# REC Group REC300TP2 BLK — CEC Solar Module Specifications

Manufacturer: [**REC Group**](https://epri-peac.com/solar-equipment/brands/rec-group/) Registry: **CEC Verified Engineering Specification**

REC Group REC300TP2 BLK is a 300.0 W STC (277.4 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.52% efficiency, 39.2 V Voc at 25 C, and 43.15 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 277.4 W

- **Voc @ 25C** : 39.2 V

- **Efficiency** : 18.52%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does REC Group REC300TP2 BLK Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC300TP2 BLK (Multi-c-Si) residential solar systems.

Homeowners evaluating REC Group REC300TP2 BLK need 20 panels for 6 kW or 27 panels (471 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (471 sq ft). Under NEC 690.7(A), beta_Voc (-0.288%/C) pushes open-circuit voltage to 43.15 V at 14 F and 44.28 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does REC Group REC300TP2 BLK Fall Across Listed CEC Models?

Comparison of REC Group REC300TP2 BLK (300.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define REC Group REC300TP2 BLK?

Relative ranking of REC Group REC300TP2 BLK across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for REC Group REC300TP2 BLK?

Summary of REC Group REC300TP2 BLK output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #14,323

### 18.52% Aperture Efficiency

Power density 185.2 W/m2 (1.39 percentage points below 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.15 V at -10 C (560.9 V string) and 44.28 V at -20 C (13 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 43.7 m2 (471 sq ft) producing 7,490 W PTC; NEC 690.8 OCPD floor is 15.32 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.2 * (1 + (-0.288/100) * (-10 - 25)) = 43.15 V | OCPD = 1.56 * 9.82 = 15.32 A

Inputs from CEC Modules.csv for REC Group REC300TP2 BLK: Voc=39.2 V, beta_Voc=-0.288%/C, Isc=9.82 A, STC=300.0 W, Area=1.62 m2.

**Result:** 13 panels max on 600 V (560.9 V); 27 panels for 8 kW (471 sq ft).

## What Are the Published CEC Specifications for REC Group REC300TP2 BLK?

Complete CEC test sheet for REC Group REC300TP2 BLK including Isc (9.82 A), Voc (39.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC300TP2 BLK.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 277.4 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.82 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.5 V / 9.24 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.288 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.52% (1.62 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many REC Group REC300TP2 BLK Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC300TP2 BLK.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 349 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 471 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 593 sq ft | $2,553 | $4,317 |

## Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC300TP2 BLK series guide.

Sibling CEC listings grouped into the REC Group REC300TP2 BLK wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **REC Group REC300TP2** | 300.0 W | 277.4 W | 39.2 V | 32.5 V | 18.52% |
| **REC Group REC300TP2 BLK** | 300.0 W | 277.4 W | 39.2 V | 32.5 V | 18.52% |

## How Many REC Group REC300TP2 BLK Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC300TP2 BLK (39.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=39.2V and beta_Voc=-0.288%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.28 V | 13 panels | 575.6 V | 22 panels |
| **-10 C (14 F)** | 43.15 V | 13 panels | 560.9 V | 23 panels |
| **0 C (32 F)** | 42.02 V | 14 panels | 588.3 V | 23 panels |
| **25 C (77 F STC)** | 39.2 V | 15 panels | 588.0 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to REC Group REC300TP2 BLK?

Four comparable CEC modules such as CertainTeed CT300M10-01 (300.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CT300M10-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m10-01/) CertainTeed | 300.0 W | Tie (0 W) | 39.1 V | 18.33% | 91.0% |
| [**CertainTeed CT300M11-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m11-01/) CertainTeed | 300.0 W | Tie (0 W) | 39.1 V | 18.33% | 90.1% |
| [**FreeVolt PV-GRAF-60M6-300/M**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-pv-graf-60m6-300-m/) FreeVolt | 300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| [**Enphase Energy Inc XACM-IQ7-LR6-60PB-300M**](https://epri-peac.com/solar-equipment/modules/enphase-energy-inc/enphase-energy-inc-xacm-iq7-lr6-60pb-300m/) Enphase Energy Inc | 300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for REC Group REC300TP2 BLK?

Evaluate REC Group REC300TP2 BLK (300.0 W STC, 39.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC300TP2 BLK reaches 44.28 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 471 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (471 sq ft).
- 2026 tax credit baseline: cash residential installs of REC Group REC300TP2 BLK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### REC Group REC300TP2 BLK 8 kW Residential Fit

Needs 27 modules (471 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT300M10-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 277.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC300TP2 BLK by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is REC Group REC300TP2 BLK PTC wattage (277.4 W) lower than STC (300.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 277.4 W PTC (92.5% retention) across REC Group REC300TP2 BLK's 1.62 m2 aperture.

### Who should skip REC Group REC300TP2 BLK on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 REC Group REC300TP2 BLK panels (471 sq ft) leave unusable roof gaps vs. CertainTeed CT300M10-01.

### What is the 1,000 V commercial string limit for REC Group REC300TP2 BLK?

On 1,000 V commercial inverters at -10 C (43.15 V cold Voc), REC Group REC300TP2 BLK fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting REC Group REC300TP2 BLK.

## Related Pages

Compare REC Group equipment, CertainTeed CT300M10-01 specs, utility payback rates, and NEC string calculators alongside REC Group REC300TP2 BLK.

[All REC Group Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rec-group/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From REC Group

- [All REC Group Specs](https://epri-peac.com/solar-equipment/brands/rec-group/)
- [REC Group REC740AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec740aa-pro-xl/)
- [REC Group REC720AA Pro XL](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec720aa-pro-xl/)
- [REC Group REC680AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec680aa-pro-l/)
- [REC Group REC660AA Pro L](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec660aa-pro-l/)
- [REC Group REC640AA Pro M](https://epri-peac.com/solar-equipment/modules/rec-group/rec-group-rec640aa-pro-m/)