---
title: "Rayzon Solar Limited RS600132TGC Specs (600.0W, 48.09V Voc)"
url: https://epri-peac.com/solar-equipment/modules/rayzon-solar-limited/rayzon-solar-limited-rs600132tgc/
description: "CEC datasheet for Rayzon Solar Limited RS600132TGC: 600.0W STC, 48.09V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Rayzon Solar Limited RS600132TGC — CEC Solar Module Specifications

Manufacturer: [**Rayzon Solar Limited**](https://epri-peac.com/solar-equipment/brands/rayzon-solar-limited/) Registry: **CEC Verified Engineering Specification**

Rayzon Solar Limited RS600132TGC is a 600.0 W STC (569.8 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 22.22% efficiency, 48.09 V Voc at 25 C, and 52.01 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 600.0 W

- **PTC Wattage** : 569.8 W

- **Voc @ 25C** : 48.09 V

- **Efficiency** : 22.22%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Rayzon Solar Limited RS600132TGC Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Rayzon Solar Limited RS600132TGC (Mono-c-Si) residential solar systems.

Homeowners evaluating Rayzon Solar Limited RS600132TGC need 10 panels for 6 kW or 14 panels (407 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.233%/C) pushes open-circuit voltage to 52.01 V at 14 F and 53.13 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does Rayzon Solar Limited RS600132TGC Fall Across Listed CEC Models?

Comparison of Rayzon Solar Limited RS600132TGC (600.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Rayzon Solar Limited RS600132TGC?

Relative ranking of Rayzon Solar Limited RS600132TGC across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Rayzon Solar Limited RS600132TGC?

Summary of Rayzon Solar Limited RS600132TGC output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,320 / 21,677

### Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,585

### 22.22% Aperture Efficiency

Power density 222.2 W/m2 (2.31 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.01 V at -10 C (572.1 V string) and 53.13 V at -20 C (11 max).

 8 kW Reference Array

### 14 Panels = 8,400 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,977 W PTC; NEC 690.8 OCPD floor is 24.35 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.09 * (1 + (-0.233/100) * (-10 - 25)) = 52.01 V | OCPD = 1.56 * 15.61 = 24.35 A

Inputs from CEC Modules.csv for Rayzon Solar Limited RS600132TGC: Voc=48.09 V, beta_Voc=-0.233%/C, Isc=15.61 A, STC=600.0 W, Area=2.7 m2.

**Result:** 11 panels max on 600 V (572.1 V); 14 panels for 8 kW (407 sq ft).

## What Are the Published CEC Specifications for Rayzon Solar Limited RS600132TGC?

Complete CEC test sheet for Rayzon Solar Limited RS600132TGC including Isc (15.61 A), Voc (48.09 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Rayzon Solar Limited RS600132TGC.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 569.8 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.09 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 15.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.69 V / 14.76 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.233 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.22% (2.7 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Rayzon Solar Limited RS600132TGC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Rayzon Solar Limited RS600132TGC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.0 kW | 291 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 14 | 8.4 kW | 407 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 17 | 10.2 kW | 494 sq ft | $2,553 | $4,317 |

## How Many Rayzon Solar Limited RS600132TGC Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Rayzon Solar Limited RS600132TGC (48.09 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.09V and beta_Voc=-0.233%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.13 V | 11 panels | 584.4 V | 18 panels |
| **-10 C (14 F)** | 52.01 V | 11 panels | 572.1 V | 19 panels |
| **0 C (32 F)** | 50.89 V | 11 panels | 559.8 V | 19 panels |
| **25 C (77 F STC)** | 48.09 V | 12 panels | 577.1 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS600132TGC?

Four comparable CEC modules such as JA Solar JAM66D45-610/LB (610.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**JA Solar JAM66D45-610/LB**](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/) JA Solar | 610.0 W | +10.0 W | 48.1 V | 23.11% | 93.9% |
| [**CSI Solar Co Ltd CS62-66TB-610H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs62-66tb-610h/) CSI Solar Co Ltd | 610.0 W | +10.0 W | 48.0 V | 23.28% | 95.1% |
| [**CSI Solar Co Ltd CS62-66TB-610HP**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs62-66tb-610hp/) CSI Solar Co Ltd | 610.0 W | +10.0 W | 48.0 V | 23.28% | 95.1% |
| [**Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm8611m-610r-h-hc-bf/) Boviet Solar Technology Co Ltd | 610.0 W | +10.0 W | 48.25 V | 24.21% | 95.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS600132TGC?

Evaluate Rayzon Solar Limited RS600132TGC (600.0 W STC, 48.09 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS600132TGC reaches 53.13 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS600132TGC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Rayzon Solar Limited RS600132TGC 8 kW Residential Fit

Needs 14 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare JA Solar JAM66D45-610/LB.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 569.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Rayzon Solar Limited RS600132TGC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Rayzon Solar Limited RS600132TGC PTC wattage (569.8 W) lower than STC (600.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 569.8 W PTC (95.0% retention) across Rayzon Solar Limited RS600132TGC's 2.7 m2 aperture.

### Who should skip Rayzon Solar Limited RS600132TGC on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Rayzon Solar Limited RS600132TGC panels (407 sq ft) leave unusable roof gaps vs. JA Solar JAM66D45-610/LB.

### What is the 1,000 V commercial string limit for Rayzon Solar Limited RS600132TGC?

On 1,000 V commercial inverters at -10 C (52.01 V cold Voc), Rayzon Solar Limited RS600132TGC fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Rayzon Solar Limited RS600132TGC.

## Related Pages

Compare Rayzon Solar Limited equipment, JA Solar JAM66D45-610/LB specs, utility payback rates, and NEC string calculators alongside Rayzon Solar Limited RS600132TGC.

[All Rayzon Solar Limited Certified Solar Models](https://epri-peac.com/solar-equipment/brands/rayzon-solar-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Rayzon Solar Limited

- [All Rayzon Solar Limited Specs](https://epri-peac.com/solar-equipment/brands/rayzon-solar-limited/)
- [Rayzon Solar Limited RS630132TGC](https://epri-peac.com/solar-equipment/modules/rayzon-solar-limited/rayzon-solar-limited-rs630132tgc/)
- [Rayzon Solar Limited RS625132TGC](https://epri-peac.com/solar-equipment/modules/rayzon-solar-limited/rayzon-solar-limited-rs625132tgc/)
- [Rayzon Solar Limited RS620132TGC](https://epri-peac.com/solar-equipment/modules/rayzon-solar-limited/rayzon-solar-limited-rs620132tgc/)
- [Rayzon Solar Limited RS615132TGC](https://epri-peac.com/solar-equipment/modules/rayzon-solar-limited/rayzon-solar-limited-rs615132tgc/)
- [Rayzon Solar Limited RS610132TGC](https://epri-peac.com/solar-equipment/modules/rayzon-solar-limited/rayzon-solar-limited-rs610132tgc/)
