC Group REC330TP2M matched near 330.0 W STC and 40.6 V Voc, led by CSI Solar Co Ltd CS3K-330MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3K-330MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3k-330ms/) CSI Solar Co Ltd | 330.0 W | Tie (0 W) | 40.5 V | 20.62% | 93.2% |
| [**CertainTeed CT330HC11-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct330hc11-04/) CertainTeed | 330.0 W | Tie (0 W) | 40.27 V | 19.64% | 90.8% |
| [**Boviet Solar Technology Co Ltd BVM6610M-330L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-330l-h/) Boviet Solar Technology Co Ltd | 330.0 W | Tie (0 W) | 41.9 V | 19.76% | 93.6% |
| [**Boviet Solar Technology Co Ltd BVM6610M-330-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-330-h/) Boviet Solar Technology Co Ltd | 330.0 W | Tie (0 W) | 41.95 V | 20.25% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC330TP2M?

Evaluate REC Group REC330TP2M (330.0 W STC, 40.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC330TP2M reaches 45.83 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 435 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (435 sq ft).
- 2026 tax credit baseline: cash residential installs of REC Group REC330TP2M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC330TP2M 8 kW Residential Fit

Needs 25 modules (435 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3K-330MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 307.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC330TP2M by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for REC Group REC330TP2M?

Multiplying REC Group REC330TP2M's 10.22 A short-circuit current by 1.56 equals 15.94 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can REC Group REC330TP2M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.66 V cold Voc at 14 F and handles 10.22 A Isc; string inverters cap REC Group REC330TP2M at 13 panels on 600 V.

### Is REC Group REC330TP2M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC330TP2M rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare REC Group equipment, CSI Solar Co Ltd CS3K-330MS specs, utility payback rates, and NEC string calculators alongside REC Group REC330TP2M.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)