title: "PT SURYA PERTAMA INDONESIA Specs (pt-surya-perta)"
url: https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-585-144mt-w/
description: "CEC datasheet for PT SURYA PERTAMA INDONESIA LP-585-144MT-W: 585.0W STC, 53.43V Voc, 14-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# PT SURYA PERTAMA INDONESIA LP-585-144MT-W — CEC Solar Module Specifications

Manufacturer: [**PT SURYA PERTAMA INDONESIA**](https://epri-peac.com/solar-equipment/brands/pt-surya-pertama-indonesia/) Registry: **CEC Verified Engineering Specification**

PT SURYA PERTAMA INDONESIA LP-585-144MT-W is a 585.0 W STC (556.4 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 53.43 V Voc at 25 C, and 58.24 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 585.0 W

- **PTC Wattage** : 556.4 W

- **Voc @ 25C** : 53.43 V

- **Efficiency** : 22.67%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does PT SURYA PERTAMA INDONESIA LP-585-144MT-W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT SURYA PERTAMA INDONESIA LP-585-144MT-W (Mono-c-Si) residential solar systems.

PT SURYA PERTAMA INDONESIA LP-585-144MT-W delivers 226.7 W/m2 (2.76 percentage points above 19.91% CEC median) and strong 95.1% PTC-to-STC heat retention (#713 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 59.61 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (585.0 W).

## Where Does PT SURYA PERTAMA INDONESIA LP-585-144MT-W Fall Across Listed CEC Models?

Comparison of PT SURYA PERTAMA INDONESIA LP-585-144MT-W (585.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Relative ranking of PT SURYA PERTAMA INDONESIA LP-585-144MT-W across nameplate watts, 95.1% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Summary of PT SURYA PERTAMA INDONESIA LP-585-144MT-W output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,751 / 21,677

### Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,698

### 22.67% Aperture Efficiency

Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.24 V at -10 C (582.4 V string) and 59.61 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,190 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,790 W PTC; NEC 690.8 OCPD floor is 20.65 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.43 * (1 + (-0.257/100) * (-10 - 25)) = 58.24 V | OCPD = 1.56 * 13.24 = 20.65 A

Inputs from CEC Modules.csv for PT SURYA PERTAMA INDONESIA LP-585-144MT-W: Voc=53.43 V, beta_Voc=-0.257%/C, Isc=13.24 A, STC=585.0 W, Area=2.58 m2.

**Result:** 10 panels max on 600 V (582.4 V); 14 panels for 8 kW (389 sq ft).

## What Are the Published CEC Specifications for PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Complete CEC test sheet for PT SURYA PERTAMA INDONESIA LP-585-144MT-W including Isc (13.24 A), Voc (53.43 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PT SURYA PERTAMA INDONESIA LP-585-144MT-W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 556.4 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.43 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 46.6 V / 12.55 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.257 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.67% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many PT SURYA PERTAMA INDONESIA LP-585-144MT-W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT SURYA PERTAMA INDONESIA LP-585-144MT-W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| **8 kW Class** | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |

## Which Sibling Wattage & Trim Variants Belong to This PT SURYA PERTAMA INDONESIA Series?

Related PT SURYA PERTAMA INDONESIA power steps and black/silver trims consolidated into this PT SURYA PERTAMA INDONESIA LP-585-144MT-W series guide.

Sibling CEC listings grouped into the PT SURYA PERTAMA INDONESIA LP-585-144MT-W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **PT SURYA PERTAMA INDONESIA LP-575-144MT-W** | 575.0 W | 546.7 W | 53.15 V | 46.33 V | 22.29% |
| **PT SURYA PERTAMA INDONESIA LP-580-144MT-W** | 580.0 W | 551.6 W | 53.29 V | 46.47 V | 22.48% |
| **PT SURYA PERTAMA INDONESIA LP-585-144MT-W** | 585.0 W | 556.4 W | 53.43 V | 46.6 V | 22.67% |
| **PT SURYA PERTAMA INDONESIA LP-590-144MT-W** | 590.0 W | 561.3 W | 53.57 V | 46.75 V | 22.87% |

## How Many PT SURYA PERTAMA INDONESIA LP-585-144MT-W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PT SURYA PERTAMA INDONESIA LP-585-144MT-W (53.43 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=53.43V and beta_Voc=-0.257%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.61 V | 10 panels | 596.1 V | 16 panels |
| **-10 C (14 F)** | 58.24 V | 10 panels | 582.4 V | 17 panels |
| **0 C (32 F)** | 56.86 V | 10 panels | 568.6 V | 17 panels |
| **25 C (77 F STC)** | 53.43 V | 11 panels | 587.7 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Four comparable CEC modules such as FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (585.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**FreeVolt ECP-PVGRAF-HC-BF585-144MT-B**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf585-144mt-b/) FreeVolt | 585.0 W | Tie (0 W) | 53.4 V | 22.67% | 95.1% |
| [**FreeVolt ECP-PVGRAF-HC-BF585-144MT-W**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-ecp-pvgraf-hc-bf585-144mt-w/) FreeVolt | 585.0 W | Tie (0 W) | 53.4 V | 22.67% | 95.1% |
| [**Allesun Industries Inc Allesun-585-78IIMBG**](https://epri-peac.com/solar-equipment/modules/allesun-industries-inc/allesun-industries-inc-allesun-585-78iimbg/) Allesun Industries Inc | 585.0 W | Tie (0 W) | 53.73 V | 20.97% | 94.0% |
| [**G-Star Pte Ltd GSD7G78M-585BT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd7g78m-585bt/) G-Star Pte Ltd | 585.0 W | Tie (0 W) | 53.73 V | 21.12% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Evaluate PT SURYA PERTAMA INDONESIA LP-585-144MT-W (585.0 W STC, 53.43 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), PT SURYA PERTAMA INDONESIA LP-585-144MT-W reaches 59.61 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of PT SURYA PERTAMA INDONESIA LP-585-144MT-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### PT SURYA PERTAMA INDONESIA LP-585-144MT-W 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FreeVolt ECP-PVGRAF-HC-BF585-144MT-B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT SURYA PERTAMA INDONESIA LP-585-144MT-W by PT SURYA PERTAMA INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.

### How many PT SURYA PERTAMA INDONESIA LP-585-144MT-W panels fit on a 600 V winter solar string?

At -10 C (14 F), PT SURYA PERTAMA INDONESIA LP-585-144MT-W cold Voc rises from 53.43 V to 58.24 V (beta_Voc -0.257%/C), capping a 600 V string at 10 panels (582.4 V).

### How much roof area does an 8 kW array of PT SURYA PERTAMA INDONESIA LP-585-144MT-W need?

An 8 kW DC system uses 14 PT SURYA PERTAMA INDONESIA LP-585-144MT-W modules (8,190 W STC / 7,790 W PTC), covering roughly 389 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

### How does PT SURYA PERTAMA INDONESIA LP-585-144MT-W compare against FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?

PT SURYA PERTAMA INDONESIA LP-585-144MT-W outputs 585.0 W STC (53.43 V Voc, rank #1,751 of 21,677), while FreeVolt ECP-PVGRAF-HC-BF585-144MT-B delivers 585.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare PT SURYA PERTAMA INDONESIA equipment, FreeVolt ECP-PVGRAF-HC-BF585-144MT-B specs, utility payback rates, and NEC string calculators alongside PT SURYA PERTAMA INDONESIA LP-585-144MT-W.

[All PT SURYA PERTAMA INDONESIA Certified Solar Models](https://epri-peac.com/solar-equipment/brands/pt-surya-pertama-indonesia/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From PT SURYA PERTAMA INDONESIA

- [All PT SURYA PERTAMA INDONESIA Specs](https://epri-peac.com/solar-equipment/brands/pt-surya-pertama-indonesia/)
- [PT SURYA PERTAMA INDONESIA LP-585-144MT-B](https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-585-144mt-b/)
- [PT SURYA PERTAMA INDONESIA LP-560-144MT-B](https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-560-144mt-b/)
- [PT SURYA PERTAMA INDONESIA LP-560-144MT-W](https://epri-peac.com/solar-equipment/modules/pt-surya-pertama-indonesia/pt-surya-pertama-indonesia-lp-560-144mt-w/)